Laserfiche WebLink
CITY SUBMITTAL <br />OCCUPANCY REQUIREMENTS <br />CLIENT APPROVALPROJECT GENERAL NOTES PROJECT GENERAL NOTES CONTINUED <br />---- <br />71 MINNESOTA AVE <br />LITTLE CANADA, MN 55117 <br />APPLICABLE CODES <br />08/22/2016 <br />CERTIFICATION <br />16127.0 TSB <br />PLUMBING REVIEW <br />CODE REVIEW <br />TRI-STATE BOBCAT <br />1200 HWY. 13 <br />BURNSVILLE, MN 55337 <br />AS A REPRESENTATIVE OF: <br />I ACCEPT AND APPROVE THE INFORMATION PRESENTED <br />IN THIS DRAWING SET AS A REPRESENTATION OF OUR <br />DESIGN INTENT. SHOULD OWNER INITIATE CHANGES <br />THAT RESULT IN REVISIONS AND/OR MODIFICATIONS <br />ADDITIONAL DESIGN SERVICE FEES WILL BE CHARGED. <br />TITLE: <br />I HEREBY CERTIFY THAT THIS PLAN, <br />SPECIFICATION OR REPORT WAS PREPARED BY <br />ME OR UNDER MY DIRECT SUPERVISION, AND <br />THAT I AM A DULY LICENSED ARCHITECT UNDER <br />THE LAWS OF THE STATE OF MINNESOTA. <br />TODD MOHAGEN, AIA, NCARB <br />REGISTRATION NUMBER:18074 <br />FIRE SPRINKLER PROTECTION: FULLY SPRINKLED <br />TYPE OF CONSTRUCTION: II-B <br />BUILDING OCCUPANCY: B, S, M <br />AREA MAP <br />TR <br />I <br />- <br />S <br />T <br />A <br />T <br />E <br /> <br />B <br />O <br />B <br />C <br />A <br />T <br />/ <br />1 <br />6 <br />1 <br />2 <br />7 <br />. <br />0 <br /> <br />T <br />S <br />B <br />/ <br />C <br />I <br />T <br />Y <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />/ <br />T <br />R <br />I <br />- <br />S <br />T <br />A <br />T <br />E <br /> <br />B <br />O <br />B <br />C <br />A <br />T <br />- <br /> <br />L <br />I <br />T <br />T <br />L <br />E <br /> <br />C <br />A <br />N <br />A <br />D <br />A <br />A301 <br />A302 <br />A201 <br />REVISED EXTERIOR ELEVATIONS <br />FLOOR PLAN <br />PERSPECTIVE VIEWS <br />A000 <br />C-1 <br />C-2 <br />C-0 <br />L2 <br />L1 <br />CIVIL <br />GRADING AND EROSION CONTROL PLAN <br />LANDSCAPE PLAN <br />EXISTING TREE SURVEY <br />TITLE SHEET, CODE REVIEW, AREA MAP <br />SITE AND UTILITY PLAN <br />EXISTING CONDITIONS <br />SHEET INDEX <br />INTERNATIONAL BUILDING CODE (IBC) 2012 <br />AMENDMENTS IN MSBC: CHAPTER 1300 2015 <br />AMENDMENTS IN MSBC: CHAPTER 1341 2015 <br />AMENDMENTS IN MSBC: CHAPTER 1307 2015 <br />INTERNATIONAL FIRE CODE (IFC) 2012 <br />INTERNATIONAL MECHANICAL AND FUEL GAS CODE 2012 <br />AMENDMENTS IN MSBC: CHAPTER 1346 2015 <br />STATE BUILDING CODE (MSBC) 2015 <br />MN PLUMBING CODE 2012 CHAP. 4715 <br />INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2012 W/ ASHRAE 90.1-2010 CRITERIA <br />AMENDMENTS IN MSBC: CHAPTER 1323 2015 <br />NATIONAL ELECTRICAL CODE 2014 <br />MN FIRE CODE 2007 <br />SITE LOCATION <br />ELECTRICAL <br />1. THE ELECTRICAL CONTRACTOR IS TO DESIGN ALL ELECTRICAL SYSTEMS AND OBTAIN <br />NECESSARY PERMITS. THE ELECTRICAL DESIGN IS TO BE COORDINATED WITH THE <br />ATTACHED ARCHITECTURAL CONSTRUCTION DOCUMENTS. THE ELECTRICAL DESIGN IS TO <br />BE REVIEWED BY THE ARCHITECT OF RECORD AND TENANT PRIOR TO IMPLEMENTATION. <br />2. THE ELECTRICAL CONTRACTOR IS TO COORDINATE THE INSTALLATION OF ALL MECHANICAL <br />EQUIPMENT AND TO PROVIDE DISCONNECT AND POWER WIRING FOR ALL MECHANICAL <br />EQUIPMENT. <br />3. THE ELECTRICAL CONTRACTOR IS TO PROVIDE EXIT AND EMERGENCY LIGHTS AS REQUIRED <br />BY APPLICABLE CODES AND ORDINANCES. <br />4. THE ELECTRICAL CONTRACTOR IS TO PROVIDE SMOKE DETECTION AND ALARM DEVICES <br />AND WIRING OF THE SPACE AS REQUIRED BY APPLICABLE CODES AND ORDINANCES FOR <br />THE INTERIOR BUILD-OUT SPACE. <br />5. THE ELECTRICAL CONTRACTOR SHALL INSTALL JUNCTION BOXES W/ PULL STRING FOR ALL <br />VOICE / DATA AND PHONE LOCATIONS. THE TENANT IS TO COORDINATE & PROVIDE ALL <br />LOW VOLTAGE CABLING AND COVER PLATES AS REQUIRED. <br />6. NEW ELECTRICAL OUTLETS ARE SHOWN AT APPROXIMATE LOCATIONS. NO OUTLETS ARE <br />TO BE BACK TO BACK. <br />7. ALL UNDER CABINET LIGHTING IS TO BE CONTROLLED BY A WALL SWITCH. <br />8. THE REFLECTED CEILING PLAN IS FOR REFERENCE ONLY REGARDING LOCATION, <br />QUANTITIES, AND TYPES OF LIGHT FIXTURES. THE REFLECTED CEILING PLAN REFERENCES <br />LIGHT FIXTURES, HOWEVER THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO VERIFY THE <br />FIXTURE TYPE, APPROPRIATE FOOTCANDLES AND VOLTAGE REQUIREMENTS OF ALL <br />SPECIFIED LIGHT FIXTURES IN ASSOCIATION W/ THE SPECIFIC SITE CONDITIONS AND <br />PROVIDE SHOP DRAWINGS FOR REVIEW & APPROVAL PRIOR TO THE ORDERING OR <br />INSTALLATION OF ANY FIXTURES. <br />MECHANICAL <br />1. THE MECHANICAL CONTRACTOR IS TO DESIGN ALL MECHANICAL SYSTEMS AND OBTAIN <br />NECESSARY PERMITS. MECHANICAL DOCUMENTS ARE TO BE PROVIDED BY THE <br />MECHANICAL CONTRACTOR AND SIGNED BY A PROFESSIONAL ENGINEER AS REQUIRED BY <br />CODE. THE MECHANICAL DESIGN IS TO BE COORDINATED WITH THE ATTACHED <br />ARCHITECTURAL CONSTRUCTION DOCUMENTS. THE DESIGN IS TO BE REVIEWED BY THE <br />TENANT PRIOR TO IMPLEMENTATION. <br />2. THE MECHANICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL NECESSARY MECHANICAL <br />EQUIPMENT AND CONTROLS TO COMPLETE THE JOB. THE MECHANICAL CONTRACTOR IS <br />TO COORDINATE W/ THE ELECTRICAL CONTRACTOR ALL THE NECESSARY WIRING TO <br />COMPLETE THE JOB. THE WIRING IS TO BE COMPLETED BY THE ELECTRICAL CONTRACTOR. <br />3. PROVIDE WHITE SEMI RECESSED SPRINKLER HEADS W/ WHITE TRIM RING @ ALL ACT. <br />CEILING AND FULLY RECESSED SPRINKLER HEADS W/ WHITE ESCUTCHEON PLATES @ ALL <br />GYP. CEILING AS REQUIRED BY APPLICABLE CODES AND ORDINANCES. <br />4. VERIFY LOCATION AND SIZES OF ALL OPENINGS WITH GENERAL CONTRACTOR PRIOR TO <br />COMMENCING WORK. THE GENERAL CONTRACTOR IS RESPONSIBLE TO CUT & PATCH OR <br />ADD STRUCTURAL REINFORCING AS REQ'D FOR THE INSTALLATION OF MECHANICAL <br />ROOFTOP EQUIPMENT. <br />5. ALL SINKS SHALL HAVE HOT AND COLD WATER WITH BELOW COUNTER PIPE INSULATION <br />WRAP ON EXPOSED PIPING PER ADA GUIDELINES. <br />6. PROVIDE AND INSTALL AN APPROPRIATE SIZED WATER HEATER AS REQUIRED. <br />FINISHES <br />1. THE CONTRACTOR SHALL PATCH AND REPAIR ANY AND ALL FLOORS, WALLS, CEILINGS, ETC. <br />IN A WORKMANSHIP-LIKE MANNER TO MATCH THE SURROUNDING SURFACE AREAS. <br />SURFACES OR MATERIALS DAMAGED BY DEMOLITION OR CONSTRUCTION SHALL BE <br />REPAIRED, RESTORED AND REFINISHED TO MATCH THE EXISTING, UNLESS NOTED OR <br />SPECIFIED OTHERWISE. IN ADDITION THOSE EXISTING SURFACES OR MATERIALS (SERVING <br />AS A SUBSTRATE FOR NEW MATERIALS OR FINISHES) WHICH HAVE BEEN DAMAGED FROM <br />ANY CAUSE, SHALL BE REPAIRED, RESTORED, PROPERLY PREPARED AND CLEANED TO <br />RECEIVE THE NEW MATERIALS AND FINISH WORK. ALL NEW MATERIALS & FINISH WORK TO <br />BE FREE FROM FLAWS & DEFECTS. <br />2. PATCH AND REPAIR EXISTING FLOOR SLAB AS REQUIRED FOR A SMOOTH AND LEVEL <br />SURFACE FREE OF DEFECTS. FILL ALL CRACKS AND HOLES AND LEVEL DEPRESSIONS WITH <br />MATERIALS COMPATIBLE WITH THE FLOOR AND SLAB AS RECOMMENDED BY THE <br />FLOORING MANUFACTURER. <br />3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING LEAD TIMES OF ALL <br />MATERIALS SUCH THAT MATERIALS ARE ON SITE WHEN REQUIRED FOR INSTALLATION. <br />4. ALL PREPARATION, STORING, INSTALLATION AND CLEANUP OF FINISHES TO CONFORM TO <br />MANUFACTURER'S SPECIFICATIONS. <br />5. ALL GRILLES, EXTINGUISHER CABINETS AND MISC. METALS SHALL BE PAINTED TO MATCH <br />THE SURFACE ON WHICH THEY OCCUR UNLESS NOTED OTHERWISE. <br />6. ALL HOLLOW METAL DOOR FRAMES TO BE PAINTED TO MATCH THE SURFACE ON WHICH <br />THEY OCCUR UNLESS NOTED OTHERWISE. <br />7. CERAMIC, PORCELAIN AND STONE FLOOR TILES TO BE INSTALLED WITH A BRASS OR ZINC 'L' <br />ANGLE DIVIDER STRIP @ ALL CARPET / FLOOR TILE TRANSITIONS. <br />8. WHERE VCT MEETS CARPET, A VINYL TRANSITION STRIP SHALL BE INSTALLED, VINYL STRIP <br />TO MATCH VCT COLOR UNLESS NOTED OTHERWISE. <br />9. PORCELAIN OR CERAMIC FLOOR TILE TRANSITIONS TO CARPET AT RESTROOM DOOR <br />ENTRIES SHALL HAVE A SOLID SURFACE MATERIAL (EX. CORIAN THRESHOLD) <br />ARCHITECTURAL <br />1. GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, (AIA DOCUMENT A201, <br />CURRENT EDITION) IN ITS ENTIRETY, ARE PART OF THESE DOCUMENTS. ADDITIONAL NOTES <br />WITHIN THESE DOCUMENTS ARE NOT MEANT TO OVERRIDE ANY PART OF A201. CONTACT <br />ARCHITECT FOR A COPY OF A201, IF REQUIRED. <br />2. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED PROJECT. UNLESS <br />OTHERWISE INDICATED, THEY DO NOT INDICATE THE MEANS OR METHOD OF CONSTRUCTION. <br />3. THE CONTRACTOR SHALL OBTAIN SUFFICIENT LIABILITY INSURANCE TO COVER WORKMAN'S <br />COMPENSATION, GENERAL LIABILITY AND CONTRACTUAL LIABILITY. A COPY SHALL BE FILED <br />WITH THE OWNER. <br />4. THE CONTRACTOR SHALL PROVIDE ALL WORK AND MATERIALS AS REQUIRED BY THE <br />CONSTRUCTION DOCUMENTS AND IN FULL ACCORDANCE WITH ALL APPLICABLE CODES AND <br />ORDINANCES. <br />5. THE CONTRACTOR WILL MAINTAIN BUILDER'S RISK INSURANCE ON THE FORM KNOWN AS "ALL <br />RISK" OR "MULTIPLE PERIL". THE CONTRACTOR, ALL SUBCONTRACTORS, ARCHITECTS AND <br />ENGINEERS SHALL BE INCLUDED IN EACH CAPACITY AS INSURED JOINTLY WITH THE OWNER IN <br />ALL POLICIES. <br />6. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND FIELD CONDITIONS PRIOR TO <br />ANY DEMOLITION, FABRICATION, CONSTRUCTION OR INSTALLATION & NOTIFY ARCHITECT IF <br />CONDITIONS, MATERIALS, SIZES AND DIMENSIONS ARE DIFFERENT FROM THOSE SHOWN. <br />7. CROSS REFERENCE ALL DIMENSIONS AND DETAILS WITH STRUCTURAL, CIVIL, MECHANICAL, <br />AND ELECTRICAL DRAWINGS BEFORE COMMENCING ANY FABRICATION AND/OR <br />CONSTRUCTION. <br />8. CONTRACTORS SHALL INSTALL ALL MANUFACTURED ITEMS, MATERIALS AND EQUIPMENT IN <br />STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT <br />WHERE THE SPECIFICATIONS HEREIN, ARE MORE STRINGENT, AND SHALL BE COMPLIED WITH. <br />9. MATERIALS WHICH ARE SHOWN ON THE DRAWINGS AND WHICH MAY NOT BE SPECIFICALLY <br />DESCRIBED IN THE SPECIFICATIONS OR DRAWINGS, SHALL BE FURNISHED BY THE <br />CONTRACTOR AND SHALL BE SUITABLE FOR THE INTENDED USE. MATERIALS SHALL BE IN <br />HARMONY WITH ADJACENT MATERIALS, AND SHALL BE SUBJECT TO REVIEW FOR <br />CONFORMANCE WITH THE INTENT OF THE CONTRACT DOCUMENTS. WHERE INSTALLATION <br />TECHNIQUES ARE NOT SPECIFIED, THEY SHALL BE IN ACCORDANCE WITH MANUFACTURER'S <br />CURRENT INSTRUCTION AND INDUSTRY STANDARDS. <br />10. SHOP DRAWINGS PREPARED BY SUPPLIERS, SUBCONTRACTORS, ETC. SHALL BE REVIEWED, <br />COORDINATED AND SIGNED AND STAMPED BY GENERAL CONTRACTOR PRIOR TO SUBMITTING <br />TO THE ARCHITECT/ENGINEER. <br />11. THE CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS, LICENSES AND CERTIFICATES AND <br />PAY ALL FEES CONNECTED THEREWITH THE ABOVE REFERENCED PROJECT. <br />12. THE CONTRACTOR SHALL BE RESPONSIBLE TO PREPARE ALL SURFACES FOR PROPER <br />INSTALLATION OF FINISHES. THIS IS TO INCLUDE, BUT IS NOT LIMITED TO: PATCHING, <br />SANDING, FLOOR LEVELING, PRIMING, SEALING, SKIM COATING, ETC. <br />13. THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES FREE FROM WASTE MATERIAL OR <br />RUBBISH CAUSED BY THE WORK. <br />14. THE CONTRACTOR SHALL MINIMIZE ANY DAMAGE TO EXISTING CONSTRUCTION AND AREAS <br />ON THE SITE OUTSIDE OF THE CONSTRUCTION LIMITS. CONTRACTOR TO CONSTRUCT <br />TEMPORARY WALLS AND BARRIERS AS REQUIRED TO CONTAIN DUST AND DEBRIS AND TO <br />PROVIDE SAFE PUBLIC ACCESS AND PASSAGE. <br />15. THE GENERAL CONTRACTOR SHALL LOCATE ALL NEW MECHANICAL UNITS OR RELOCATE ANY <br />EXISTING UNITS OR ITEMS THAT CONFLICT WITH NEW OR EXISTING FRAMING AND FULL <br />HEIGHT WALLS. THIS INCLUDES ACCESS FOR ALL CONTROLS, FILTERS, ETC. THIS WORK MUST <br />BE COORDINATED AND VERIFIED PRIOR TO BIDDING. <br />16. THE GENERAL CONTRACTOR SHALL COORDINATE AND VERIFY WITH THE RESPECTIVE TRADES <br />THE SIZES AND LOCATIONS OF MECHANICAL AND/OR ELECTRICAL PENETRATIONS, LOCATIONS <br />OF FIRE TREATED BACKING/BLOCKING REQUIRED FOR MOUNTING ELECTRICAL AND/OR <br />MECHANICAL EQUIPMENT, AS WELL AS CUTTING AND PATCHING FOR WORK REQUIRED BY <br />MECHANICAL/ELECTRICAL. <br />17. WHEN WORK IS COMPLETED IN AN AREA, THOROUGHLY CLEAN THE SPACES, ITEMS & <br />SURFACES OF SOIL, WASTE MATERIAL, SMUDGES, SPATTERS, MISAPPLIED MATERIAL, SPOTS, <br />STAINS, AND THE LIKE, WITHOUT DAMAGING THE MATERIALS AND SURFACES INVOLVED. <br />18. PROVIDE SEMI RECESSED FIRE EXTINGUISHERS AS REQUIRED BY APPLICABLE CODES AND <br />ORDINANCES UNLESS NOTED OTHERWISE. <br />19. ALL DOORS, FRAMES, HARDWARE, LIGHTING AND CEILING MATERIALS ARE TO FOLLOW <br />BUILDING STANDARDS UNLESS OTHERWISE NOTED. <br />20. PROVIDE FIRE TREATED BLOCKING IN WALLS AS REQUIRED FOR INSTALLATION OF MILLWORK, <br />FURNITURE AND ACCESSORIES. <br />21. THE GENERAL CONTRACTOR IS TO VERIFY BUILDING STANDARDS WITH BUILDING MANAGER. <br />ALL HARDWARE SETS AND KEYING TO BE COORDINATED WITH BUILDING MANAGERS. <br />22. ALL INTERIOR GLASS MUST COMPLY W/ APPLICABLE CODES FOR DESIGN LOADS & SAFETY <br />GLAZING. <br />23. ALL MATERIALS USED IN PLENUM AREAS MUST BE NON-COMBUSTIBLE AND / OR LISTED FOR <br />PLENUM USE AS DEFINED BY THE STATE & LOCAL CODES. IT WILL BE THE CONTRACTORS <br />RESPONSIBILITY TO ADHERE TO THESE REQUIREMENTS. <br />24. THE GENERAL CONTRACTOR WILL BE RESPONSIBLE TO FIRE CAULK ALL NEW AND EXISTING <br />PENETRATIONS WITHIN WALL PARTITIONS, ABOVE THE CEILING, AS INDICATED BY THE <br />APPLICABLE CODES. <br />SHEET # SHEET DESCRIPTION NOTES <br />BUILDING USE TYPE SQ. FEET OCC. <br />FACTOR OCC. LOAD 2 EXITS <br />REQ'D <br />OFFICE B 2,315 100 23.15 <br />SHOWROOM M 10,543 30 351.43 - <br />SERVICE S-1 13,357 100 133.57 - <br />WAREHOUSE S-1 9,865 300 32.88 <br />TOTAL 541.04 - <br />CLASSIFICA- <br />TION OCC. <br />OCC. <br />LOAD/ <br />2 <br />WATER CLOSETS LAVATORIES <br />REQ'D <br />M <br />PROV. <br />M <br />REQ'D <br />W <br />PROV. <br />W <br />REQ'D <br />M <br />PROV. <br />M <br />REQ'D <br />W <br />PROV. <br />W <br />OFFICE B 13 <br />1/25<50 <br />- <br />1/25<50 <br />- <br />1/40<80 <br />- <br />1/40<80 <br />-.46 .46 -- <br />1/50>50 1/50>50 1/80>80 1/80>80 <br />---- <br />FACTORY & <br />INDUSTRIAL F 67 1/100 - 1/100 - 1/100 - 1/100 -0.67 0.67 0.67 0.67 <br />MERCANTILE M 176 1/500 - 1/500 - 1/750 - 1/750 -0.35 0.35 0.23 0.23 <br />STORAGE S 17 1/100 - 1/100 - 1/100 - 1/100 -0.17 0.17 0.17 0.17 <br />TOTAL 1.65 2 1.65 2 1.07 2 1.07 2 <br />LANDSCAPE <br />ARCHITECTURAL <br />HWY 35E <br />HWY 36 <br />RICE <br />PARKING: <br />STORAGE: 9,865 SF/500 = 19.7 <br />OFFICE: 2,315 SF/200 = 23.2 <br />SHOWROOM: 10,543 SF/200 = 52.7 <br />SHOP: 13,357 SF/500 = 26.7 <br />TOTAL PARKING = 111 <br />PARKING PROVIDED: <br />84 CUSTOMER, 6 DELIVERY/ DROP-OFF, 26 EMPLOYEE = 116 TOTAL PROVIDED