CITY SUBMITTAL
<br />OCCUPANCY REQUIREMENTS
<br />CLIENT APPROVALPROJECT GENERAL NOTES PROJECT GENERAL NOTES CONTINUED
<br />----
<br />71 MINNESOTA AVE
<br />LITTLE CANADA, MN 55117
<br />APPLICABLE CODES
<br />08/22/2016
<br />CERTIFICATION
<br />16127.0 TSB
<br />PLUMBING REVIEW
<br />CODE REVIEW
<br />TRI-STATE BOBCAT
<br />1200 HWY. 13
<br />BURNSVILLE, MN 55337
<br />AS A REPRESENTATIVE OF:
<br />I ACCEPT AND APPROVE THE INFORMATION PRESENTED
<br />IN THIS DRAWING SET AS A REPRESENTATION OF OUR
<br />DESIGN INTENT. SHOULD OWNER INITIATE CHANGES
<br />THAT RESULT IN REVISIONS AND/OR MODIFICATIONS
<br />ADDITIONAL DESIGN SERVICE FEES WILL BE CHARGED.
<br />TITLE:
<br />I HEREBY CERTIFY THAT THIS PLAN,
<br />SPECIFICATION OR REPORT WAS PREPARED BY
<br />ME OR UNDER MY DIRECT SUPERVISION, AND
<br />THAT I AM A DULY LICENSED ARCHITECT UNDER
<br />THE LAWS OF THE STATE OF MINNESOTA.
<br />TODD MOHAGEN, AIA, NCARB
<br />REGISTRATION NUMBER:18074
<br />FIRE SPRINKLER PROTECTION: FULLY SPRINKLED
<br />TYPE OF CONSTRUCTION: II-B
<br />BUILDING OCCUPANCY: B, S, M
<br />AREA MAP
<br />TR
<br />I
<br />-
<br />S
<br />T
<br />A
<br />T
<br />E
<br />
<br />B
<br />O
<br />B
<br />C
<br />A
<br />T
<br />/
<br />1
<br />6
<br />1
<br />2
<br />7
<br />.
<br />0
<br />
<br />T
<br />S
<br />B
<br />/
<br />C
<br />I
<br />T
<br />Y
<br />
<br />S
<br />U
<br />B
<br />M
<br />I
<br />T
<br />T
<br />A
<br />L
<br />/
<br />T
<br />R
<br />I
<br />-
<br />S
<br />T
<br />A
<br />T
<br />E
<br />
<br />B
<br />O
<br />B
<br />C
<br />A
<br />T
<br />-
<br />
<br />L
<br />I
<br />T
<br />T
<br />L
<br />E
<br />
<br />C
<br />A
<br />N
<br />A
<br />D
<br />A
<br />A301
<br />A302
<br />A201
<br />REVISED EXTERIOR ELEVATIONS
<br />FLOOR PLAN
<br />PERSPECTIVE VIEWS
<br />A000
<br />C-1
<br />C-2
<br />C-0
<br />L2
<br />L1
<br />CIVIL
<br />GRADING AND EROSION CONTROL PLAN
<br />LANDSCAPE PLAN
<br />EXISTING TREE SURVEY
<br />TITLE SHEET, CODE REVIEW, AREA MAP
<br />SITE AND UTILITY PLAN
<br />EXISTING CONDITIONS
<br />SHEET INDEX
<br />INTERNATIONAL BUILDING CODE (IBC) 2012
<br />AMENDMENTS IN MSBC: CHAPTER 1300 2015
<br />AMENDMENTS IN MSBC: CHAPTER 1341 2015
<br />AMENDMENTS IN MSBC: CHAPTER 1307 2015
<br />INTERNATIONAL FIRE CODE (IFC) 2012
<br />INTERNATIONAL MECHANICAL AND FUEL GAS CODE 2012
<br />AMENDMENTS IN MSBC: CHAPTER 1346 2015
<br />STATE BUILDING CODE (MSBC) 2015
<br />MN PLUMBING CODE 2012 CHAP. 4715
<br />INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2012 W/ ASHRAE 90.1-2010 CRITERIA
<br />AMENDMENTS IN MSBC: CHAPTER 1323 2015
<br />NATIONAL ELECTRICAL CODE 2014
<br />MN FIRE CODE 2007
<br />SITE LOCATION
<br />ELECTRICAL
<br />1. THE ELECTRICAL CONTRACTOR IS TO DESIGN ALL ELECTRICAL SYSTEMS AND OBTAIN
<br />NECESSARY PERMITS. THE ELECTRICAL DESIGN IS TO BE COORDINATED WITH THE
<br />ATTACHED ARCHITECTURAL CONSTRUCTION DOCUMENTS. THE ELECTRICAL DESIGN IS TO
<br />BE REVIEWED BY THE ARCHITECT OF RECORD AND TENANT PRIOR TO IMPLEMENTATION.
<br />2. THE ELECTRICAL CONTRACTOR IS TO COORDINATE THE INSTALLATION OF ALL MECHANICAL
<br />EQUIPMENT AND TO PROVIDE DISCONNECT AND POWER WIRING FOR ALL MECHANICAL
<br />EQUIPMENT.
<br />3. THE ELECTRICAL CONTRACTOR IS TO PROVIDE EXIT AND EMERGENCY LIGHTS AS REQUIRED
<br />BY APPLICABLE CODES AND ORDINANCES.
<br />4. THE ELECTRICAL CONTRACTOR IS TO PROVIDE SMOKE DETECTION AND ALARM DEVICES
<br />AND WIRING OF THE SPACE AS REQUIRED BY APPLICABLE CODES AND ORDINANCES FOR
<br />THE INTERIOR BUILD-OUT SPACE.
<br />5. THE ELECTRICAL CONTRACTOR SHALL INSTALL JUNCTION BOXES W/ PULL STRING FOR ALL
<br />VOICE / DATA AND PHONE LOCATIONS. THE TENANT IS TO COORDINATE & PROVIDE ALL
<br />LOW VOLTAGE CABLING AND COVER PLATES AS REQUIRED.
<br />6. NEW ELECTRICAL OUTLETS ARE SHOWN AT APPROXIMATE LOCATIONS. NO OUTLETS ARE
<br />TO BE BACK TO BACK.
<br />7. ALL UNDER CABINET LIGHTING IS TO BE CONTROLLED BY A WALL SWITCH.
<br />8. THE REFLECTED CEILING PLAN IS FOR REFERENCE ONLY REGARDING LOCATION,
<br />QUANTITIES, AND TYPES OF LIGHT FIXTURES. THE REFLECTED CEILING PLAN REFERENCES
<br />LIGHT FIXTURES, HOWEVER THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO VERIFY THE
<br />FIXTURE TYPE, APPROPRIATE FOOTCANDLES AND VOLTAGE REQUIREMENTS OF ALL
<br />SPECIFIED LIGHT FIXTURES IN ASSOCIATION W/ THE SPECIFIC SITE CONDITIONS AND
<br />PROVIDE SHOP DRAWINGS FOR REVIEW & APPROVAL PRIOR TO THE ORDERING OR
<br />INSTALLATION OF ANY FIXTURES.
<br />MECHANICAL
<br />1. THE MECHANICAL CONTRACTOR IS TO DESIGN ALL MECHANICAL SYSTEMS AND OBTAIN
<br />NECESSARY PERMITS. MECHANICAL DOCUMENTS ARE TO BE PROVIDED BY THE
<br />MECHANICAL CONTRACTOR AND SIGNED BY A PROFESSIONAL ENGINEER AS REQUIRED BY
<br />CODE. THE MECHANICAL DESIGN IS TO BE COORDINATED WITH THE ATTACHED
<br />ARCHITECTURAL CONSTRUCTION DOCUMENTS. THE DESIGN IS TO BE REVIEWED BY THE
<br />TENANT PRIOR TO IMPLEMENTATION.
<br />2. THE MECHANICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL NECESSARY MECHANICAL
<br />EQUIPMENT AND CONTROLS TO COMPLETE THE JOB. THE MECHANICAL CONTRACTOR IS
<br />TO COORDINATE W/ THE ELECTRICAL CONTRACTOR ALL THE NECESSARY WIRING TO
<br />COMPLETE THE JOB. THE WIRING IS TO BE COMPLETED BY THE ELECTRICAL CONTRACTOR.
<br />3. PROVIDE WHITE SEMI RECESSED SPRINKLER HEADS W/ WHITE TRIM RING @ ALL ACT.
<br />CEILING AND FULLY RECESSED SPRINKLER HEADS W/ WHITE ESCUTCHEON PLATES @ ALL
<br />GYP. CEILING AS REQUIRED BY APPLICABLE CODES AND ORDINANCES.
<br />4. VERIFY LOCATION AND SIZES OF ALL OPENINGS WITH GENERAL CONTRACTOR PRIOR TO
<br />COMMENCING WORK. THE GENERAL CONTRACTOR IS RESPONSIBLE TO CUT & PATCH OR
<br />ADD STRUCTURAL REINFORCING AS REQ'D FOR THE INSTALLATION OF MECHANICAL
<br />ROOFTOP EQUIPMENT.
<br />5. ALL SINKS SHALL HAVE HOT AND COLD WATER WITH BELOW COUNTER PIPE INSULATION
<br />WRAP ON EXPOSED PIPING PER ADA GUIDELINES.
<br />6. PROVIDE AND INSTALL AN APPROPRIATE SIZED WATER HEATER AS REQUIRED.
<br />FINISHES
<br />1. THE CONTRACTOR SHALL PATCH AND REPAIR ANY AND ALL FLOORS, WALLS, CEILINGS, ETC.
<br />IN A WORKMANSHIP-LIKE MANNER TO MATCH THE SURROUNDING SURFACE AREAS.
<br />SURFACES OR MATERIALS DAMAGED BY DEMOLITION OR CONSTRUCTION SHALL BE
<br />REPAIRED, RESTORED AND REFINISHED TO MATCH THE EXISTING, UNLESS NOTED OR
<br />SPECIFIED OTHERWISE. IN ADDITION THOSE EXISTING SURFACES OR MATERIALS (SERVING
<br />AS A SUBSTRATE FOR NEW MATERIALS OR FINISHES) WHICH HAVE BEEN DAMAGED FROM
<br />ANY CAUSE, SHALL BE REPAIRED, RESTORED, PROPERLY PREPARED AND CLEANED TO
<br />RECEIVE THE NEW MATERIALS AND FINISH WORK. ALL NEW MATERIALS & FINISH WORK TO
<br />BE FREE FROM FLAWS & DEFECTS.
<br />2. PATCH AND REPAIR EXISTING FLOOR SLAB AS REQUIRED FOR A SMOOTH AND LEVEL
<br />SURFACE FREE OF DEFECTS. FILL ALL CRACKS AND HOLES AND LEVEL DEPRESSIONS WITH
<br />MATERIALS COMPATIBLE WITH THE FLOOR AND SLAB AS RECOMMENDED BY THE
<br />FLOORING MANUFACTURER.
<br />3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING LEAD TIMES OF ALL
<br />MATERIALS SUCH THAT MATERIALS ARE ON SITE WHEN REQUIRED FOR INSTALLATION.
<br />4. ALL PREPARATION, STORING, INSTALLATION AND CLEANUP OF FINISHES TO CONFORM TO
<br />MANUFACTURER'S SPECIFICATIONS.
<br />5. ALL GRILLES, EXTINGUISHER CABINETS AND MISC. METALS SHALL BE PAINTED TO MATCH
<br />THE SURFACE ON WHICH THEY OCCUR UNLESS NOTED OTHERWISE.
<br />6. ALL HOLLOW METAL DOOR FRAMES TO BE PAINTED TO MATCH THE SURFACE ON WHICH
<br />THEY OCCUR UNLESS NOTED OTHERWISE.
<br />7. CERAMIC, PORCELAIN AND STONE FLOOR TILES TO BE INSTALLED WITH A BRASS OR ZINC 'L'
<br />ANGLE DIVIDER STRIP @ ALL CARPET / FLOOR TILE TRANSITIONS.
<br />8. WHERE VCT MEETS CARPET, A VINYL TRANSITION STRIP SHALL BE INSTALLED, VINYL STRIP
<br />TO MATCH VCT COLOR UNLESS NOTED OTHERWISE.
<br />9. PORCELAIN OR CERAMIC FLOOR TILE TRANSITIONS TO CARPET AT RESTROOM DOOR
<br />ENTRIES SHALL HAVE A SOLID SURFACE MATERIAL (EX. CORIAN THRESHOLD)
<br />ARCHITECTURAL
<br />1. GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, (AIA DOCUMENT A201,
<br />CURRENT EDITION) IN ITS ENTIRETY, ARE PART OF THESE DOCUMENTS. ADDITIONAL NOTES
<br />WITHIN THESE DOCUMENTS ARE NOT MEANT TO OVERRIDE ANY PART OF A201. CONTACT
<br />ARCHITECT FOR A COPY OF A201, IF REQUIRED.
<br />2. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED PROJECT. UNLESS
<br />OTHERWISE INDICATED, THEY DO NOT INDICATE THE MEANS OR METHOD OF CONSTRUCTION.
<br />3. THE CONTRACTOR SHALL OBTAIN SUFFICIENT LIABILITY INSURANCE TO COVER WORKMAN'S
<br />COMPENSATION, GENERAL LIABILITY AND CONTRACTUAL LIABILITY. A COPY SHALL BE FILED
<br />WITH THE OWNER.
<br />4. THE CONTRACTOR SHALL PROVIDE ALL WORK AND MATERIALS AS REQUIRED BY THE
<br />CONSTRUCTION DOCUMENTS AND IN FULL ACCORDANCE WITH ALL APPLICABLE CODES AND
<br />ORDINANCES.
<br />5. THE CONTRACTOR WILL MAINTAIN BUILDER'S RISK INSURANCE ON THE FORM KNOWN AS "ALL
<br />RISK" OR "MULTIPLE PERIL". THE CONTRACTOR, ALL SUBCONTRACTORS, ARCHITECTS AND
<br />ENGINEERS SHALL BE INCLUDED IN EACH CAPACITY AS INSURED JOINTLY WITH THE OWNER IN
<br />ALL POLICIES.
<br />6. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND FIELD CONDITIONS PRIOR TO
<br />ANY DEMOLITION, FABRICATION, CONSTRUCTION OR INSTALLATION & NOTIFY ARCHITECT IF
<br />CONDITIONS, MATERIALS, SIZES AND DIMENSIONS ARE DIFFERENT FROM THOSE SHOWN.
<br />7. CROSS REFERENCE ALL DIMENSIONS AND DETAILS WITH STRUCTURAL, CIVIL, MECHANICAL,
<br />AND ELECTRICAL DRAWINGS BEFORE COMMENCING ANY FABRICATION AND/OR
<br />CONSTRUCTION.
<br />8. CONTRACTORS SHALL INSTALL ALL MANUFACTURED ITEMS, MATERIALS AND EQUIPMENT IN
<br />STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT
<br />WHERE THE SPECIFICATIONS HEREIN, ARE MORE STRINGENT, AND SHALL BE COMPLIED WITH.
<br />9. MATERIALS WHICH ARE SHOWN ON THE DRAWINGS AND WHICH MAY NOT BE SPECIFICALLY
<br />DESCRIBED IN THE SPECIFICATIONS OR DRAWINGS, SHALL BE FURNISHED BY THE
<br />CONTRACTOR AND SHALL BE SUITABLE FOR THE INTENDED USE. MATERIALS SHALL BE IN
<br />HARMONY WITH ADJACENT MATERIALS, AND SHALL BE SUBJECT TO REVIEW FOR
<br />CONFORMANCE WITH THE INTENT OF THE CONTRACT DOCUMENTS. WHERE INSTALLATION
<br />TECHNIQUES ARE NOT SPECIFIED, THEY SHALL BE IN ACCORDANCE WITH MANUFACTURER'S
<br />CURRENT INSTRUCTION AND INDUSTRY STANDARDS.
<br />10. SHOP DRAWINGS PREPARED BY SUPPLIERS, SUBCONTRACTORS, ETC. SHALL BE REVIEWED,
<br />COORDINATED AND SIGNED AND STAMPED BY GENERAL CONTRACTOR PRIOR TO SUBMITTING
<br />TO THE ARCHITECT/ENGINEER.
<br />11. THE CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS, LICENSES AND CERTIFICATES AND
<br />PAY ALL FEES CONNECTED THEREWITH THE ABOVE REFERENCED PROJECT.
<br />12. THE CONTRACTOR SHALL BE RESPONSIBLE TO PREPARE ALL SURFACES FOR PROPER
<br />INSTALLATION OF FINISHES. THIS IS TO INCLUDE, BUT IS NOT LIMITED TO: PATCHING,
<br />SANDING, FLOOR LEVELING, PRIMING, SEALING, SKIM COATING, ETC.
<br />13. THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES FREE FROM WASTE MATERIAL OR
<br />RUBBISH CAUSED BY THE WORK.
<br />14. THE CONTRACTOR SHALL MINIMIZE ANY DAMAGE TO EXISTING CONSTRUCTION AND AREAS
<br />ON THE SITE OUTSIDE OF THE CONSTRUCTION LIMITS. CONTRACTOR TO CONSTRUCT
<br />TEMPORARY WALLS AND BARRIERS AS REQUIRED TO CONTAIN DUST AND DEBRIS AND TO
<br />PROVIDE SAFE PUBLIC ACCESS AND PASSAGE.
<br />15. THE GENERAL CONTRACTOR SHALL LOCATE ALL NEW MECHANICAL UNITS OR RELOCATE ANY
<br />EXISTING UNITS OR ITEMS THAT CONFLICT WITH NEW OR EXISTING FRAMING AND FULL
<br />HEIGHT WALLS. THIS INCLUDES ACCESS FOR ALL CONTROLS, FILTERS, ETC. THIS WORK MUST
<br />BE COORDINATED AND VERIFIED PRIOR TO BIDDING.
<br />16. THE GENERAL CONTRACTOR SHALL COORDINATE AND VERIFY WITH THE RESPECTIVE TRADES
<br />THE SIZES AND LOCATIONS OF MECHANICAL AND/OR ELECTRICAL PENETRATIONS, LOCATIONS
<br />OF FIRE TREATED BACKING/BLOCKING REQUIRED FOR MOUNTING ELECTRICAL AND/OR
<br />MECHANICAL EQUIPMENT, AS WELL AS CUTTING AND PATCHING FOR WORK REQUIRED BY
<br />MECHANICAL/ELECTRICAL.
<br />17. WHEN WORK IS COMPLETED IN AN AREA, THOROUGHLY CLEAN THE SPACES, ITEMS &
<br />SURFACES OF SOIL, WASTE MATERIAL, SMUDGES, SPATTERS, MISAPPLIED MATERIAL, SPOTS,
<br />STAINS, AND THE LIKE, WITHOUT DAMAGING THE MATERIALS AND SURFACES INVOLVED.
<br />18. PROVIDE SEMI RECESSED FIRE EXTINGUISHERS AS REQUIRED BY APPLICABLE CODES AND
<br />ORDINANCES UNLESS NOTED OTHERWISE.
<br />19. ALL DOORS, FRAMES, HARDWARE, LIGHTING AND CEILING MATERIALS ARE TO FOLLOW
<br />BUILDING STANDARDS UNLESS OTHERWISE NOTED.
<br />20. PROVIDE FIRE TREATED BLOCKING IN WALLS AS REQUIRED FOR INSTALLATION OF MILLWORK,
<br />FURNITURE AND ACCESSORIES.
<br />21. THE GENERAL CONTRACTOR IS TO VERIFY BUILDING STANDARDS WITH BUILDING MANAGER.
<br />ALL HARDWARE SETS AND KEYING TO BE COORDINATED WITH BUILDING MANAGERS.
<br />22. ALL INTERIOR GLASS MUST COMPLY W/ APPLICABLE CODES FOR DESIGN LOADS & SAFETY
<br />GLAZING.
<br />23. ALL MATERIALS USED IN PLENUM AREAS MUST BE NON-COMBUSTIBLE AND / OR LISTED FOR
<br />PLENUM USE AS DEFINED BY THE STATE & LOCAL CODES. IT WILL BE THE CONTRACTORS
<br />RESPONSIBILITY TO ADHERE TO THESE REQUIREMENTS.
<br />24. THE GENERAL CONTRACTOR WILL BE RESPONSIBLE TO FIRE CAULK ALL NEW AND EXISTING
<br />PENETRATIONS WITHIN WALL PARTITIONS, ABOVE THE CEILING, AS INDICATED BY THE
<br />APPLICABLE CODES.
<br />SHEET # SHEET DESCRIPTION NOTES
<br />BUILDING USE TYPE SQ. FEET OCC.
<br />FACTOR OCC. LOAD 2 EXITS
<br />REQ'D
<br />OFFICE B 2,315 100 23.15
<br />SHOWROOM M 10,543 30 351.43 -
<br />SERVICE S-1 13,357 100 133.57 -
<br />WAREHOUSE S-1 9,865 300 32.88
<br />TOTAL 541.04 -
<br />CLASSIFICA-
<br />TION OCC.
<br />OCC.
<br />LOAD/
<br />2
<br />WATER CLOSETS LAVATORIES
<br />REQ'D
<br />M
<br />PROV.
<br />M
<br />REQ'D
<br />W
<br />PROV.
<br />W
<br />REQ'D
<br />M
<br />PROV.
<br />M
<br />REQ'D
<br />W
<br />PROV.
<br />W
<br />OFFICE B 13
<br />1/25<50
<br />-
<br />1/25<50
<br />-
<br />1/40<80
<br />-
<br />1/40<80
<br />-.46 .46 --
<br />1/50>50 1/50>50 1/80>80 1/80>80
<br />----
<br />FACTORY &
<br />INDUSTRIAL F 67 1/100 - 1/100 - 1/100 - 1/100 -0.67 0.67 0.67 0.67
<br />MERCANTILE M 176 1/500 - 1/500 - 1/750 - 1/750 -0.35 0.35 0.23 0.23
<br />STORAGE S 17 1/100 - 1/100 - 1/100 - 1/100 -0.17 0.17 0.17 0.17
<br />TOTAL 1.65 2 1.65 2 1.07 2 1.07 2
<br />LANDSCAPE
<br />ARCHITECTURAL
<br />HWY 35E
<br />HWY 36
<br />RICE
<br />PARKING:
<br />STORAGE: 9,865 SF/500 = 19.7
<br />OFFICE: 2,315 SF/200 = 23.2
<br />SHOWROOM: 10,543 SF/200 = 52.7
<br />SHOP: 13,357 SF/500 = 26.7
<br />TOTAL PARKING = 111
<br />PARKING PROVIDED:
<br />84 CUSTOMER, 6 DELIVERY/ DROP-OFF, 26 EMPLOYEE = 116 TOTAL PROVIDED
|