<br />3 of 4 <br /> <br /> <br />10062 Flanders Court NE – Blaine, MN 55449 – Ph: (763) 780-0450 Fax (763) 780-0452 <br /> <br />9. Hydrant valves should be set 1 foot behind the curb and the hydrant set 5 <br />feet behind the curb. <br />Stormwater Management Plan <br />1. Sediment removal must be provided prior to storm water discharge into the <br />infiltration basin. A minimum of a 4 foot sump structure with a S afl Baffle <br />must be added to the lines going into the infiltration basin. <br />2. Drain tile must be extended to the lowest end of the subcut excavation <br />adjacent to Rice Street. <br />3. A note should be added to the detail indicating that 5% iron filings by weight <br />should be added to the fine filter media. It should also be noted that the <br />elevations on Detail 550 do not match the material depths indicated or the <br />elevations utilized in the HydroCAD calculations. <br /> <br />Stormwater Pollution Prevention Plan <br />1. Any mulch used over seeded areas must be hydro mulch. No straw may be <br />used for mulch. <br />2. The applicant should provide more detail on the restoration of the infiltration <br />basin and pond system including a planting plan. Typically standard turf is <br />not maintainable in these areas. <br /> <br />Drainage Calculations <br />1. The time of concentration utilized for the existing and proposed conditions <br />should be based on the actual flow routes and no additional time added as <br />direct entry. The proposed conditions should be revised to note the flow <br />route instead of a direct entry calculation. <br />2. The 10-year discharge rate to Rice Street in the proposed conditions is <br />slightly more than the existing rate. This should be addressed. <br />3. The outlet in the proposed HydroCAD calculations for Pond P1 is noted as an <br />18-inch pipe while the plans note this pipe as 15-inches. The discrepancy <br />should be resolved. <br />4. The outlet in the proposed HydroCAD calculations for Pond P2 has several <br />discrepancies with the plan. The pipe slope of the outlet pipe does not match <br />the plan, the rim elevation of structure MH 200 differs, and three draintile <br />pipes are noted in the plans. This should be revised. <br />5. The required abstraction volume for the site is 4,542 cubic feet. There is a <br />reference to Appendix F in the submittal documents that the Appendix <br />provides the documentation that the storage volume requirements are met. <br />However, Appendix F was not attached. This documentation should be <br />submitted. This documentation should match the stage-storage charts noted <br />in the HydroCAD calculations at the appropriate storage elevation. <br />