My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10-14-2021 Planning Commission Packet
>
Agenda Packets
>
2020-2029
>
2021
>
10-14-2021 Planning Commission Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2022 4:36:42 PM
Creation date
2/10/2022 4:19:33 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROYAL CREDIT UNION <br />200 RIVERFRONT TERRACE <br />EAU CLAIRE, WI 54703 <br />PHONE: 800.341.9911 <br />2640 RICE STREET <br />LITTLE CANADA, MN 55113 <br />NORTH <br />E <br />S <br />W <br />OWNER:• THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING <br />CONDITIONS INCLUDING LOCATIONS OF EXISTING UTILITIES & EASEMENTS. <br />• ALL WORK SHALL BE IN COMPLIANCE WITH LOCAL, STATE & NATIONAL CODES <br />FOR RESPECTIVE TRADES. <br />• DO NOT SCALE DRAWINGS. <br />• THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS. <br />• DRAWINGS & SPECIFICATIONS ARE TO BE CONSIDERED AS SUPPLEMENTING <br />EACH OTHER. WORK SPECIFIED, BUT NOT SHOWN, OR NOT SPECIFIED SHALL <br />BE PERFORMED AS THOUGH MENTIONED IN BOTH SPECIFICATIONS & <br />DRAWINGS. <br />• THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING <br />EXPANSION/CONTROL JOINTS IN ALL MATERIALS, SYSTEMS & BUILDING <br />CONFIGURATIONS INCLUDING CAULKING AS REQUIRED. JOINTS SHALL BE <br />PLACED NO MORE THAN 30 TIMES THE SLAB THICKNESS O.C. BOTH <br />DIRECTIONS IN CONCRETE SLABS, 20' TO 25' O.C. FOR MASONRY WALLS & 20' <br />TO 30' O.C. BOTH DIRECTIONS FOR GYPSUM BOARD WALLS, SOFFITS, <br />CEILINGS, ETC. <br />• THE OWNER AND/OR CLIENT HAS ASSUMED RESPONSIBILITY FOR ALL BIDDING, & <br />RELATED DETAILS. <br />• ALL DETAILS NOT INDICATED SHALL BE THE RESPONSIBILITY OF THE OWNER & <br />CONTRACTOR.I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA.SIGNATURE: TYPED NAME: DATE: LICENSE NUMBER: SET TYPE -DATE: <br />DRAWN BY: <br />JOB NO: <br />PM:9/24/2021 5:33:27 PMBIM 360://21-068 RCU St. Paul/21-068 RCU St.Paul_Cloud_2020.rvtST. PAUL OFFICEROYAL CREDIT UNION2640 RICE STREET, LITTLE CANADA, MN 5511309.24.21 <br />G001 PERMIT 09.24.21BH <br />21-068 <br />BC <br />COVER SHEET 15956CARL G. RUDENBORG09.24.2021RIVER VALLEY ARCHITECTS, INC. <br />3300 BIRCH STREET, SUITE 1A <br />EAU CLAIRE, WI 54703 <br />PHONE: 715.832.0875 <br />ARCHITECT & INTERIOR DESIGN:STRUCTURAL DESIGN: <br />HOEFT BUILDERS, INC. <br />1450 RIVERS EDGE TRAIL <br />ALTOONA, WI 54720 <br />PHONE: 715.833.1761 <br />CONSTRUCTION MANAGER:GENERAL <br />G001 COVER SHEET <br />ERICKSEN ROED & ASSOCIATES <br />3410 OAKWOOD MALL DRIVE #300 <br />EAU CLAIRE, WI 54701 <br />PHONE: 715.552.5336 <br />PHOTO BY: GOOGLE <br />SHEET INDEXPROJECT DIRECTORY <br />LOCATION MAP <br />ROYAL CREDIT UNION <br />ST. PAUL OFFICE <br />2640 RICE STREET <br />LITTLE CANADA, MN 55113 <br />GENERAL NOTES <br />ADVANCED ENGINEERING CONCEPTS <br />1360 INTERNATIONAL DRIVE, SUITE 1 <br />EAU CLAIRE, WI 54701 <br />PHONE: 715.552.0330 <br />CIVIL DESIGN:P.M.E. DESIGN: <br />AUTH CONSULTING & ASSOCIATES -AC/a <br />406 TECHNOLOGY DRIVE, SUITE A <br />MENOMONIE, WI 54751 <br />PHONE: 715.232.8490 <br />A511 CEILING DETAILS <br />A600 DOOR SCHEDULE, HARDWARE GROUPS, DOOR <br />AND WINDOW ELEVATIONS <br />A601 DOOR AND WINDOW DETAILS <br />A602 DOOR AND WINDOW DETAILS <br />A603 DOOR DETAILS <br />A700 ROOM FINISH SCHEDULE & MATERIAL LEGEND <br />A701 FLOOR FINISH PLAN <br />A702 WALL FINISH PLAN <br />ARCHITECTURAL <br />A001 DRAWING CONVENTIONS <br />A002 CODE PLAN <br />A003 WALL TYPES <br />A100 OVERALL PLANS <br />A101 MAIN LEVEL PLAN <br />A102 CANOPY PLANS <br />A103 ROOF PLAN <br />A111 MAIN LEVEL REFLECTED CEILING PLAN <br />A201 EXTERIOR 3D VIEWS <br />A202 EXTERIOR ELEVATIONS <br />A301 BUILDING SECTIONS <br />A311 WALL SECTIONS <br />A312 WALL SECTIONS <br />A401 ENLARGED PLANS <br />A402 ENLARGED PLANS <br />A501 FLOOR EDGE DETAILS <br />A502 ROOF EDGE DETAILS <br />A503 ROOF EDGE DETAILS <br />A504 ROOF DETAILS <br />CIVIL <br />C100 TITLE SHEET <br />C200 EXISTING CONDITIONS & DEMOLITION <br />C300 SITE PLAN <br />C400 UTILITY PLAN <br />C500 GRADING PLAN <br />C600 EROSION CONTROL PLAN <br />C700 DETAILS <br />STRUCTURAL <br />S001 LEAD STRUCTURAL SHEET <br />S002 GENERAL STRUCTURAL NOTES <br />S003 GENERAL STRUCTURAL NOTES CONT <br />S004 TYPICAL DETAILS <br />S005 TYPICAL DETAILS/ SCHEDULES <br />S006 TYPICAL DETAILS/ SCHEDULES <br />S007 TYPICAL WOOD SCHEDULES <br />S008 TYPICAL WOOD SCHEDULES <br />S100 FOUNDATION PLAN <br />S200 FRAMING PLAN <br />S300 FOUNDATION SECTIONS/ DETAILS <br />S301 FRAMING SECTIONS/ DETAILS <br />MECHANICAL <br />M101 MECHANICAL FLOOR PLAN <br />M102 MECHANICAL ROOF PLAN <br />M201 MECHANICAL SCHEDULES AND DETAILS <br />PLUMBING <br />P101 PLUMBING SANITARY/ STORM PLAN <br />P102 PLUMBING WATER PLAN <br />P103 PLUMBING ROOF PLAN <br />P201 PLUMBING RISERS <br />P202 PLUMBING SCHEDULES & DETAILS <br />ELECTRICAL <br />E100 ELECTRICAL SITE PLAN <br />E101 ELECTRICAL LIGHTING PLAN <br />E102 ELECTRICAL POWER PLAN <br />E201 ELECTRICAL SCHEDULES & DETAILS <br />MARKDATEDESCRIPTION
The URL can be used to link to this page
Your browser does not support the video tag.