My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10-14-2021 Planning Commission Packet
>
Agenda Packets
>
2020-2029
>
2021
>
10-14-2021 Planning Commission Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2022 4:36:42 PM
Creation date
2/10/2022 4:19:33 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F.E.C. <br />FIRE EXTINGUISHER <br />F.E. <br />FIRE EXTINGUISHER CABINET <br />F.E.C. <br />CODE PLAN LEGEND <br />MEANS OF EGRESS: <br />EGRESS PATH <br />EXIT LIGHT <br />FIRE EXTINGUISHERS: <br />ACCESSIBLE <br />ENTRY/EXIT <br />ACCESSIBLE <br />ENTRY/EXIT <br />BREAK <br />109 <br />MECH. <br />107 <br />TOILET <br />106 <br />HALL <br />105 <br />IT <br />110 <br />MEMBER SERVICE <br />111 <br />WAITING <br />112 <br />STORAGE <br />113 <br />OFFICE <br />115 <br />OFFICE <br />116 <br />OFFICE <br />117 <br />OFFICE <br />118 <br />EXTERIOR <br />STORAGE <br />108 <br />SD VAULT <br />114 <br />COIN <br />120 <br />VEST. <br />100 <br />CONF. <br />104 <br />OFFICE <br />102 <br />OFFICE <br />103 <br />LOBBY <br />101 <br />SD VIEWING <br />119 <br />ACTUAL BUILDING AREAS <br />FIRST FLOOR INCLUDING CANOPY 3,820 SF <br />TOTAL=3,820 SF <br />OCCUPANCY CALCULATIONS <br />FIRST FLOOR 22 <br />TOTAL OCCUPANT LOAD = 22 <br />E <br />S <br />W <br />NORTH <br />3/16" = 1'-0"A002 <br />1 FIRST FLOOR CODE PLAN <br />EXIT REQUIREMENTS <br />LEVEL <br />OCCUPANCY <br />LOAD <br />EGRESS WIDTH <br />REQUIRED (INCHES) <br />EGRESS WIDTH <br />PROVIDED (INCHES) <br />FIRST FLOOR 22 4.4 72 I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA.SIGNATURE: TYPED NAME: DATE: LICENSE NUMBER: 0'2"4"8"0'4"8"16"0'1'2'4'0'8"16"32"0'16"32"64"0'2'4'8'0'4'8'16'0'8'16'32'SET TYPE -DATE: <br />DRAWN BY: <br />JOB NO: <br />PM:1/16" = 1'-0"1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1 1/2" = 1'-0"3" = 1'-0"3/8" = 1'-0"21 43 65 <br />21 43 65 <br />E <br />A <br />B <br />C <br />D <br />E <br />A <br />B <br />C <br />D <br />9/24/2021 5:35:09 PMBIM 360://21-068 RCU St. Paul/21-068 RCU St.Paul_Cloud_2020.rvtST. PAUL OFFICEROYAL CREDIT UNION2640 RICE STREET, LITTLE CANADA, MN 5511309.24.21 <br />A002 PERMIT 09.24.21BH <br />21-068 <br />BC <br />CODE PLAN 15956CARL G. RUDENBORG09.24.2021PLUMBING FIXTURE COUNTS (PER TABLE 2902.1) <br />FIXTURE REQUIRED PROVIDED <br />WATER CLOSETS 1 1 <br />LAVATORIES 1 1 <br />WATER COOLERS 1 1 <br />SERVICE SINKS 1 1 <br />APPLICABLE CODES <br />BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE (IBC) <br />ACCESSIBILITY CODE: MINNESOTA ACCESSIBILITY CODE 2020 <br />ENERGY CODE: 2015 INTERNATIONAL ENERGY CONSERVATION CODE <br />(IECC) <br />OCCUPANCY CLASSIFICATION IBC CHAPTER 3 <br />B -BUISINESS <br />ALLOWABLE BUILDING HEIGHT & AREA <br />BUILDING HEIGHT:NUMBER OF STORIES: <br />IBC CHAPTER 5 <br />ALLOWABLE BUILDING HEIGHT PER TABLE 504.3 & 504.4: <br />HEIGHT = 40'-0" <br />STORIES = 2 <br />ALLOWABLE BUILDING AREA PER TABLE 506.2 = 9,000 SQ. FT. <br />21'-0"1 <br />TYPE OF CONSTRUCTION IBC CHAPTER 6 <br />TYPE -VB <br />FIRE PROTECTION IBC CHAPTER 9 <br />SPRINKLER REQUIREMENTS: <br />SECTION 903 -AUTOMATIC SPRINKLER SYSTEMS <br />SECTION 906 -PORTABLE FIRE EXTINGUISHERS <br />SEE CODE PLAN <br />NONE <br />IBC 1008.3.2 BUILDINGS. IN THE EVENT OF POWER SUPPLY FAILURE IN BUILDINGS THAT <br />REQUIRE TWO OR MORE MEANS OF EGRESS, AN EMERGENCY ELECTRICAL SYSTEM SHALL <br />AUTOMATICALLY ILLUMINATE ALL THE FOLLOWING AREAS: <br />1. INTERIOR EXIT ACCESS STAIRWAYS & RAMPS. <br />2. INTERIOR & EXTERIOR EXIT STAIRWAYS & RAMPS. <br />3. EXIT PASSAGEWAYS. <br />4. VESTIBULES & AREAS ON THE LEVEL OF DISCHARGE USED FOR EXIT DISCHARGE. <br />5. EXTERIOR LANDINGS FOR EXIT DOORWAYS THAT LEAD DIRECTLY TO THE EXIT DISCHARGE. <br />THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR NOT LESS THAN 90 MINUTES. <br />ILLUMINATION UNDER NORMAL POWER SHALL BE NOT LESS THAN 1 FOOT-CANDLE AT THE <br />WALKING SURFACE. ILLUMINATION UNDER EMERGENCY POWER SHALL BE NOT LESS THAN AN <br />AVERAGE OF 1 FOOT-CANDLE, & A MINIMUM AT ANY POINT OF 0.1 FOOT-CANDLE MEASURED <br />ALONG THE PATH OF EGRESS AT FLOOR LEVEL. <br />PLUMBING SYSTEMS IBC CHAPTER 29 <br />OCCUPANT LOAD IBC CHAPTER 10 <br />MEANS OF EGRESS IBC CHAPTER 10 <br />IBC CHAPTER 10MEANS OF EGRESS ILLUMINATION <br />(ACTUAL OCCUPANT LOAD = 15 PER OWNER LETTER) <br />* <br />* SINK AT BREAKROOM / BOTTLED WATER <br />MARKDATEDESCRIPTION
The URL can be used to link to this page