I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WASPREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM ADULY REGISTERED ENGINEER UNDER THE LAWS OF THE STATE OFMINNESOTA.SIGNATURE:TYPED NAME:Timothy J. AuthDATE:09.24.2021 LICENSE NUMBER: 21087GFI <br />GFI <br />GFI GFI <br />GFIGFIGFI <br />WP/GFI <br />WP/GFIPBPBPBPBT <br />VAULT DOOR <br />POWER 84" <br />46" <br />46" <br />46" <br />FAUCET <br />POWER <br />46" <br />46" <br />46"46" <br />46"46" <br />46"46"46" <br />46" <br />46" <br />46" <br />RTU-1 SERVICE <br />OUTLET <br />120/1 <br />P-A 9 <br />RTU-1 <br />208/1 <br />P-A 50,52,54 <br />RTU-2 SERVICE <br />OUTLET <br />120/1 <br />P-A 11 <br />RTU-2 <br />208/1 <br />P-A 53,55,57 <br />EF-1 <br />120/1 <br />P-A 18 <br />EF-2 <br />120/1 <br />P-A 1 <br />EF-3 <br />120/1 <br />P-A 19 <br />FFH-1 <br />208/1 <br />P-A 14,16 <br />FFH-2 <br />208/1 <br />P-A 21,23 <br />FFH-3 <br />208/1 <br />P-A 24,26 <br />46" <br />46" <br />OFFICE <br />115 <br />OFFICE <br />116 <br />OFFICE <br />117 <br />OFFICE <br />118 <br />VEST. <br />100 <br />OFFICE <br />103 <br />OFFICE <br />102 <br />CONF. <br />104 <br />EXTERIOR STORAGE <br />108 <br />MECH. <br />107 <br />TOILET <br />106 <br />HALL <br />105 <br />BREAK <br />109 <br />IT <br />110 <br />MEMBER SERVICE <br />111 <br />WAITING <br />112 <br />LOBBY <br />101 <br />SD VIEWING <br />119 <br />COIN <br />120 <br />STORAGE <br />113 <br />SD VAULT <br />114 <br />DO-1 <br />120V <br />P-A 3 <br />DO-2 <br />120V <br />P-A 5 <br />FLOOR BOX <br />3/4" CONDUIT FOR <br />POWER AND COMM. <br />2 <br />2 <br />3/4" CONDUIT FOR <br />POWER AND COMM. <br />FLOOR BOX <br />WIRELESS ACCESS POINT <br />WITH (1) CAT6 CABLE/JACK <br />WIRELESS ACCESS POINT <br />WITH (1) CAT6 CABLE/JACK <br />WIRELESS ACCESS POINT <br />WITH (1) CAT6 CABLE/JACK <br />3" CONDUITS FOR PHONE AND COMMUNICATION. <br />COORDINATE EXACT REQUIREMENTS WITH UTILITY <br />PROVIDER. <br />DRIVE THRU SIGNAGE CONTROL <br />FIELD VERIFY EXACT LOCATION. <br />6 <br />3/4" U.G. CONDUIT FOR POWER AND <br />COMM. TO CUSTOMER UNIT, (1) 120V/1, <br />20A CIRCUIT TO EACH UNIT, TYPICAL OF (2). <br />REVERSE ACTING LINE VOLTAGE <br />THERMOSTAT PROVIDED BY M.C. <br />INSTALLED BY E.C. <br />55 <br />3 <br />4 <br />555 <br />5 <br />5 <br />5 <br />5 5 5 <br />5 <br />5 <br />5 <br />5 <br />5 5 <br />5 <br />5WH-1 <br />208/1 <br />P-A 20,22 <br />Irrigation System <br />120/1 <br />P-A 7 <br />1RCP-1 <br />120/1 <br />P-A 27 <br />P-A <br />U.G. CONDUIT TO METER <br />ELECTRIC METER <br />P-A 8 <br />P-A 38P-A 8 P-A 38 <br />P-A 51 P-A 51 P-A 51 <br />P-A 51 <br />P-A 4 P-A 32 <br />P-A 6 <br />P-A 39P-A 39P-A 47 <br />P-A 47 <br />P-A 47 <br />P-A 33 <br />P-A 42 P-A 42 P-A 42 <br />P-A 6 <br />P-A 36 <br />P-A 36 <br />P-A 30 <br />P-A 46 <br />P-A 46 <br />P-A 46 <br />P-A 45 P-A 12 <br />P-A 12 <br />P-A 12P-A 43 <br />P-A 12 <br />P-A 45 <br />P-A 45 <br />P-A 43 <br />P-A 43 <br />P-A 15 <br />P-A 15 <br />P-A 15 <br />P-A 10 <br />P-A 15 P-A 48P-A 48 <br />P-A 10 <br />P-A 48 <br />P-A 48 <br />P-A 49 <br />P-A 49 <br />P-A 10 <br />P-A 41 <br />P-A 44 <br />P-A 49 <br />P-A 44 <br />P-A 44 <br />P-A 41 <br />P-A 35P-A 49 <br />P-A 35 <br />P-A 31 <br />P-A 28 <br />P-A 25 <br />P-A 25 <br />P-A 37 <br />P-A 37 <br />P-A 40 <br />P-A 40 <br />P-A 29 <br />P-A 340'2"4"8"0'4"8"16"0'1'2'4'0'8"16"32"0'16"32"64"0'2'4'8'0'4'8'16'0'8'16'32'SET TYPE -DATE: <br />DRAWN BY: <br />JOB NO: <br />PM:1/16" = 1'-0"1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1 1/2" = 1'-0"3" = 1'-0"3/8" = 1'-0"21 43 65 <br />21 43 65 <br />E <br />A <br />B <br />C <br />D <br />E <br />A <br />B <br />C <br />D <br />9/24/2021 12:26:20 PMBIM 360://21-068 RCU St. Paul/507-099-21 RCU - St.Paul.rvtST. PAUL OFFICEROYAL CREDIT UNION2640 RICE STREET, LITTLE CANADA, MN 5511309.24.21 <br />E102 PERMIT 09.24.21ABC <br />21-068 <br />ELECTRICAL POWER PLAN <br />DWA <br />1/4" = 1'-0"E102 <br />1 ELECTRICAL POWER PLAN <br />Auth Consulting/associates <br />406 TECHNOLOGY <br />DRIVE E. <br />SUITE A <br />MENOMONIE, WI 54751 <br />TEL: 715-232-8490 <br />CORPORATE OFFICE <br />2920 ENLOE <br />STREET <br />SUITE 101 <br />HUDSON, WI 54016 <br />TEL: 715-381-5277 <br />BRANCH OFFICE <br />S&N Land Surveying a division of A c/a <br />. <br />CONSULTANT: <br />authconsulting.com <br />ELECTRICAL KEYED NOTES: <br />1. FIELD VERIFY EXACT POWER REQUIREMENTS AND LOCATION WITH <br />IRRIGATION CONTRACTOR. <br />2. FIELD VERIFY EXACT LOCATION OF RECESSED FLOOR BOX. PROVIDE <br />DECORATIVE COVER . POWER AND DATA. <br />3. PROVIDE 3/4" PLYWOOD ON (3) WALLS. COORDINATE WITH RCU I.T. <br />DEPARTMENT. <br />4. PROVIDE GROUND BAR. COORDINATE WITH RCU I.T. DEPARTMENT. <br />5. PROVIDE ISOLATED GROUND DUPLEX OR QUAD RECEPTACLE. <br />6. FIELD VERIFY LOCATION AND TERMINATION POINT WITH RCU I.T. <br />DEPARTMENT. <br />X <br />ELECTRICAL GENERAL NOTES: <br />• VERIFY FINAL ELECTRICAL AND DATA LOCATIONS WITH OWNER <br />PROVIDED EQUIPMENT/FURNITURE. <br />E <br />S <br />W <br />NORTH <br />MARKDATEDESCRIPTION