Laserfiche WebLink
850855860865870875880885890850855860865870875880885890SAN MH 2 <br />STA 0+13 <br />RE 879.11 <br />IE IN 869.10 <br />IE OUT 861.77 <br />119'-8" PVC @ 6.34%SAN MH 1 <br />STA 0+13 <br />RE 869.63 <br />IE IN 854.20 <br />IE E-W 853.60±6"W.M.EXISTING GROUNDCENTERLINE PROFILEPROPOSED FINISHEDGROUND OVER PIPEIE E-W 853.60± <br />(5-FT DIA. MH REQ'D.)EXIST. 8" DIPWATERMAINEXIST.HYDRANTREAR GARAGE = 893.8GV-0+43 0+00 PC: 0+40.00SS886.5 <br />22-2039FAX: (651) 361-8701PHONE: (651) 361-8210LINO LAKES, MN 550146776 LAKE DRIVESUITE 110SITE PLANNING& ENGINEERINGPLOWEENGINEERING, INC.I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY <br />ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM <br />A DULY LICENSED PROFESSIONAL ENGINEER UNDER <br />THE LAWS OF THE STATE OF MINNESOTA. <br />Date: License No. 43963 <br />ADAM GINKEL <br />01.02.2023 NORTH1 INCH = 30 FEET(22" X 34")HORIZONTALPREPARED FOR: CARA BUILDERSC2.3SHEETVILLAS OF GERVAIS LAKE <br />PLAN/PROFILE - SANITARY SEWER <br />CITY OF LITTLE CANADA, MN 3001530601 <br />2 <br />4 <br />5 <br />6 <br />7 <br />8 <br />3 <br />CWPAGCHECK BY:DRAWN BY:22-2039DATE:JOB NO:07/25/22DESCRIPTIONDATENO.S:\PLOWE\CAD\22PROJ\2039 LITTLE CANADA\2039 CAD\2039 BASE 9.DWGWednesday, December 21, 2022 10:11:16 AMPRELIMINARY <br />RESUBMIT8-5-22 MH 2MH 1CONC COLLAR REQUIRED AROUND ALL ADJUSTING RINGS.ALUMINUM STEPS APPROVED.OR EQUAL, 16" ON CENTER.FULL BED OF MORTAR BETWEEN EACH.ALL JOINTS IN MANHOLE TO HAVEMANHOLE STEPS, NEENAH R1981JCONCRETE ADJUSTMENT RINGS WITHMINIMUM OF 2 AND MAXIMUM OF 5"O" RING RUBBER GASKETS.60"27"7"4'-0"SANITARY MANHOLE 1N.T.S.EXISTING 48" RCP(TO BE CUT TOACCOMMODATE NEW MH)EXISTING 12" PVC (SLIP LINED)CUT EXISTING 12" PVC(APPROX.INV 853.60FLOWNEENAH FRAME AND COVER OR EQUAL, LETTERED"SANITARY SEWER" WITH 2 CONCEALED PICK HOLES.EXISTING 48" RCP(TO BE CUT TOACCOMMODATE NEW MH)EXISTING 12" PVC (SLIP LINED)CONNECTION DETAILSCALE=1:10 (THIS DETAIL ONLY)EXISTING 48" RCPEXISTING 12" PVC (SLIP LINED)REMOVE EXISTING 48" RCP TOACCOMMODATE NEW MANHOLEPLACE 8" CMU BULKHEAD W/ORIFICE FOR EXISTING 12" PVC8" PVCNORTHPLACE 8" CMU BULKHEAD W/ORIFICE FOR EXISTING 12" PVCPLACE 8" CMU BULKHEAD W/ORIFICE FOR EXISTING 12" PVCCONSTRUCTION PLANS9-14-22 <br />RWMWD COMMENTS9-21-22 IF TRAIL IS DAMAGED,RESTORE DISTURBED TRAIL(USE CITY DETAIL STR-9)CITY REVIEW COMMENTS11-30-22 RAMSEY COUNTY PERMIT REQUIRED PRIOR TOANY CONSTRUCTION WITHIN RIGHT-OF-WAY -CONTACT BEN HOFSCHULTE, RAMSEY COUNTYPROJECT PERMIT SUPERVISOR AT 651-266-7198REVISED LOT LAYOUT1-3-23