Laserfiche WebLink
BL 115263748BL 215263748BL 3142536ohohohohohohohoh||ST ST <br />>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>SSS>>>>>>>>>>>>>>>>>>>>>>|||||||||||||||||||||||||||||||||||||||9+50 10+00 8" C900 PVC8" C900 PVC8" C900 PVC <br />SAN MH-4 <br />SAN MH-5 <br />SAN MH-6 8" PVC <br />8" PVC 8" PVC|||||||||>>||||>>||||>>||||>>||||>>||||>>||||>>||||>>||||>>||||>>||||>>|>>>>||>>>>||10+00 11+00 12+00 13+00 14+00 <br />15+0016+0010+0011+0015+2015+00 <br />W-5 HYD-1 <br />W-3 <br />W-4 <br />W-0 <br />W-6 <br />W-7 <br />W-10 <br />W-2 <br />9+5010+00W-13 <br />W-14 <br />HYD-2 <br />CS-1 CS-2 CS-3 CS-4 CS-5 CS-6 CS-7 CS-8 CS-9 CS-10 CS-11 <br />|W-1 8" C900 PVC 53+60 <br />W-12 <br />10" C900 PVC |||||||||||||8" C900 PVC <br />W-11 <br />895 <br />900 <br />905 <br />910 <br />915 <br />920 <br />925 <br />895 <br />900 <br />905 <br />910 <br />915 <br />920 <br />925 <br />907.39907.710+00 906.99907.610+50 907.92907.511+00 908.47907.611+50 908.58907.312+00 908.28906.812+50 907.96906.813+00 908.02906.813+50 908.37907.314+00 908.72906.414+50 15+00907.33907.79+85 907.39907.710+00 14+50 908.79904.215+00 15+25 <br />8" C900 PVC WMN <br />SAN MH-5RIM: 908.05STA 12+80.93, 0.00' RTYPE: 48" DIA.INV: 896.62 (N)INV: 896.52 (S)-207' - 8" PVC SDR-35 SSWR @ 0.40% <br />SAN MH-4 <br />SAN MH-6RIM: 906.80STA 10+25.00, 0.00'TYPE: 48" DIA.INV: 897.64 (S)-256' - 8" PVC SDR-35 SSWR @ 0.40% <br />7.5' MIN. COVER <br />K:\019789-000\Cad\Plan\2ND ADDITION\019789-000-C-UTIL-PLAN-2ND.dwg 2/6/2023 4:57:02 PMSTREET UTILITY <br />PLAN AND <br />PROFILE <br />CU-103 <br />AS SHOWN KWH <br />PTHNDKNSCALE IN FEET <br />0 <br />H: <br />20 40 <br />SCALE IN FEET <br />0 <br />V: <br />5 10 <br />STREET E <br />SCALE: <br />PLAN BY: <br />DESIGN BY: <br />CHECK BY: <br />SHEET <br />WSB PROJECT NO.I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION,OR REPORT WAS PREPARED BY ME OR UNDER MYDIRECT SUPERVISION AND THAT I AM A DULYLICENSED PROFESSIONAL ENGINEER UNDER THELAWS OF THE STATE OF MINNESOTA.LIC. NO:DATE:REVISIONSNO.DATEDESCRIPTIONPIONEER COMMONS - 2ND ADDITIONLENNAR HOMES - LITTLE CANADA, MINNESOTA019789-000 KYLE W. HOFF5970902/06/2023MATCHLINE STA - <br />SEE SHEET - <br />11+00 - STREET 4 <br />CU-101 <br />MATCHLINE STA - 16+00 - STREET 2 <br />SEE SHEET - CU-102STREET 2NOTES <br />1.CONTRACTOR TO INSTALL TRACER WIRE ON ALL PLASTIC WATERMAIN AND SERVICES, IN ACCORDANCE WITH MRWA SPECIFICATIONS. <br />2.CONTRACTOR TO MAINTAIN 18" VERTICAL SEPARATION BETWEEN WATERMAIN/ WATER SERVICES AND SANITARY/ STORM SEWERS AND <br />SANITARY SERVICES. <br />3.WATERMAIN OR WATER SERVICES CROSSING STORM SEWER WITH LESS THAN 3'FEET OF VERTICAL SEPARATION TO INCLUDE MIN. 2" THICK <br />POLYSTYRENE INSULATION. INSULATION TO BE MIN. 4 FEET WIDE AND 5 FEET LONG AND PLACED LONGITUDINALLY IN THE DIRECTION OF <br />THE WATERMAIN OR WATER SERVICE.