Laserfiche WebLink
K:\019789-000\Cad\Plan\2ND ADDITION\019789-000-C-LNSCP-PLAN-2ND.dwg 2/6/2023 4:58:04 PMLS-104 <br />AS SHOWN AM <br />AMKT <br />N <br />SCALE IN FEET <br />0 <br />H: <br />10 20 <br />SCALE: <br />PLAN BY: <br />DESIGN BY: <br />CHECK BY: <br />SHEET <br />WSB PROJECT NO.I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION,OR REPORT WAS PREPARED BY ME OR UNDER MYDIRECT SUPERVISION AND THAT I AM A DULYLICENSED LANDSCAPE ARCHITECT UNDER THELAWS OF THE STATE OF MINNESOTA.LIC. NO:DATE:REVISIONSNO.DATEDESCRIPTIONPIONEER COMMONS - 2ND ADDITIONLENNAR HOMES - LITTLE CANADA, MINNESOTA019789-000 ANDY MASTERPOLE2222602/06/2023LANDSCAPE <br />DETAILS <br />1/2"NOTES: <br />1.ROOTS OF ALL BALLED AND BURLAPPED STOCK SHALL FILL THE SOIL BALL, BE FREE OF KINKS, CIRCLING AND GIRDLING, AND THE <br />UPPERMOST ROOTS SHALL NOT BE MORE THAN FOUR INCHES BELOW THE TOP OF THE SOIL BALL. TRANSPORT ROOTS SHALL BE <br />SYMMETRICAL AROUND THE TRUNK / STEM OF THE PLANTS. SOIL BALLS MUST BE CENTERED OR NO MORE THAN 10% OFF CENTER. <br />2.WHEN MOVING PLANTS, LIFT FROM BENEATH THE ROOT BALL, DO NOT LIFT BY THE TRUNK AND DO NOT BREAK OR LOOSEN THE <br />ROOTBALL. <br />3.BACKFILL PLANTING PIT WITH ORIGINAL SOIL HALFWAY TO THE TOP OF THE ROOTBALL. BREAK UP CLODS OF SOIL. IF SOILS ARE <br />POOR (I.E. HEAVY CLAYS, SAND, OR COMPACTED), BACKFILL CAN BE A MIXTURE OF 1/3 SOIL AMENDMENT MIXED WITH 2/3 ORIGINAL <br />SOIL. DO NO USE PEAT AS PART OF BACKFILL IN CLAY SOILS. REMOVE ALL ROCKS AND DEBRIS FROM BACKFILL AND THEN WATER <br />PLANT AND BACKFILLED AREA TO SETTLE PLANTS AND FILL VOIDS. <br />4.REMOVE ALL WIRE BASKETS FROM THE TOP 1/2 OF THE ROOTBALL AND CONTINUE BACKFILLING REMAINING PLANTING PIT WITH <br />ORIGINAL SOIL. <br />5.WATER THOROUGHLY A SECOND TIME TO SETTLE PLANTS AND FILL VOIDS WITHIN TWO HOURS OF PLANTING. PLACE SPECIFIED <br />MULCH WITHIN 48 HOURS OF THE SECOND WATERING. PROVIDE SUPPORT IF NECESSARY. <br />6.STAKING OF TREES SHALL BE THE CONTRACTORS OPTION. THE CONTRACT IS RESPONSIBLE FOR INSURING THAT ALL PLANTINGS <br />ARE INSTALLED PLUMB AND REMAIN PLUMB THROUGHOUT THE WARRANTY PERIOD OR 1 YEAR AFTER SUBSTANTIAL COMPLETION, <br />WHICHEVER IS GREATER. <br />7.IF STAKING IS INSTALLED ALL COMPONENTS SHALL BE REMOVED BY THE CONTRACTOR AT THE END OF THE WARRANTY PERIOD. <br />REMOVE EXCESS SOIL / ROOTS FROM <br />THE TOP OF SOILBALL TO EXPOSE THE <br />FIRST MAIN LATERAL ROOT. PRUNE ALL <br />ENCIRCLING ROOTS. <br />EACH TREE MUST BE PLANTED WITH THE FIRST <br />MAIN LATERAL ROOT AT FINISH GRADE. TREES <br />WITH THE FIRST MAIN LATERAL ROOT NOT <br />VISIBLE WILL BE REJECTED. <br />REMOVE ALL TWINE AROUND THE STEM.VERTICAL SLITS SHOULD BE CUT IN <br />REMAINING NON-SYNTHETIC <br />BURLAP 16" O.C. <br />ALL SYNTHETIC BURLAP MUST BE <br />REMOVED. TOP 13 OF NON-SYNTHETIC <br />BURLAP MUST BE CUT OFF AND <br />REMOVED COMPLETELY, NOT FOLDED <br />DOWN. <br />TOP 13 OF WIRE BASKET MUST BE <br />CUTOFF AND REMOVED COMPLETELY - <br />DO NOT BEND IT BACK. <br />TREE PLANTING - BALLED & BURLAPPED STOCK1 <br />LS-104 <br />NOTES: <br />1.SEE BALLED AND BURLAPPED PLANTING STOCK DETAIL FOR FURTHER NOTES. <br />TREE MUST MEET OR EXCEED ANSI <br />Z60.1 (AMERICAN STANDARD FOR <br />NURSERY STOCK.) ONE DOMINANT <br />LEADER MUST BE MAINTAINED <br />THROUGH THE WARRANTY PERIOD. <br />4" HIGH EARTH SAUCER BEYOND <br />EDGE OF ROOTBALL, FOR 360°. <br />SET ROOTBALL ON 4"-6" MOUND OF <br />UNDISTURBED / NATIVE SOIL TO <br />PREVENT SETTLING. <br />MULCH RING SHOULD BE MIN. 3" <br />DEEP. KEEP MULCH 4" AWAY FROM <br />TRUNK BASE. <br />EACH TREE MUST BE PLANTED SUCH <br />THAT THE ROOT FLARE IS VISIBLE AT <br />THE TOP OF THE ROOTBALL AND <br />LEVEL WITH FINISH GRADE. <br />DIAMETER OF HOLE SHALL BE TRIPLE THE <br />DIAMETER OF THE ROOTBALL. THE SIDES <br />SHOULD SLOPE GRADUALLY. <br />PRIOR TO MULCHING, LIGHTLY TAMP <br />SOIL AROUND THE ROOTBALL IN 6" <br />LIFTS. DO NOT OVER COMPACT. AFTER <br />BACKFILLING, POUR WATER AROUND <br />ROOTBALL TO SETTLE THE SOIL. <br />RUBBER / NYLON STRAPPING TIGHTENED <br />ONLY ENOUGH TO PREVENT SLIPPAGE. <br />FLAG FOR VISIBILITY. <br />FABRIC GUYING STRAP <br />WITH HOSE CHAFING <br />GUARD <br />AMENDED PLANTING SOIL. SEE <br />SPECIFICATIONS FOR DETAILS <br />METAL STAKES, 2"x24" LONG <br />DRIVEN BELOW FINISH GRADE. <br />DECIDUOUS TREE PLANTING2 <br />LS-104 <br />SET ROOTBALL ON 4"-6" <br />MOUND OF UNDISTURBED / <br />NATIVE SOIL TO PREVENT <br />SETTLING. <br />METAL STAKES, 2"x24" <br />LONG DRIVEN BELOW <br />FINISH GRADE. <br />DIAMETER OF HOLE SHALL BE TRIPLE THE <br />DIAMETER OF THE ROOTBALL. THE SIDES <br />SHOULD SLOPE GRADUALLY. <br />PRIOR TO MULCHING, LIGHTLY TAMP SOIL <br />AROUND THE ROOTBALL IN 6" LIFTS. DO <br />NOT OVER COMPACT. AFTER <br />BACKFILLING, POUR WATER AROUND <br />ROOTBALL TO SETTLE THE SOIL. <br />RUBBER / NYLON STRAPPING TIGHTENED <br />ONLY ENOUGH TO PREVENT SLIPPAGE. <br />FLAG FOR VISIBILITY. <br />FABRIC GUYING STRAP WITH <br />HOSE CHAFING GUARD <br />AMENDED PLANTING SOIL. SEE <br />SPECIFICATIONS FOR DETAILS <br />TREE MUST MEET OR EXCEED ANSI <br />Z60.1 (AMERICAN STANDARD FOR <br />NURSERY STOCK.) ONE DOMINANT <br />LEADER MUST BE MAINTAINED <br />THROUGH THE WARRANTY PERIOD. <br />MULCH RING SHOULD BE MIN. 3" DEEP. <br />KEEP MULCH 4" AWAY FROM TRUNK <br />BASE. <br />EACH TREE MUST BE PLANTED SUCH <br />THAT THE ROOT FLARE IS VISIBLE AT <br />THE TOP OF THE ROOTBALL AND LEVEL <br />WITH FINISH GRADE. <br />4" HIGH EARTH SAUCER BEYOND EDGE <br />OF ROOTBALL, FOR 360°. <br />CONIFEROUS TREE PLANTING6 <br />LS-104 <br />THIN BRANCHES AND <br />FOLIAGE (NOT ALL END TIPS) <br />BY 1/3 RETAINING NORMAL <br />PLANT SHAPE, THINNING, <br />NOT REQUIRED ON <br />EVERGREENS. <br />MOUND PLANTING <br />SOIL 4" TO FORM <br />SAUCER <br />REMOVE BURLAP FROM <br />TOP 1/3 OF BALL REMOVE <br />CONTAINERIZED PLANTS <br />FROM THEIR CONTAINERS <br />MIXTURE <br />PLANTING SOIL <br />EXISTING <br />GRADE <br />3" MULCH <br />6"12"12" <br />NOTES: <br />1.PLANT SHRUBS IN LOCATIONS PER PLAN AND APPROVED BY LA/E. <br />SHRUB PLANTING3 <br />LS-104 <br />PLAN <br />3" DEPTH HARDWOOD <br />MULCH, SEE <br />SPECIFICATIONS <br />PLANTING SOIL MIXTURE <br />PERENNIAL OR <br />GROUND COVER <br />(TYPICAL)4"RECOMMENDED <br />SPACING <br />12"NOTES: <br />1.PLANT PERENNIALS AND GROUNDCOVERS IN LOCATIONS PER PLAN. <br />SECTION <br />PERENNIAL & GROUNDCOVER4 <br />LS-104 <br />METAL EDGE AND MULCH5 <br />LS-104 <br />NOTES: <br />1.SEE BALLED AND BURLAPPED PLANTING STOCK DETAIL FOR FURTHER NOTES. <br />8" STAPLES TO ANCHOR WEED <br />BARRIER AT 3' O.C.; 12" O.C. AT SEAMS <br />AS REQUIRED <br />MULCH, TYPE AND DEPTH AS <br />SPECIFIED <br />WEED BARRIER FABRIC, AS SPECIFIED <br />METAL EDGING, AS SPECIFIED. <br />INSTALL ACCORDING TO <br />MANUFACTURER'S SPECIFICATIONSDEPTHVARIESFINISH GRADE, LAWN