Laserfiche WebLink
|||||||||||||||||||||||LoD LoD LoD LoD LoD LoD LoD LoD LoD LoD LoD LoD LoD LoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDLoDCOUNTY ROAD B100'60'C/EF/OF/OF/OF/OF/OF/OF/OF/OF/OF/OF/OF/OF/OF/OF/OF/OF/OF/ORIM=887.00RIM=894.32RIM=885.08INV=866.9 (PER 2010 ALTA)F/OF/OF/OF/OF/OF/OF/OF/OF/OF/OF/OF/OF/OF/OF/O33'33'C/EC/EC/E20'20'40'C/EC/EC/E20'20'40'EX SAN MH 241-9ARIM=875.00±EX INV=860.00± (N,S)INV=860.10 (E)VERIFY EX PIPE INVERTSSAN MH 03RIM=886.59INV=862.72 (N)INV=862.62 (W)SAN MH 02RIM=887.67INV=864.64 (NW)INV=864.54 (S)91 LF - 8" PVC (SDR 35) @ 2.0%126 LF - 8" PVC (SDR 35) @ 2.0%CBMH 302RIM=886.01INV=875.53SUMP=869.53CB 301RIM=886.01INV=876.7331 LF - 12"RCP @ 5.0%24 LF - 12" RCP @ 5.0%CBMH 402RIM=888.24INV=883.10SUMP=877.10FES 303INV=874.00W/ RIP RAPFES 403INV=874.00W/ RIP RAP44 LF - 12"RCP @ 4.75%24 LF - 12"RCP @ 4.75%CB 401RIM=888.24INV=884.24WET TAP AND CONNECT TO EXISTING12" WATER MAIN WITH 12" x 12" TEEAND 12" x 6" REDUCER. FIELD VERIFYEXISTING PIPE DEPTH AND SIZE.6" CURB STOP & BOXSEE DETAIL X/CXXXHYDRANT6" X 6" TEE6" GATE VALVE6" DIP WM 6" DIP WM 6" GATE VALVE12150' HYDRANTRADIUS, TYP.COPYRIGHT © 2023 BY SOLUTION BLUE INC. ALL RIGHTS RESERVEDSOLUTION BLUE PROJECT NO:REVISION HISTORYDATEDESCRIPTIONI HEREBY CERTIFY THAT THIS PLAN,SPECIFICATION OR REPORT WASPREPARED BY ME OR UNDER MY DIRECTSUPERVISION AND THAT I AM A DULYLICENSED PROFESSIONAL ENGINEERUNDER THE LAWS OF THE STATE OFMINNESOTA.DATE:REG. NO.CERTIFICATION07/28/2023PRELIMINARY SUBMITTAL#01DESIGNED:REVIEWED:PHASE:SUMMARYDRAWN:INITIAL ISSUE:NOT <br /> <br />FORCONS <br />TRUC <br />T <br />ION PRELIMCADD USER: Benjamin Lucas FILE: C:\USERS\BENJAMINLUCAS\DROPBOX\PROJECTS\230303 - LITTLE CANADA AFFORDABLE - LUPE\WORKING FILES\CAD\DWG\PLAN SHEETS\C500 - UTIL.DWG PLOT SCALE: 1:1 PLOT DATE: 7/28/2023 10:18 AM <br />SBINKnow what'sbelow.before you dig.CallR23030307-28-2023BJLC-500UTILITY PLAN - SOUTHBJL||COCOBJLPROPERTY LINELIMITS OF DISTURBANCEBUILDINGCURB & GUTTERSTORM SEWERSANITARY SEWERWATERMAINDRAINTILEGAS LINEOVERHEAD ELECTRICALUNDERGROUND ELECTRICALTELEPHONESWALESOIL BORINGSEMERGENCY OVERFLOWFLARED END SECTIONRIP RAPLIGHT POLEPROPOSEDLEGENDEXISTINGEOFLoD800.00( IN FEET )GRAPHIC SCALEBENJAMIN LUCAS, P.E.XX.XX.202354265LITTLE CANADA, MN <br />LITTLE CANADA DEVELOPMENT1KEYNOTES1. CONTRACTOR SHALL REFER TO CONSTRUCTION NOTESON C-001 PRIOR TO THE START OF CONSTRUCTION.NOTES1. CONNECT TO EXISTING SANITARY MANHOLE VIA CORE DRILL WITH AKOR-N-SEAL (OR APPROVED EQUAL) FLEXIBLE BOOT. EXISTINGSANITARY SEWER PIPE AND STRUCTURES ARE SHOWN PER RECORDPLAN. CONTRACTOR SHALL VERIFY LOCATION AND INVERT OF THEEXISTING PIPES.2. CONNECT TO EXISTING WATERMAIN (SEE DETAIL X/XXXX). EXISTINGWATERMAIN FEATURES ARE SHOWN PER RECORD PLAN.CONTRACTOR SHALL VERIFY LOCATION AND INVERT OF THE EXISTINGPIPES.3. INFILTRATION BASIN BMP: SEE GRADING PLAN FOR ELEVATIONS.CONTRACTOR SHALL OVER EXCAVATE AND REPLACE ANY D SOILSENCOUNTERED WITHIN BASIN AREA WITH WELL DRAINING SOILS.SEE DETAIL X/XXXX.4. UNDERGROUND STORAGE CHAMBER ASSEMBLY. CONTRACTORSHALL OVER EXCAVATE AND REPLACE ANY D SOILS ENCOUNTEREDWITHIN CHAMBER AREA WITH WELL DRAINING SOILS. SEE DETAILSHEET XXXX FOR SPECIFICATIONS AND STORAGE CALCULATIONS.5. ISOLATOR ROW. SEE DETAIL SHEET XXXX.SEE SHEET C-501