Three Phase Inverter for the 120/208V Grid(1) <br />For North America <br />SE17.3KUS <br /> <br />MODEL NUMBER SE17.3KUS UNITS APPLICABLE TO INVERTERS WITH PART NUMBER SEXXK-USX2IXXXX <br />OUTPUT <br />Rated AC Power Output 17300 W <br />Maximum apparent AC output power 17300 VA <br />AC Output Line Connections 3W + PE, 4W + PE <br />AC Output Voltage Minimum-Nominal-Maximum(2) (L-N) 105-120-132.5 Vac <br />AC Output Voltage Minimum-Nominal-Maximum(2) (L-L) 183-208-229 Vac <br />AC Frequency Min-Nom-Max(2) 59.3 - 60 - 60.5 Hz <br />Continuous Output Current (per Phase) 48.25 Aac <br />GFDI Threshold 1 A <br />Utility Monitoring, Islanding Protection, Country Configurable Set <br />Points Yes <br />THD ≤ 3 % <br />Power Factor Range +/- 0.85 to 1 <br />INPUT <br />Maximum DC Power (Module STC) 26000 W <br />Transformer-less, Ungrounded Yes <br />Maximum Input Voltage DC+ to DC- 600 Vdc <br />Operating Voltage Range 370 - 600 Vdc <br />Maximum Input Current 48.25 Adc <br />Maximum Input Short Circuit Current 55 Adc <br />Reverse-Polarity Protection Yes <br />Ground-Fault Isolation Detection 167kΩ Sensitivity(3) <br />CEC Weighted Efficiency 97.5 % <br />Night-time Power Consumption < 4 W <br />ADDITIONAL FEATURES <br />Supported Communication Interfaces 2 x RS485, Ethernet, Cellular (optional) <br />Inverter Commissioning With the SetApp mobile application using built-in Wi-Fi access point for local connection <br />Rapid Shutdown NEC2014, NEC2017 and NEC2020 compliant/certified <br />RS485 Surge Protection Plug-in Supplied with the inverter, Built-in <br />AC, DC Surge Protection Type II, field replaceable, Built-in <br />DC Fuses (Single Pole) 25A, Built-in <br />Smart Energy Management Export Limitation <br />DC SAFETY SWTICH <br />DC Disconnect Integrated <br />STANDARD COMPLIANCE <br />Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 <br />Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) <br />Emissions FCC part15 class A <br />INSTALLATION SPECIFICATIONS <br />AC output conduit size /AWG range ¾” or 1” / 6 - 10 AWG <br />DC input conduit size / AWG range ¾” or 1” / 6 - 12 AWG <br />Number of DC inputs pairs 4 <br />Dimensions with Safety Switch (H x W x D) 31.8 x 12.5 x 11.8 / 808 x 317 x 300 in / mm <br />Weight with Safety Switch 78.2 / 35.5 lb / kg <br />Cooling Fans (user replaceable) <br />Noise < 62 dBA <br />Operating Temperature Range -40 to +140 / -40 to +60(4) ˚F / ˚C <br />Protection Rating NEMA 3R <br />Mounting Bracket provided <br /> <br />(1) For 277/480V inverters refer to: https://www.solaredge.com/sites/default/files/se-three-phase-us-inverter-277-480V-setapp-datasheet.pdf <br />(2) For other regional settings please contact SolarEdge support <br />(3) Where permitted by local regulations <br />(4) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf <br /> <br /> <br /> <br /> <br />© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are <br />trademarks of their respective owners. Date: 1 May, 2022 DS-000069-NAM. Subject to change without notice.