Laserfiche WebLink
7. Limitations of Investigation <br />The Geotechnical Engineer has prepared this report using an ordinary level of care <br />and in accordance with generally accepted foundation and soil engineering practices. <br />Because the borings represent only a small portion of the total site and for other reasons, <br />SPC Engineering & Testing, Inc., does not warrant that the borings are necessarily <br />representative of the entire site but only of the boring locations at the time of <br />investigation. No warranty of the site is made or implied. The boring logs should only be <br />used in preliminary design and estimating work and in conjunction with corrective <br />procedures. <br />The scope of this report is Limited strictly to geotechnical issues which include the <br />establishment of soil profile and only those conclusions expressly made. Please note that <br />this work is not intended to document the presence or absence of any environmental <br />contaminants at the site, nor for identifying applicable local, state or federal laws or <br />regulations of a on- geotechnical nature which may or may not be applicable to this site. <br />Further, SPC Engineering & Testing, Inc., will not be held responsible for facts not <br />disclosed to the Geotechnical Engineer. <br />The bore hole voids were backfrlled by SPC Engineering & Testing, Inc., using <br />native cuttings or sealed as per the Minnesota Department of Health Rules. Some <br />continuing settlement may occur if construction does not take place in the near future. If <br />settlement does occur, the Client should backfill with additional material. <br />This report and all supporting information is furnished only to the Client and his <br />assigns for the designated purpose. No representations to other parties or for other uses <br />are made. <br />Soil samples retrieved during the investigation process will be retained in the office <br />of SPC Engineering & Testing, Inc. for a period of 30 days from the date of testing. After <br />30 days from the date of testing. After 30 days, the samples may be discarded unless a <br />request is received to retain for a longer period. <br />ENGINEER'S CERTIFICATE <br />I hereby certify that this plan, specification or report was prepared by me or under <br />my direct supervision and that I am a duly registered Professional Engineer under the <br />Laws of the State of Minnesota. <br />SPC ENGINEERING & TESTING, INC. <br />Jonathan L. Faraci, PE <br />Minnesota Registration No. 16464 <br />- 1 6 - <br />9 <br />