Page 9 of 20
<br />n_. nerals at least four inches (4 ") high. (Ord. 894, 10 -6 -2003)
<br />(D) Structural Members: All structural members shall be maintained free from deterioration, and shall be
<br />capable of safely supporting the imposed dead and live loads.
<br />(t) Foundation Walls: All foundation walls shall be maintained plumb and free from open cracks and
<br />breaks and shall be kept in such condition so as to prevent the entry of rodents.
<br />(F) Exterior Walls: All exterior walls shall be free from holes, breaks, loose or rotting materials; and
<br />maintained weatherproof and properly surface coated where required to prevent deterioration.
<br />(G) Roofs And Drainage: The roof and flashing shall be sound, tight and not have defects that admit rain.
<br />Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of
<br />the structure. Roof drains, gutters and downspouts shall be maintained in good repair and free from
<br />obstructions. Roof water shall not be discharged in a manner that creates a public nuisance.
<br />(H) Decorative Features: All cornices, belt courses, corbels, terra cotta trim, wall facings and similar
<br />decorative features shall be maintained in good repair with proper anchorage and in a safe condition.
<br />(1) Overhang Extensions: All canopies, marquees, signs, metal awnings, fire escapes, standpipes,
<br />exhaust ducts and similar overhang extensions shall be maintained in good repair and be properly
<br />anchored so as to be kept in a sound condition. When required, all exposed surfaces of metal or wood
<br />shall be protected from the elements and against decay or rust by periodic application of weather -
<br />coating materials, such as paint or similar surface treatment.
<br />(J) Stair And Walking Surfaces: Every stair, ramp, balcony, porch, deck or other walking surface shall
<br />comply with the provisions of subsection 4- 8- 7 -2(1) of this Chapter.
<br />(K) Stairways, Decks, Porches And Balconies: Every exterior stairway, deck, porch and balcony, and all
<br />appurtenances attached thereto, shall be maintained structurally sound, in good repair, with proper
<br />anchorage and capable of supporting the imposed loads.
<br />(L) Chimneys And Towers: All chimneys, cooling towers, smokestacks, and similar appurtenances shall
<br />be maintained structurally safe and sound, and in good repair. All exposed surfaces of metal or wood
<br />shall be protected from the elements and against decay or rust by periodic application of weather -
<br />coating materials, such as paint or similar surface treatment.
<br />1. Legionnaires' Disease: The excess fluids from cooling towers are a known cause of Legionnaires'
<br />disease. The cooling tower fluids shall be monitored and treated so as to prevent any health diseases.
<br />(M)Handrails And Guards: Every handrail and guard shall be firmly fastened and capable of supporting
<br />normally imposed loads and shall be maintained in good condition.
<br />(N) Window, Skylight And Door Frames: Every window, skylight, door and frame shall be kept in sound
<br />condition, good repair and weathertight.
<br />1. Glazing: All glazing materials shall be maintained free from cracks and holes.
<br />2. Openable Windows: Every window, other than a fixed window, shall be easily openable and
<br />capable of being held in position by window hardware.
<br />(0) Insect Screens: During the period from June 1 to September 1, every door, window and other outside
<br />opening required for ventilation of habitable rooms, food preparation areas, food service areas, or any
<br />areas where products to be included or utilized in food for human consumption are processed,
<br />manufactured, packaged or stored, shall be supplied with approved tightly fitting screens of not less
<br />than sixteen (16) mesh per inch and every swinging door shall have a self - closing device in good
<br />working condition.
<br />eption: Screen doors shall not be required where other approved means, such as air curtains or insect
<br />repellant fans, are employed.
<br />(P) Doors: All exterior doors, door assemblies and hardware shall be maintained in good condition. Locks
<br />at all entrances to dwelling units, rooming units and guest rooms shall tightly secure the door.
<br />9
<br />hup://66.113.195.234/MN /Burnsville /doebar.htm 6/9/2006