Laserfiche WebLink
RoomInterior RoomSize(SF) Approximate Dimensions#Total SFFunction Features AdjacenciesNotesCommunity / Gathering Room 4000 50'x80' 14000Rentable gathering space for groups.Recreation program space [impact on storage]150-200 person comfortably [+/- 20 sf per person: code is 15 sf per]Exterior Access -indoor/outdoor features [Operable exterior walls]Secure EntryMain Parking AreaFacility RestroomsKitchenLarge SF per person for programming dictates a higher restroom count possible with a larger actual code based occupant calculationA-3 Occupancy: Occupant Load = 200Two Exits required.Entry/Lobby 600 20'x30' 1600Facility entrance SeatingFireplaceGathering RoomInterior-Access RestroomsStorageOffice 168.75 9'x18'-8" 1168.75Community RoomCirculation SpaceInterior RestroomsKitchen 168.75 9'x18'-8" 1168.75Double basin sinkResidential type Refidgeration equipmentServing countersElectrical for TBD microwaves; TBD number of resident provide warming devices (crock-pots)Gathering RoomCirculation SpaceFamily Restroom 64 8'x8'' 6384Facility RestroomsNon-Gendered(4) Interior Access Only(2) Exterior Access OnlyToilet Room Conforming to MN State Accessibilty Code, Section 1109.2(1) Water Closet(1) Lavatory(1) Baby Changing StationBuilding exteriorGathering RoomEntry/LobbyFinal number TBD based on plumbing fixture requirements per Mn Building CodeAs programmed: [4] WC; [4] LavDiscuss design approach with recreation staff, building official and police representativesGendered Restrooms 187.5 10x18'-8" 2375Facility RestroomsGendered Exterior Access OnlyDoor access at Paved locationIncrease if recreation needs storage spaceB OccupancyGeneral Storage Room 225 12'x18'-8" 1225Facility StorageEntry/LobbyJanitor Closet 56 8'x7' 156Cleaning supply & equipment storage Mop sink, shelving Entry/LobbyBuilding Function Support 225 12'x18'-8" 1225Mechanical Service (HVAC / Water Service)Electrical Service [Coordinate with site lighting demand]Janitorial[Lake aeration compressor currently…if included in this building, acoustic rating][Added electrical for iron filter (now); splash pad future]Entry/Lobby Door large enough for equipment removal and replacement (if required)Exact requirements to be determinedB OccupancyBuilding Circulation and Structural Allowance 5% As Req'd 1310.12525% - 35% possibleB OccupancyBuilding Total6512.625Site AmenityCovered Patio 1140 20'x57' 11140Exterior gathering spacePioneer Park BuildingCity of Little Canada, MNOertel Architects, LtdBuilding Program 197