Laserfiche WebLink
15 <br />APPENDIX E <br />Raw Test Data for Vent /Pickhole Inflow <br />Table values shown are water depths in feet as measured in the receiving tank for each trial. <br />Tests lasted one minute. By averaging the ten test trials in each column and multiplying this re- <br />sult by tank factor 33.5431 GPM per foot of depth, the average GPM for each hole diameter is <br />obtained. <br />Test No. 1 <br />Hole Diameter <br />Trinl 14" 1" 11" 11/2" 9" <br />1 .007 .010 .014 .019 .029 <br />2 .008 .012 .013 .017 .027 <br />3 .007 .011 .013 .019 .026 <br />4 .008 .009 .015 .018 .030 <br />5 .007 .013 .014 .018 .025 <br />6 .008 .011 .014 .018 .027 <br />7 .007 .010 .013 .017 .027 <br />8 .008 .012 .014 .019 .025 <br />9 .008 .011 .015 .017 .020 <br />10 .008 .011 .013 .017 .027 <br />Ave. GPM <br />.365 .462 .600 .912 <br />Test No. 2 <br />1 .023 .032 .044 .066 .098 <br />2 .026 .036 .043 .072 .095 <br />3 .023 .034 .047 .069 .094 <br />4 .026 .035 .045 .071 .097 <br />5 .022 .034 .046 .067 .092 <br />8 .026 .038 .046 .072 .089 <br />7 .025 .032 .043 .066 .091 <br />8 .025 .037 .044 .070 .091 <br />9 .024 .033 .048 .069 .007 <br />10 .026 .033 .048 .071 .094 <br />Ave. GPM <br />.824 1.153 1.522 2224 3.145 <br />Test No. 3 <br />1 .071 .132 .186 .276 .463 <br />2 .074 .133 .180 .277 .469 <br />3 .072 .131 .187 .275 .467 <br />4 .074 .127 .185 .277 .465 <br />5 .071 .127 .186 .272 .468 <br />6 .071 .120 .181 .276 .466 <br />7 .072 .128 .178 .276 .460 <br />8 .074 .132 .182 .277 .462 <br />9 .071 .130 .185 275 .467 <br />10 .073 .133 .187 .275 .467 <br />Ave. GPM 2.424 1.366 6.161 9.243 15.609 <br />-6 <br />