Laserfiche WebLink
FUEL SYSTEMS <br />OLYMPIAN' <br />©non nunxr bouxaiunnu inu�.4 <br />TOP COVER <br />TANK DRAIN <br />EMERGENCY VENT <br />\•04 <br />.# go <br />BREATHER <br />FUEL TANK <br />DIKE <br />DIKE DRAIN <br />FEATURES <br />CONSTRUCTION <br />• Manufactured entirely from <br />8 gauge (4 mm) steel <br />• Continuously welded seams <br />• Formed steel channel type <br />side beams <br />• Unitized load bearing <br />structure <br />• Integral lifting points <br />• Corrosion resistant precoat <br />• Listed to UL142 <br />• Closed top diked base tank <br />AESTHETICS <br />• Continuous high gloss finish <br />• Polyester powder composite <br />• Extremely durable and <br />corrosion resistant <br />LEHX0470-04 (10-03) <br />UL LISTED FUELTANKS <br />FCUL1 -12 HR <br />FCUL2 - 24 HR <br />CLOSED TOP DIKED SKID BASE <br />FUELTANK <br />The generator set skid base contains an <br />integral, UL listed, double walled, steel fuel <br />storage tank with diked rupture basin for the <br />containment of fuel resulting from a tank leak <br />or rupture. The rupture basin is integrally <br />vented and has a closed top to prevent the <br />ingress of precipitation, debris or other <br />elements.The tank is leak tested to 3 psi and <br />pressure tested to 15 psi.The base tank is <br />UL142 listed for Steel Above GroundTanks for <br />Flammable and Combustible Liquids under the <br />"Special PurposeTanks" category. They are <br />intended for installation in accordance with the <br />Flammable and Combustible Liquids Code, <br />NFPA 30 of the National Fire Protection <br />Association. <br />DESIGN FEATURES <br />• Unique integral base and <br />tank design <br />• Developed specifically for <br />open or enclosed generator <br />sets <br />• Containment capacity for <br />fuel <br />• Internal baffles arranged to <br />prevent recirculation <br />of heated return fuel <br />• Brass composite 2" filler cap <br />• Mechanical fuel gauge <br />• Fuel capacities to provide <br />typically 12 and 24 hour <br />standby operation <br />• Primary vent with breather <br />• Vent located accessible for <br />adapting to remote venting <br />• Venting areas to UL142 <br />specifications <br />• Leak detection switch <br />• Emergency vent for <br />main tank <br />• Weatherproof diked <br />containment basin <br />• External NPT drain <br />fittings for fuel tank <br />and containment basin <br />• Removable base -end cover <br />plate encloses stub -up area <br />when used with enclosures <br />11111-1, E" THE W U:RLD> TIIItDI FQR P 0 W'EFt <br />