3 ROUNDABOUT WALL 3 - PLAN & ELEVATION <br />SCALE: 3/16" = 1'-0" <br />HIGH POINT <br />STRUCTURAL SLAB <br />PRECAST CONC. RETAINING WALL <br />PLAN VIEW <br />19'-3" <br />19'-9 <br />"R40'-1 3/16"'R <br />2 <br />1 <br />' <br />- <br />7 <br /> <br />9 <br />/ <br />1 <br />6 <br />" <br />' <br />ELEVATION 4'-6"6' TYP.2'-6"2'-6"10'-3" <br />STRUCTURAL SLAB <br />FINISHED GRADE <br />4 ROUNDABOUT WALL 4 - PLAN & ELEVATION <br />SCALE: 3/16" = 1'-0" <br />53'-7"18'-3"PLAN VIEW <br />ELEVATION <br />HIGH POINT <br />STRUCTURAL SLAB <br />PRECAST CONC. RETAINING WALL <br />R2 <br />1 <br />' <br />- <br />7 <br /> <br />9 <br />/ <br />1 <br />6 <br />" <br />'5'-6"'STRUCTURAL SLAB <br />FINISHED GRADE3'-4 5/8"'3'-10 3/8"'LITTLE CANADA LOGO - SANDBLASTED <br />ON SURFACE OF PRECAST PANELS <br />Welcome to Little Canada <br />6' TYP.R38'-7 1/8"'8'-4" <br />33'-6" <br />HIGH POINT <br />STRUCTURAL SLAB <br />PRECAST CONC. <br />RETAINING WALL <br />PLAN VIEW <br />ELEVATION 4'-6"6' TYP.2'-6"2'-6"2 ROUNDABOUT WALL 2 - PLAN & ELEVATION <br />SCALE: 3/16" = 1'-0" <br />STRUCTURAL SLAB <br />FINISHED GRADE <br />R22'-3 15/16"'36'-3"'18'-3"'1 ROUNDABOUT WALL 1 - PLAN & ELEVATION <br />SCALE: 3/16" = 1'-0" <br />PLAN VIEW <br />ELEVATION 5'-6"'STRUCTURAL SLAB <br />FINISHED GRADE <br />HIGH POINT <br />STRUCTURAL SLAB <br />PRECAST CONC. RETAINING WALL3'-4 5/8"'3'-10 3/8"'LITTLE CANADA LOGO - SANDBLASTED <br />ON SURFACE OF PRECAST PANELS <br />Welcome to Little Canada <br />R28'-6 15/16"'6' TYP. <br />LANDSCAPING PLAN <br />ROUNDABOUT WALL DETAILS <br />PRECAST CONC. RETAINING WALL: <br />1.REFER TO SHEET L2.07 FOR ALL NOTES RELATED TO WALL <br />CONSTRUCTION, PRECAST CONCRETE UNITS AND CIP CONCRETE <br />FOUNDATIONS. <br />2.REFER TO SPEC SECTION 04 7200 FOR PRECAST CONCRETE WALL <br />INFORMATION. <br />METAL EMBLEM SIGNAGE: <br />3.METAL LETTERS TO BE EXTRUDED ALUMINUM. <br />4.METAL SIGN LETTER COLOR TBD. CONTRACTOR TO SUBMIT SAMPLES <br />FOR APPROVAL PRIOR TO FABRICATION & INSTALLATION. <br />5.LETTERS TO BE INSTALLED PER FABRICATORS REQUIREMENTS. <br />SANDBLASTED CITY LOGO: <br />6.CITY LOGO TO BE SANDBLASTED ONTO FACE OF PRECAST CONC. <br />RETAINING WALL UNITS ON MONUMENT SIGNAGE WALLS #1 AND <br />#4. <br />7.CONTRACTOR TO PROVIDE FULL SCALE MOCKUP SHOWING SIZE AND <br />DEPTH OF SANDBLASTED LOGO FOR APPROVAL PRIOR TO <br />CONSTRUCTION. <br />327 <br />SHEET <br /> Bolton & Menk, Inc. 2026, All Rights ReservedcH:\LTCANADA_CI_MN\0N1134421\CAD\C3D\134421-327.dwg 3/5/2026 8:33:40 AMDESIGNED <br />DRAWN <br />CHECKED <br />CLIENT PROJ. NO. <br />ISSUED FOR DATENO. <br />OF <br />CITY OF LITTLE CANADA, MINNESOTA <br />2026 LITTLE CANADA ROAD IMPROVEMENTS <br />0N1.134421 379DATELIC. NO. <br />I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED <br />BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED <br />LANDSCAPE ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA. <br />ERIC HOLT <br />52117 02/06/2026 <br />111 WASHINGTON AVE S, SUITE 650 <br />MINNEAPOLIS, MN 55401 <br />Phone: (612) 416-0220 <br />Email: Minneapolis@bolton-menk.com <br />www.bolton-menk.comR <br /> TH 35E = 062 <br />S.P. 6280-407 <br />S.P. 062-621-012 <br />S.P. 062-621-013 <br />S.P. 200-010-003 <br />S.P. 200-020-013 <br />S.P. 200-101-013 <br />S.A.P.200-101-014