My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
03-25-2026 Council Packet
>
City Council Packets
>
2020-2029
>
2026
>
03-25-2026 Council Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2026 9:03:43 PM
Creation date
4/8/2026 9:00:37 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
236
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONCRETE <br />GRAVEL <br />HATCH PATTERNS <br />GRADING INFORMATION <br />952 <br />950 <br />952 <br />950 <br />1:4 <br />BITUMINOUS <br />F F F F <br />E E E E <br />G G G G <br />XXXXXXSTORM SEWER RECTANGULAR CASTING <br />STORM SEWER CIRCULAR CASTING <br />STORM SEWER FLARED END / APRON <br />CURB BOX <br />FIRE HYDRANT <br />MANHOLE <br />WATER REDUCER <br />WATER BEND <br />PROPOSED TOPOGRAPHIC SYMBOLS <br />CLEANOUT <br />LIFT STATION <br />RIP RAP <br />OE OE OE OE <br />C C C C <br />DRAINAGE FLOW <br />ABBREVIATIONS <br />A ALGEBRAIC DIFFERENCE <br />ADJ ADJUST <br />ALT ALTERNATE <br />B-B BACK TO BACK <br />BIT BITUMINOUS <br />BLDG BUILDING <br />BMP BEST MANAGEMENT PRACTICE <br />BR BEGIN RADIUS <br />BV BUTTERFLY VALVE <br />CB CATCH BASIN <br />C&G CURB AND GUTTER <br />CIP CAST IRON PIPE <br />CIPP CURED-IN-PLACE PIPE <br />CL CENTER LINE <br />CL.CLASS <br />CLVT CULVERT <br />CMP CORRUGATED METAL PIPE <br />C.O.CHANGE ORDER <br />COMM COMMUNICATION <br />CON CONCRETE <br />CSP CORRUGATED STEEL PIPE <br />DIA DIAMETER <br />DIP DUCTILE IRON PIPE <br />DWY DRIVEWAY <br />E EXTERNAL CURVE DISTANCE <br />ELEC ELECTRIC <br />ELEV ELEVATION <br />EOF EMERGENCY OVERFLOW <br />ER END RADIUS <br />ESMT EASEMENT <br />EX EXISTING <br />FES FLARED END SECTION <br />F-F FACE TO FACE <br />FF FINISHED FLOOR <br />F&I FURNISH AND INSTALL <br />FM FORCEMAIN <br />FO FIBER OPTIC <br />F.O.FIELD ORDER <br />GRAN GRANULAR <br />GRAV GRAVEL <br />GU GUTTER <br />GV GATE VALVE <br />HDPE HIGH DENSITY POLYETHYLENE <br />HH HANDHOLE <br />HP HIGH POINT <br />HWL HIGH WATER LEVEL <br />HYD HYDRANT <br />I INVERT <br />K CURVE COEFFICIENT <br />L LENGTH <br />LO LOWEST OPENING <br />LP LOW POINT <br />LT LEFT <br />MAX MAXIMUM <br />MH MANHOLE <br />MIN MINIMUM <br />MR MID RADIUS <br />NIC NOT IN CONTRACT <br />NMC NON-METALLIC CONDUIT <br />NTS NOT TO SCALE <br />NWL NORMAL WATER LEVEL <br />OHW ORDINARY HIGH WATER LEVEL <br />PC POINT OF CURVE <br />PCC POINT OF COMPOUND CURVE <br />PE PERMANENT EASEMENT <br />PED PEDESTRIAN, PEDESTAL <br />PERF PERFORATED PIPE <br />PERM PERMANENT <br />PI POINT OF INTERSECTION <br />PL PROPERTY LINE <br />PRC POINT OF REVERSE CURVE <br />PT POINT OF TANGENT <br />PVC POLYVINYL CHLORIDE PIPE <br />PVMT PAVEMENT <br />R RADIUS <br />R/W RIGHT-OF-WAY <br />RCP REINFORCED CONCRETE PIPE <br />RET RETAINING <br />RSC RIGID STEEL CONDUIT <br />RT RIGHT <br />SAN SANITARY SEWER <br />SCH SCHEDULE <br />SERV SERVICE <br />SHLD SHOULDER <br />STA STATION <br />STD STANDARD <br />STM STORM SEWER <br />TC TOP OF CURB <br />TE TEMPORARY EASEMENT <br />TEMP TEMPORARY <br />TNH TOP NUT HYDRANT <br />TP TOP OF PIPE <br />TYP TYPICAL <br />VCP VITRIFIED CLAY PIPE <br />VERT VERTICAL <br />VPC VERTICAL POINT OF CURVE <br />VPI VERTICAL POINT OF INTERSECTION <br />VPT VERTICAL POINT OF TANGENT <br />WM WATERMAIN <br />AC ACRES <br />CF CUBIC FEET <br />CV COMPACTED VOLUME <br />CY CUBIC YARD <br />EA EACH <br />EV EXCAVATED VOLUME <br />LB POUND <br />LF LINEAR FEET <br />LS LUMP SUM <br />LV LOOSE VOLUME <br />SF SQUARE FEET <br />SV STOCKPILE VOLUME <br />SY SQUARE YARD <br />UNDERGROUND FIBER OPTIC <br />UNDERGROUND ELECTRIC <br />UNDERGROUND GAS <br />UNDERGROUND COMMUNICATION <br />OVERHEAD ELECTRIC <br />OVERHEAD COMMUNICATION <br />OVERHEAD UTILITY <br />953.53 <br />EXISTING CONTOUR MINOR <br />EXISTING CONTOUR MAJOR <br />PROPOSED CONTOUR MINOR <br />PROPOSED CONTOUR MAJOR <br />PROPOSED GRADING LIMITS / SLOPE LIMITS <br />PROJECT LIMITS <br />PROPOSED SPOT ELEVATION <br />RISE:RUN (SLOPE) <br />OC OC OC OC <br />OU OU OU OU <br />STORM SEWER OUTLET STRUCTURE <br />STORM SEWER OVERFLOW STRUCTURE <br />STA:5+67.19 <br />980.87 <br />NOTE: <br />EXISTING UTILITY INFORMATION SHOWN ON THIS PLAN HAS BEEN PROVIDED BY THE UTILITY OWNER. THE CONTRACTOR SHALL FIELD VERIFY <br />EXACT LOCATIONS PRIOR TO COMMENCING CONSTRUCTION AS REQUIRED BY STATE LAW. NOTIFY GOPHER STATE ONE CALL, 1-800-252-1166 OR <br />651-454-0002. <br />THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS UTILITY QUALITY LEVEL D UNLESS OTHERWISE NOTED. THIS UTILITY LEVEL WAS <br />DETERMINED ACCORDING TO THE GUIDELINES OF CI/ASCE 38-22, ENTITLED "STANDARD GUIDELINE FOR INVESTIGATING AND DOCUMENTING <br />EXISTING UTILITIES". <br />UTILITIES IDENTIFIED WITH A QUALITY LEVEL : <br />LINE TYPES FOLLOW THE FORMAT: UTILITY TYPE - QUALITY LEVEL <br />EXAMPLE: UNDERGROUND GAS, QUALITY LEVEL A <br />UTILITY QUALITY LEVEL (A,B,C,D) DEFINITIONS CAN BE FOUND IN CI/ASCE 38-22. <br />UTILITY QUALITY LEVELS: <br />QUALITY LEVEL D: PROVIDES THE MOST BASIC LEVEL OF INFORMATION. IT INVOLVES COLLECTING DATA FROM EXISTING UTILITY RECORDS. <br />RECORDS MAY INCLUDE AS-BUILT DRAWINGS, DISTRIBUTION AND SERVICES MAPS, EXISTING GEOGRAPHIC INFORMATION SYSTEM DATABASES, <br />CONSTRUCTION PLANS, ETC. <br />QUALITY LEVEL C: INVOLVES SURVEYING VISIBLE SUBSURFACE UTILITY STRUCTURES SUCH AS MANHOLES, HAND-HOLES, UTILITY VALVES AND <br />METERS, FIRE HYDRANTS, PEDESTALS AND UTILITY MARKERS, AND THEN CORRELATING THE INFORMATION WITH EXISTING UTILITY RECORDS TO <br />CREATE COMPOSITE DRAWINGS. INCLUDES QUALITY LEVEL D ACTIVITIES. <br />QUALITY LEVEL B: INVOLVES DESIGNATING THE HORIZONTAL POSITION OF SUBSURFACE UTILITIES THROUGH SURFACE DETECTION METHODS AND <br />COLLECTING THE INFORMATION THROUGH A SURVEY METHOD. INCLUDES QUALITY LEVEL C AND D TASKS. <br />QUALITY LEVEL A: PROVIDES THE HIGHEST LEVEL OF ACCURACY. IT INVOLVES LOCATING OR POTHOLING UTILITIES AS WELL AS ACTIVITIES IN <br />QUALITY LEVELS B, C, AND D. THE LOCATED FACILITY INFORMATION IS SURVEYED AND MAPPED AND THE DATA PROVIDES PRECISE PLAN AND <br />PROFILE INFORMATION. <br />G-A G-A <br />EXISTING UTILITY LINES <br />l l l l l l l l l l <br />>>>>> <br />>>>>>>>>>>>>>>>>>>>> <br />>>>>>>>> <br />l l l l l l <br />l l l l l l l l l l l l <br />PROPOSED UTILITY LINES <br />>>>>> <br />>>>>>>>>>>>> <br />BENCHMARK LOCATION <br />MONUMENT FOUND <br />CAST IRON MONUMENT <br />CONTROL POINT <br />SURVEY LINES <br />o o o CONTROLLED ACCESS <br />BOUNDARY <br />CENTERLINE <br />EXISTING EASEMENT LINE <br />PROPOSED EASEMENT LINE <br />EXISTING LOT LINE <br />PROPOSED LOT LINE <br />EXISTING RIGHT-OF-WAY <br />PROPOSED RIGHT-OF-WAY <br />SETBACK LINE <br />SECTION LINE <br />BUSH LINE <br />TREE LINE <br />GUARD RAIL <br />FENCE-DECORATIVE <br />FENCE <br />RETAINING WALL <br />WATER SERVICE <br />WATERMAIN <br />STORM SEWER DRAIN TILE <br />STORM SEWER <br />SANITARY SERVICE <br />SANITARY SEWER <br />FORCEMAIN <br />PIPE CASING <br />WATER SERVICE <br />WATERMAIN <br />STORM SEWER DRAIN TILE <br />STORM SEWER <br />SANITARY SERVICE <br />SANITARY SEWER <br />FORCEMAIN <br />WATER TEE <br />WATER CROSS <br />WATER SLEEVE <br />WATER CAP / PLUG <br />WATER VALVE <br />EXISTING TOPOGRAPHIC LINES <br />QUARTER LINE <br />SIXTEENTH LINE <br />TRAFFIC SIGNS <br />TEMPORARY EASEMENT <br />STONE MONUMENT <br />TRENCHLESS PIPE (PLAN VIEW) <br />TRENCHLESS PIPE (PROFILE VIEW) <br />EXISTING TOPOGRAPHIC SYMBOLS EXISTING PRIVATE UTILITY LINES <br />BENCH <br />BUSH <br />CATCH BASIN CIRCULAR CASTING <br />CURB STOP <br />CATCH BASIN RECTANGULAR CASTING <br />SIGNAL CONTROL CABINET <br />CLEAN OUT <br />DRINKING FOUNTAIN <br />FLARED END / APRON <br />FLAG POLE <br />FUEL PUMP <br />GRILL <br />HANDICAP SPACE <br />HANDHOLE <br />FIRE HYDRANT <br />MAILBOX <br />MANHOLE-HEAT <br />MANHOLE-ELECTRIC <br />MANHOLE-GAS <br />MANHOLE-SANITARY SEWER <br />MANHOLE-STORM SEWER <br />MANHOLE-COMMUNICATION <br />MANHOLE-UTILITY <br />PEDESTRIAN PUSH BUTTON <br />PEDESTAL-ELECTRIC <br />PEDESTAL-COMMUNICATION <br />VALVE POST INDICATOR <br />PARKING METER <br />LIGHT POLE <br />POLE-UTILITY <br />POST <br />PICNIC TABLE <br />RAILROAD SIGNAL POLE <br />REGULATION STATION GAS <br />TREE-DECIDUOUS <br />SATELLITE DISH <br />SIGN TRAFFIC <br />WATER SPIGOT <br />IRRIGATION SPRINKLER HEAD <br />IRRIGATION VALVE BOX <br />TREE STUMP <br />TELEPHONE BOOTH <br />TRANSFORMER-ELECTRIC <br />TREE-DEAD <br />TRASH CAN <br />TRAFFIC SIGNAL <br />VALVE <br />WETLAND <br />WELL <br />TREE-CONIFEROUS <br />GUY WIRE ANCHOR <br />LIFT STATION <br />LIFT STATION CONTROL PANEL <br />MANHOLE-WATER <br />BASKETBALL POST <br />CULVERT END <br />SOIL BORING <br />TRAFFIC ARM BARRIER <br />VENT PIPE <br />TILE INLET <br />TILE RISER <br />SIREN <br />DRIVE-THRU MICROPHONE <br />METER <br />ACCESS GRATE <br />FILL PIPE <br />DOWN SPOUT <br />BIRD FEEDER <br />ANTENNA <br />AIR CONDITION UNIT <br />UTILITY MARKER <br />VALVE VAULT <br />WET WELL <br />YARD HYDRANTY <br />BARRICADE PERMANENT <br />TILE OUTLET <br />SURVEY SYMBOLS <br />PAVEMENT MARKING <br />AUTO SPRINKLER CONNECTION <br />WETLAND DELINEATED MARKER <br />BOLLARD <br />VAULT <br />WW <br />ELECTRIC CAR CHARGE STATIONEV <br />H <br />F <br />CLVT <br />CO <br />B <br />B <br />AC <br />CP <br />L <br />C <br />E <br />G <br />H <br />U <br />S <br />D <br />W <br />MANHOLE-RECLAIMED WATERW <br />M <br />C <br />E <br />P <br />Y <br />WW <br />WS <br />V <br />V <br />U <br />TRASH <br />TILE <br />G <br />RECLAIMED WATER <br />|||||||||||| <br />>>>>>> <br />>>>>>>>>>>>> <br />l l l l l l <br />l l l l l l l l l l l l <br />>>>>>>>>>> <br />>>>>>>>>>>>>>>>>>>>> <br />WR WR WR WR WR <br />G0.02 <br />LEGEND <br />SHEET <br /> Bolton & Menk, Inc. 2026, All Rights ReservedcH:\LTCANADA_CI_MN\26X142412000\CAD\C3D\142412G002.dwg 3/4/2026 2:49:10 PMDESIGNED <br />DRAWN <br />CHECKED <br />CLIENT PROJ. NO. <br />ISSUED FOR DATENO.LITTLE CANADA, MINNESOTA <br />SPOONER PARKING LOT EXPANSION <br />24X.142412.000 <br />BID 02/25/2026 <br />DATELIC. NO. <br />I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED <br />BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED <br />PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. <br />ERIC SEABURG <br />53712 02/25/2026 <br />CRN <br />EJV <br />EJS <br />R <br />3507 HIGH POINT DRIVE NORTH, <br />BLDG. 1 SUITE E130 <br />OAKDALE, MN 55128 <br />Phone: (651) 704-9970 <br />Email: Oakdale@bolton-menk.com <br />www.bolton-menk.com
The URL can be used to link to this page
Your browser does not support the video tag.