My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
05-28-1997 Council Agenda
>
City Council Packets
>
1990-1999
>
1997
>
05-28-1997 Council Agenda
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2014 1:59:28 PM
Creation date
3/7/2013 3:06:05 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
180
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CISCastle Inspection Service <br />A Division of Castle Companies Inc. 2440 Linwood Court <br />Maplewood, MN 55119 <br />Pre -Move Inspection Report <br />Present Location: 6521 21 Avenue, Richfield <br />Proposed Location: 141 Yorkton Ridge, Little Canada <br />1 The installation of hard -wired smoke detectors will be required in each sleeping room, the hallways adjacent to each sleep- <br />ing room, the vaulted area of the living room, and at least one on each floor. <br />2 Any fixtures such as plumbing, electrical and HVAC, that are replaced, must comply with current code requirements. <br />3 If the deck is intended to be moved the boards that are rotted must be replaced and adequate supports provided. <br />4 According to the contractor, new basement walls and garage will be constructed. These will have to meet all the code re- <br />quirements for new structures. <br />5 Electrical service and system must meet current code requirements for the entire building. <br />6 An area of siding is missing on the north side of the structure - this will obviously need to be replaced. <br />7 Exact age of the dwelling is not know, however it appears to be approximately 20 years old and as such the roof covering is <br />deteriorated to the point that it must be replaced. <br />8 There is also an area of the roof structure at the ridge approximately 5 feet in from the north end that is sagging. The con- <br />tractor shall verify that the roof framing is adequate to support the intended loads. <br />9 Submit detailed plans for the new foundation, garage and any other alterations along with a site plan to verify conformance <br />with all City Zoning requirements. <br />Submitted ay 19, 1997 <br />7. <br />Gregory . Schmit, Building Official <br />Phone: 612- 731 -7881 <br />Page 38 <br />
The URL can be used to link to this page
Your browser does not support the video tag.