PLAN REVIEW COMMENTS <br />PROJECT TITLE: Little Canada Daycare <br />BCD PLAN NO: 84159 <br />CH7 OF <br />LITTLE CAN <br />PLAN REVIEWED BY: Wayne Stevens <br />Supervisor, Plan Review <br />The continents listed below refer to documents that make up the Minnesota State <br />Building Code. Certain code deficiencies may not have been included in this <br />report, but that shall not be construed as an approval of such code deficiencies. <br />This review does not relieve the Building Official from checking the documents <br />for compliance with the requirements of the Building Code. <br />1. Reviewing the project for compliance with UBC Section 104(b), <br />the type of construction of the existing building was not indicated <br />on the documents, for this review, it is assumed to be V -N. <br />2. The floor area of the existing E -3 Occupancy is 5,500 sq. ft. <br />This information was provided by the owner Tom Krejci. The architect <br />shall verify if this is correct. <br />3. The B -2, A -3 portion of the building is 5,000 sq. ft. per floor. <br />This was taken from the plot plan, the architect shall verify <br />if this is correct. <br />4. The E Occupancy and B -2 Occupancy shall have a 1 hour occupancy <br />separation. <br />5. This wall is required to be a 2 hour area separation wall for <br />allowable area requirements. See UBC Section 505(e) for area <br />separation wall requirements. <br />6. It is our understanding the two portions of the existing building <br />have not been separated by a property line because of ownership, <br />therefore the building is being reviewed for code requirements <br />as one building. <br />7. The new addition requires two complying exits. The new entryway <br />shall be separated from the existing building corridor by a one <br />hour rated wall and 20 minute doors. It is assumed that the existing <br />building corridor is not a complying exit system. <br />8. The new addition shall be provided with approved <br />dtfir 8alarnd <br />system that complies with NFPA 72 -A -75, see <br />UBC Section 809. <br />9. Submit a copy of energy calculation in compliance with the Minnesota <br />Energy Code. <br />10. The type of insulation over the metal deck was not specified. <br />Foam plastic insulation is required to be protected in accordance <br />with UBC Section 1712. <br />WS :p <br />7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.