My WebLink
|
Help
|
About
|
Sign Out
Home
Search
07/13/2016 P&Z Packet
LinoLakes
>
Advisory Boards & Commissions
>
Planning & Zoning Board
>
Packets
>
2016
>
07/13/2016 P&Z Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2022 3:58:11 PM
Creation date
7/12/2016 12:16:19 PM
Metadata
Fields
Template:
P&Z
P&Z Document Type
P&Z Packet
Meeting Date
07/13/2016
P&Z Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ST. CLAIR ESTATES <br />TITLE SHEET, NOTES & LEGEND <br />LINO LAKES, MN <br />GENERAL NOTES <br />1) THE INFORMATION SHOWN ON THESE DRAWINGS CONCERNING TYPE AND <br />LOCATION OF EXISTING UTILITIES IS NOT GUARANTEED TO BE ACCURATE OR ALL <br />INCLUSIVE. THE CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN <br />DETERMINATION AS TO TYPE AND LOCATION OF UTILITIES AS NECESSARY TO <br />AVOID DAMAGE TO THESE UTILITIES. <br />2) CALL "811" FOR EXISTING UTILITIES LOCATIONS PRIOR TO ANY EXCAVATIONS. <br />3) INSTALLATIONS SHALL CONFORM TO THE CITY STANDARD SPECIFICATIONS <br />AND DETAIL PLATES. <br />4) THE CONTRACTOR SHALL NOTIFY CITY PUBLIC WORKS DEPARTMENT A <br />MINIMUM OF 24 HOURS PRIOR TO THE INTERRUPTION OF ANY SEWER OR WATER <br />SERVICES TO EXISTING HOMES OR BUSINESSES. <br />5) STORAGE OF MATERIALS OR EQUIPMENT SHALL NOT BE ALLOWED ON PUBLIC <br />STREETS OR WITHIN PUBLIC RIGHT-OF-WAY. <br />6) NOTIFY CITY A MINIMUM OF 48 HOURS PRIOR TO THE COMMENCEMENT OF <br />CONSTRUCTION. <br />7) ALL MATERIALS AND INSTALLATIONS SHALL BE IN ACCORDANCE WITH THE <br />CITY'S 2016 GENERAL SPECIFICATIONS AND STANDARD DETAIL PLATES. <br />CURB & BITUMINOUS NOTES <br />1) REMOVAL AND DISPOSAL OF EXISTING STREET MATERIALS AS REQUIRED FOR <br />CONSTRUCTION IS CONSIDERED INCIDENTAL. <br />2) SAW -CUT EXISTING BITUMINOUS AND CONCRETE CURB TO PROVIDE <br />BUTT -JOINT. <br />3) RESTORE DISTURBED STREET TO EXISTING OR BETTER SECTION. <br />4) BACKFILLING OF CURB IS INCIDENTAL TO CURB INSTALLATION. <br />5) THREE (3) INCHES OF CLASS 5 UNDER CURB IS INCIDENTAL TO CURB <br />INSTALLATION. <br />6) CURB ENDS SHALL TERMINATE IN A THREE-FOOT BEAVER TAIL. <br />-,- <br />I <br />I I I <br />I I I <br />I I <br />.;I L----- <br />'D I I I <br />50 6 <br />I I I <br />I � I <br />s I J I — — — — — — — sooroYis•w _ <br />^ { T I a.aei <br />PROPOSED D <br />EASEMENT IN <br />l t:1 <br />SDo'02'rs•w <br />_ 314.73 _ — <br />I v 50 � R <br />I < <br />i <br />' i <br />'C, r\ f PROPOSED TRAIL AND ACCESS ~ �Tn <br />--_ <br />' EASEMENT IN FAVOR OF <br />THE <br />' I o\ CITY OF LINO LAKES <br />.w <br />. yr` - <br />21 <br />---- _ I BY <br />I - <br />i_ _ I <br />`:I _ - <br />I <br />60 I <br />°. <br />I <br />I I - <br />_ _ ..,_ <br />80 I to21 <br />-- <br />wfe� i <br />I � I <br />I I <br />I I I <br />I I <br />I � I <br />I � I <br />I I <br />— — — — — — — — — — — <br />WATER MAIN NOTES <br />1) EXISTING WATER MAIN LOCATION AND SIZE SHALL BE VERIFIED IN THE FIELD <br />PRIOR TO CONSTRUCTION. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO <br />ANY INSTALLATIONS. <br />2) PROVIDE PIPE INSULATION WHERE SEWER (SANITARY OR STORM) CROSSES <br />WITHIN 18" OF WATER MAIN. <br />3) PROPOSED WATER MAIN SHALL BE DIP CLASS 52. PROPOSED WATER <br />SERVICE PIPE SHALL BE 1" COPPER TYPE K. <br />4) TRACER WIRE WILL BE LAID WITH ALL PVC WATER MAINS, VALVE BOXES, <br />AND HYDRANTS (IF APPLICABLE). <br />5) MAINTAIN MINIMUM 7.5-FT COVER TO TOP OF ALL WATER MAIN PIPE. <br />6) PLACE HYDRANTS 4-FT OFF BACK OF CURB. <br />7) WATERMAIN, INCLUDING VALVES, FITTINGS, HYDRANTS AND APPURTENANCES, <br />TO BE WRAPPED IN POLYETHYLENE FILM. <br />8) FITTINGS SHALL BE DUCTILE IRON CLASS 350 COMPACT FUSION -BONDED <br />EPDXY. <br />SANITARY SEWER NOTES <br />1) EXISTING SANITARY SEWER LOCATION, SIZE, AND ELEVATION SHALL BE <br />VERIFIED IN THE FIELD PRIOR TO CONSTRUCTION. NOTIFY ENGINEER OF ANY <br />DISCREPANCIES PRIOR TO ANY INSTALLATIONS. <br />2) PROPOSED SANITARY SEWER MAIN SHALL BE PVC SDR 35 AND SDR 26. <br />3) PROPOSED SANITARY SEWER SERVICES SHALL BE 4" PVC SCHEDULE 40. <br />4) SANITARY SEWER SERVICES SHALL INCLUDE TRACER WIRE. <br />STORM SEWER NOTES <br />1) FIELD VERIFY SIZE, ELEVATION, AND LOCATION OF EXISTING STORM SEWER <br />AND NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO ANY INSTALLATIONS. <br />2) WHEN CALLED OUT AS RCP, STORM SEWER SHALL BE REINFORCED <br />CONCRETE PIPE (RCP) ANSI C76 WITH R-4 GASKETS. <br />3) STORM SEWER LENGTHS INCLUDE THE LAYING LENGTH OF THE FLARED -END <br />SECTION. LAYING LENGTH OF APRON TO BE DEDUCTED FROM PAYMENT LENGTH <br />OF PIPE. <br />4) STORM SEWER PIPES TO BE JOINED TO THE CATCH BASIN MANHOLES W/ <br />APPROVED RESILIENT RUBBER JOINTS TO MAKE THEM GASTIGHT OR <br />WATERTIGHT. CEMENT MORTAR JOINTS ARE PERMITTED ONLY FOR REPAIRS <br />AND CONNECTIONS OF EXISTING LINES CONSTRUCTED WITH SUCH JOINTS. <br />LEGEND <br />OHw <br />EXISTING OVERHEAD ELECTRIC <br />TEL <br />EXISTING UNDERGROUND TELEPHONE <br />CBL <br />EXISTING UNDERGROUND CABLE <br />III <br />EXISTING TELEPHONE PEDESTAL <br />❑F <br />EXISTING FIBER OPTIC PEDESTAL <br />© <br />EXISTING ELECTRICAL PEDESTAL <br />© <br />EXISTING CABLE PEDESTAL <br />C_c� <br />EXISTING UTILITY POLE <br />EXISTING LIGHT POLE <br />» <br />EXISTING STORM SEWER <br />EXISTING WATER MAIN <br />> <br />EXISTING SANITARY SEWER <br />0 <br />EXISTING STORM MANHOLE <br />EXISTING FLARED -END SECTION <br />0g <br />EXISTING GATE VALVE <br />EXISTING HYDRANT <br />S� <br />EXISTING SANITARY SEWER MANHOLE <br />-----930---- <br />... .928............ <br />EXISTING CONTOUR <br />x 920.99 <br />EXISTING SPOT ELEVATION <br />NAVD88 DATUM <br />X <br />EXISTING FENCE <br />wet <br />DELINEATED WETLAND EDGE <br />DELINEATION BY "JACOBSEN <br />ENVIRONMENAL" APRIL 2016 <br />1 <br />PROPOSED <br />WATER PIPE <br />> <br />PROPOSED <br />SANITARY SEWER PIPE <br />>> <br />PROPOSED <br />STORM SEWER PIPE <br />PROPOSED <br />DRAINTILE AND CLEAN -OUT <br />OD <br />PROPOSED <br />STORM MANHOLE <br />❑ <br />PROPOSED <br />CATCH BASIN <br />Q <br />PROPOSED <br />FLARED -END SECTION <br />AT <br />PROPOSED <br />GATE VALVE <br />PROPOSED <br />HYDRANT <br />QS <br />PROPOSED <br />SANITARY SEWER MANHOLE <br />928 <br />PROPOSED <br />CONTOUR <br />930 <br />X24.60 <br />PROPOSED <br />SPOT ELEVATION <br />(GUTTERLINE, BITUMINOUS SURFACE, OR GROUND <br />SURFACE UNLESS OTHERWISE INDICATED) <br />PROPOSED <br />SILT FENCE <br />PROPOSED <br />DIRECTION OF DRAINAGE <br />PROPOSED <br />RIP -RAP <br />PROPOSED <br />INLET PROTECTION <br />0 <br />PROPOSED <br />WETLAND BUFFER SIGNAGE <br />BENCHMARK <br />MNDOT STATION NAME: OTTER MNDT RESET ELEV. = 941.08 FEET (NAVD88) <br />LOCAL BENCHMARK: TOP NUT HYDRANT HYDRANT LOCATED AT THE NW CORNER OF <br />HOKAH DRIVE AND SIOUX LANE. ELEVATION IS 897.49 FEET (NAVD88). <br />— —T— — — — —1— — —� <br />i I <br />I I <br />I I I <br />I I <br />I I I <br />i I <br />I I <br />-- ------ J g L <br />— — — — — — — <br />/ I <br />/ I <br />/ I <br />/ I <br />/ I <br />- p- - - - - - - - - - <br />r <br />T I ~_ Sp - - - - - - - - - <br />J. <br />�c01\ 1 <br />40, <br />o y 0q ga�"0g.dp�y����p�v <br />Rd <br />SHEET INDEX <br />T1 TITLE SHEET, NOTES & LEGEND <br />C1 .1 <br />GRADING, DRAINAGE & EROSION CONTROL PLAN <br />C1 .2 <br />GRADING, DRAINAGE & EROSION CONTROL PLAN <br />C1 .3 <br />WMC BUFFER PLAN <br />C2.1 <br />UTILITY PLAN <br />C2.2 <br />UTILITY PLAN <br />C3.1 <br />DETAILS <br />C3.2 <br />DETAILS <br />C3.3 <br />DETAILS <br />C4.1 <br />STORMWATER POLLUTION PREVENTION PLAN <br />C4.2 <br />STORMWATER POLLUTION PREVENTION PLAN <br />L1 LANDSCAPE PLAN <br />S1 & S2 CERTIFICATE OF SURVEY <br />and RESOURCE INVENTORY <br />S3 OVERALL PRELIMINARY PLAT <br />S4 & S5 PRELIMINARY PLAT <br />S6 & S7 TREE INVENTORY <br />and REMOVAL PLAN <br />Know what's below. <br />Call before you dig. <br />VICINITY MAP <br />2- <br />ru <br />c <br />h SITE <br />Hanvn.own plus CeNUt <br />Linn Lakes Une Stan Bif& Sit <br />I3aruh I <br />DRAWN BY: DESIGN BY: <br />A.G. A.G. <br />CHCKD BY: PROJ. NO. <br />C.W.P. 16-1596 <br />ORIGINAL DATE: <br />MAY 10, 2016 <br />z <br />O <br />a. <br />U <br />W <br />0 <br />z <br />O <br />07 <br />W <br />it <br />V) <br />I- <br />z <br />Ld <br />0 <br />U <br />U <br />LL <br />w0 <br />H z <br />QWwQ <br />ir U J <br />J <br />Q J 2 Q <br />a�Z)~O <br />=LWLIQWpz <br />TL 0 < W LL <br />0 <br />�W=z <br />�- <br />��ozQ <br />WmQW n <br />==k <br />W �Z<W <br />}W z= <br />O <br />LJJ <br />W < <br />01 -Ix <br />Cl <br />TL <br />aWLL <br />0-0 <br />a <br />�a <br />co <br />rn <br />c() <br />O <br />Z <br />J U <br />W J <br />`1 <br />z <br />0 <br />Q <br />0 0 <br />Q <br />It <br />N <br />0 <br />w <br />a <br />(1) <br />o <br />W <br />~ <br />z <br />L� <br />p <br />W <br />W <br />J <br />rrr/^� <br />VJ <br />z <br />'6 <br />W <br />W <br />F__ <br />07 <br />z <br />W <br />Y <br />� <br />W <br />J <br />(� <br />o <br />W <br />n <br />z <br />J <br />W <br />_j <br />rn� <br />V , <br />PREPARED FOR: <br />JAMIE JANSEN <br />SITE PLANNING <br />& ENGINEERING <br />PLOWE <br />ENGINEERING, INC. <br />6776 LAKE DRIVE <br />SUITE 110 <br />LINO LAKES, MN 55014 <br />PHONE: (651) 361-8210 <br />FAX: (651) 361-8701 <br />O <br />i <br />0 50 1100 <br />1 INCH =100 FEET <br />T1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.