Laserfiche WebLink
CADD files prepared by the Consultant for this project are instruments <br />of the Consultant professional services for use solely with respect to <br />this project. These CADD files shall not be used on other projects, for <br />additions to this project, or for completion of this project by others <br />without written approval by the Consultant. With the Consultant's <br />approval, others may be permitted to obtain copies of the CADD <br />drawing files for information and reference only. All intentional or <br />unintentional revisions, additions, or deletions to these CADD files <br />shall be made at the full risk of that party making such revisions, <br />additions or deletions and that party shall hold harmless and indemnify <br />the Consultant from any & all responsibilities, claims, and liabilities. <br />CHECKED BY: <br />DATE: <br />DRAWN BY: <br />PROJECT: <br />REVISIONS: <br />ZHW <br />NMM <br />15328B <br />02/24/17 <br />NUMBER DATE <br />License No. <br />Date <br />I hereby certify that this plan, specification or report was <br />prepared by me or under my direct supervision and that <br />I am a duly Licensed Professional Engineer under the <br />laws of the State of Minnesota. <br />Nicholas M. Mannnel - PE <br />45861 <br />09/12/16 <br />LOUCKS <br />7200 Hemlock Lane, Suite 300 <br />Maple Grove, MN 55369 <br />763.424.5505 <br />www.loucksinc.com <br />PLANNING <br />CIVIL ENGINEERING <br />LAND SURVEYING <br />LANDSCAPE ARCHITECTURE <br />ENVIRONMENTAL <br />RENOVATION AND ADDITIONSLINO LAKES ELEMENTARY SCHOOL - FOREST LAKE AREA SCHOOL725 MAIN STREETLINO LAKES, MN 55014RCWD Submittal 08/19/16 <br />CUP City Submittal 09/12/16 <br />RCWD Resubmittal 09/23/16 <br />Bid Set 12/19/16 <br />Addendum 3 01/23/17 <br />RCWD Resubmittal 02/24/17 <br />RCWD Resubmittal 03/01/17 <br />City Resubmittal 05/15/17 <br />WARNING: <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL <br />EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN <br />MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. <br />THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT <br />LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, <br />CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE <br />DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED <br />DURING CONSTRUCTION AT NO COST TO THE OWNER. <br />SCALE IN FEET <br />0 30 60 <br /> <br />UTILITY NOTES <br />1. ALL SANITARY SEWER, STORM SEWER AND WATERMAIN UTILITIES SHALL BE FURNISHED AND <br />INSTALLED PER THE REQUIREMENTS OF THE SPECIFICATIONS,THE MINNESOTA PLUMBING CODE, THE <br />LOCAL GOVERNING UNIT , AND THE STANDARD UTILITIES SPECIFICATION OF THE CITY ENGINEERS <br />ASSOCIATION OF MINNESOTA (CEAM), 2013 EDITION. <br />2.ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL. ALL <br />COMPACTION SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CEAM SPECIFICATION AND THE <br />GEOTECHNICAL REPORT. <br />3.ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE PERFORMED PER THE REQUIREMENTS OF THE <br />STATE AND LOCAL JURISDICTIONS. THE CITY DEPARTMENT OF ENGINEERING AND BUILDING <br />INSPECTIONS DEPARTMENT AND THE CONSTRUCTION ENGINEER MUST BE NOTIFIED AT LEAST 48 <br />HOURS PRIOR TO ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, OR WORK IMPACTING PUBLIC <br />UTILITIES. <br />4.ALL STORM SEWER , SANITARY SEWER AND WATER SERVICES SHALL TERMINATE 5' FROM THE <br />BUILDING FACE UNLESS OTHERWISE NOTED. <br />5.A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION <br />IS REQUIRED FOR ALL UTILITES UNLESS OTHERWISE NOTED. <br />6.ALL FIRE HYDRANTS SHALL BE LOCATED 5 FEET BEHIND BACK OF CURB OR EDGE OF PAVEMENT <br />UNLESS OTHERWISE NOTED. <br />7.PROPOSED PIPE MATERIALS: <br />WATERMAIN DIP 6" TO 8" DIAMETER <br />STORM SEWER RCP/DUAL WALL HDPE/PVC 8" TO 24" DIAMETER <br />STORM SEWER ARCH RCP 24" ROUND DIAMETER EQUIVALENT <br />8.ALL PORTIONS OF THE STORM SEWER SYSTEM, INCLUDING CATCH BASINS, LOCATED WITHIN 10 <br />FEET OF THE BUILDING OR WATER SERVICE LINE MUST BE TESTED ACCORDANCE WITH MINNESOTA <br />RULES, CHAPTER 4714, SECTION 1109.0 <br />9.ALL JOINTS AND CONNECTIONS IN THE STORM SEWER SYSTEM SHALL BE GASTIGHT OR <br />WATERTIGHT (SEE MINNESOTA RULES, CHAPTER 4714, SECTION 719.6). APPROVED RESILIENT RUBBER <br />JOINTS MUST BE USED TO MAKE WATERTIGHT CONNECTIONS TO MANHOLES, CATCHBASINS, AND <br />OTHER STRUCTURES (SEE MINNESOTA RULES, CHAPTER 4714, SECTION 301.2). <br />10.HIGH-DENSITY POLYETHYLENE (HDPE) STORM DRAINS MUST COMPLY WITH MINNESOTA RULES, <br />PART 4714.0540: <br />a.PIPES 4-INCH TO 10-INCH IN SIZE MUST COMPLY WITH AASHTO M252. <br />b.PIPES 12-INCH TO 60-INCH IN SIZE MUST COMPLY WITH ASTM F2306. <br />c.ALL FITTINGS MUST COMPLY WITH ASTM D3212 (SEE MINNESOTA RULES, CHAPTER 4714, <br />SECTION 301.2). <br />d.WATER-TIGHT JOINTS MUST BE USED AT ALL CONNECTIONS INCLUDING STRUCTURES. <br />e.INSTALLATION MUST COMPLY WITH ASTM D2321. <br />11.PVC STORM WATER PIPE MUST COMPLY WITH ASTM D3034. ASTM F679 PVC EXTERIOR STORM <br />WATER PIPING MAY BE INSTALLED (SEE MINNESOTA RULES, CHAPTER 4714, SECTION 301.2). <br />12.HAND EXCAVATE ENTIRE LENGTH OF FIBER OPTIC LINE TO ENSURE NO DISRUPTION OF SERVICE <br />OR DAMAGE TO CABLE OCCURS. <br />13.DUCTILE IRON PIPE (DIP) WATER SERVICES OR BUILDING SUPPLY LINES MUST MEET AWWA C151 <br />(SEE MINNESOTA RULES, CHAPTER 4714, TABLE 604.1). <br />14.REINFORCED CONCRETE PIPE (RCP) STORM SEWERS COMPLYING WITH ASTM C76 MAY BE <br />INSTALLED (SEE MINNESOTA RULES, CHAPTER 4714, SECTION 301.2). CEMENT MORTAR JOINTS ARE <br />PERMITTED ONLY FOR REPAIRS OR CONNECTIONS TO EXISTING LINES HAVING SUCH JOINTS. <br />CB 10 <br />48" PRECAST <br />STMH 20 <br />CB 30 <br />CBMH 40 <br />STMH 50 <br />STMH 60 <br />R-3067 <br />STMH 80 <br />STMH 90 <br />STMH 70 <br />48" PRECASTR-1642 <br />60" PRECASTR-1642 <br />R-1642 60" PRECAST <br />R-1642 60" PRECAST <br />R-1642 48" PRECAST <br />60" PRECAST <br />48" PRECASTR-3067 <br />R-1642 <br />CB 9 <br />STMH 8 <br />STMH 5 <br />CB 4 <br />CBMH 3 <br />CBMH 6 <br />48" PRECASTR-1642 <br />SEE DETAIL <br />R-3067 <br />48" PRECASTR-1642 <br />48" PRECAST <br />CB 11 24" <br />STORM SEWER SCHEDULE <br />STRUCTURE NO.CASTING MANHOLE SIZE <br />CB 1 24"NYLOPLAST <br />STMH 2 <br />STMH 22 R-2534 <br />STMH 21 48" PRECASTR-1642 <br />STMH 23 48" PRECASTR-1642 <br />SEE DETAIL <br />CB 91 24" <br />CBMH 19 <br />CB 83 <br />CB 82 <br />CB 81 <br />24" <br />24" <br />24"UTILITY PLANC4-1W:\2015\15328A\CADD DATA\CIVIL\_dwg Sheet Files\C4-1 Utility PlanPlotted: 05 /16 / 2017 8:20 AMN <br />STMH 7 R-2534 <br />60" PRECAST <br />NYLOPLAST <br />NYLOPLAST <br />NYLOPLAST <br />NYLOPLAST <br />NYLOPLAST <br />48" PRECASTR-1642 <br />R-3067 <br />24"NYLOPLAST <br />24"NYLOPLAST <br />24"NYLOPLAST <br />STMH 12 48" PRECASTR-1642 <br />48" PRECASTR-3067 <br />STMH 24 48" PRECASTR-1642