Laserfiche WebLink
12 <br />LARGE GENERAL SERVICE (Contd) <br />Determination of Demand The demand in kilovolt -amperes for billing purposes <br />shall be determined by dividing the maximum demand in kilowatts by the <br />monthly average power factor and shall be rounded to the nearest whole kva, <br />but in no month shall the demand to be billed be considered as less than <br />50% of the greatest demand in kva billed during the preceding eleven months <br />nor in any event less than 100 kva. <br />Maximum Demand The maximum demand in kilowatts shall be the greatest 15-minute <br />load during the month for which bill is rendered. <br />Average Power Factor The average power factor is defined to be the quotient <br />obtained by dividing the kilowatt-hours used during the month by the square <br />root of the sum of the squares of the kilowatt-hours used and the lagging <br />reactive kilovolt -ampere -hours supplied during the same period. Any leading <br />kilovolt -ampere -hours supplied during the period will not be considered in <br />determining the average power factor. <br />Minimum Demand to be Billed The monthly minimum billing demand shall not be <br />less than provided above, whether or not energy is used. <br />Standby and Supplementary Service <br />Availability Available at 12,E+00 volts or higher to any large commercial or <br />industrial customer who normally supplies part or all of his electric power <br />requirements from another independent source of power for which the Company's <br />service may be substituted wholly or in part. Customer shall contract for <br />capacity adequate to supply the entire electric requirements for which such <br />service may be used which capacity shall equal or exceed the agreed kva demand <br />for standby to customer's other source of power. Company shall not be obligated <br />to supply capacity in excess of that contracted for. <br />Rate The billing shall be in accordance with Company's Large General Service <br />rate schedule for Service at Primary Distribution Voltage except that the <br />paragraph "Determination of Demand" shall be modified to read as follows: <br />"The demand in kilovolt -amperes for billing purposes shall be determined by <br />dividing the maximum demand in kilowatts by the monthly average power factor, <br />but in no month shall the demand to be billed be considered as less than the <br />agreed standby demand plus 50% of the greatest excess demand in kva over such <br />standby demand billed during the preceding eleven months nor in any event <br />less than 2500 kva." <br />(Continued on following sheet) <br />A <br />