Laserfiche WebLink
6 <br /> <br />Areas around stormwater ponds totaling 16,320 sq. ft. will be seeded with MnDOT 33- <br />261, Stormwater South and West, which is a native mix of grasses, forbs, sedges, and <br />rushes for stormwater pond edges. <br /> <br />Lighting <br /> <br />The purpose of the lighting requirements in the Zoning Code is to reduce light pollution, <br />promote energy conservation, and increase night time safety, utility, security, and <br />productivity. Lighting is reviewed by the City Planner, but some highlights of the <br />lighting requirements follow. <br /> <br />• Maximum height of the fixture and pole must not exceed 30 feet. <br />• The luminaire shall contain a cutoff which directs and cuts off the light at an <br />angle of 90 degrees or less. <br />• Light cast on a public street shall not exceed one foot candle as measured from <br />the right of way. Light cast on adjacent residential property must not exceed 0.4 <br />foot candles as measured from the property line. <br />• Lights serving industrial businesses shall be turned off one hour after closing, <br />except for approved security lighting. <br />• Any illuminated signs for advertising purposes shall be turned off between <br />12:00AM and sunrise except that said signs may be illuminated while the business <br />facility on the premise is open for service. <br /> <br />Recycling <br /> <br />Applicant is planning to construct an enclosure for trash and recycling. This enclosure <br />will be reviewed by the City Planner. <br /> <br />RECOMMENDATIONS <br /> <br />Staff recommends approval of the conditional use permit and site plan review for <br />Laborer’s Training Center Campus Expansion subject to the following comments: <br /> <br />1. Trees in the proposed west pond will have to be surveyed and accounted for in the <br />Tree Preservation and Mitigation Standards. Surface water detention ponds are <br />not considered part of the basic use area, and thus are not exempt from surveys or <br />mitigation standards. Clarification is needed on numbers of trees not in basic use <br />area that are to be removed and thus potentially requiring mitigation. <br /> <br />2. Buffer and screen standards can be met on the eastern perimeter by planting a <br />triangulated double row of coniferous trees that curves west to meet with the <br />northeast edge of the east pond. It is recommended that two or three species <br />suitable for the site conditions are alternated to make this screen more resistant to <br />pests and pathogens than it would be if it were comprised of a single species. <br />