Laserfiche WebLink
0 <br />1 2 3 4 5 <br />A <br />B <br />(::iLAYOUT PLAN -TOWN CENTER COURTYARD <br />11 <br />GAS FIRE UNIT - HPC ROUND BOWL <br />INSERT KIT MODEL PENTA37E1-HI/LO. <br />PROVIDE NATURAL GAS CONNECTION <br />AND EMERGENCY SHUTOFF VALVE. <br />VERIFY AND INSURE UNIT VALVE BOX IS <br />INSTALLED ABOVE GRADE WITH <br />PROPER DRAINAGE. PROVIDE PROPER <br />ELECTRICAL AND FLEXIBLE GAS FEED <br />E PROPERLY RATED FOR UNIT PER <br />MANUFACTURER SPECS. <br />F <br />3" x 6" VENT EA. SIDE W/ SS CUSTOM <br />GRATE TBD BY LA. RECESS GRATE 1/2" <br />INSURE POSITIVE DRAINAGE AT <br />OPENINGS. CONTRACTOR TO VERIFY <br />MINIMUM SIZE PER MANUFACTURER <br />SPECIFICATIONS. <br />fln <br />6'-8" <br />3'-4" <br />im <br />1-3/8" STL ANGLE BRACKET LIP <br />FOR INSERT EA SIDE. <br />3" STONE CAP TO MATCH <br />u ° <br />° <br />0 0 0 a <br />a a ° <br />ntj <br />O 0 <br />CULTURED STONE VENEER TO MATCH <br />ARCHITECTURAL VENEER <br />° PROVIDE BRICK LEDGE FOR CULTURED <br />a <br />STONE VENEER TO MATCH SITE WALLS <br />° <br />a POURED CONC. OR CMU WALLS W/ <br />0 0 FILLED CORE. FOR POURED CONC. <br />WALLS #4 REBAR @ 12" O.C. BOTH <br />WAYS <br />a <br />MIN. 6" COMPACTED SUBGRADE <br />41 a a o �o o��U�U�U�U <br />ADCo 0 0 0 0 0 0 0 0 <br />—IIIIIIIIIIIIIIIIIIIII—III <br />2" MIN. CLEARANCE BETWEEN UNIT AND ° <br />GRADE FOR VENTILATION AND DRAINAGE <br />2" MIN. DRAIN LINE FOR 0 <br />FIRE PIT TO DAYLIGHT <br />FREE DRAINING FILL ° a ° <br />FOOTINGS TO FROST a ° <br />DEPTH AS REQ'D ,�//�ZA <br />a <br />° <br />(:: <br />WALL STONE <br />VERIFY HEIGHT TO INSURE <br />� <br />GAS FIRE INSERT UNIT <br />"' � <br />VALVE BOX IS INSTALLED <br />� w <br />�IoO ABOVE GRADE. DIMS GIVEN <br />"' z <br />� PER PRODUCT DETAIL <br />�� o <br />SHEET. VERIFY W/ <br />� <br />MANUFACTURER. <br />1'-8" <br />1 4 : 16 <br />:, <br />\I <br />""^^T" FINISH STONE CAP TO MATCH <br />TURAL WALL CAPS. CAULK JOINTS. <br />STONE VENEER TO MATCH <br />ARCHITECTURAL VENEER MSV-1 <br />EXPANSION JOINT WHERE WALL ABUTS <br />CONCRETE PLAZA OR OTHER FIXED <br />OBJECTS <br />PROVIDE BRICK LEDGE FOR CULTURED <br />STONE VENEER TO MATCH SITE WALLS <br />POURED CONC. OR CMU BLOCK W/ <br />FILLED CORES. FOR POURED CONC. <br />WALLS #4 REBAR @ 12" O.C. BOTH <br />WAYS <br />POURED CONC. FOOTING #4 REBAR <br />@ 12" O.C. <br />6" MIN. COMPACTED FREE DRAINING <br />GRAVEL AROUND WALL ALL SIDES. <br />6 <br />7 8 <br />L1.0 <br />LAYOUT PLAN NOTES <br />1. <br />REFER TO THE GENERAL NOTES. <br />2. <br />SEE ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR LIGHTING SELECTIONS AND <br />ELECTRICAL INFORMATION. <br />3. <br />SEE CIVIL FOR GRADING INFORMATION. <br />4. <br />SEE SHEET L200 FOR PLANTING NOTES AND DETAILS <br />5. <br />SEE SPECIFICATIONS FOR SOILS AND INSTALLATION REQUIREMENTS. <br />6. <br />SEE CIVIL EXISTING CONDITIONS PLAN FOR BENCHMARKS AND BOUNDARY INFORMATION. <br />7. <br />SEE ARCHITECTURAL DRAWINGS FOR BUILDING INFORMATION. <br />8. <br />DO NOT SCALE THE DRAWINGS. WRITTEN DIMENSIONS ARE TO BE USED FOR ALL LAYOUT <br />WORK. IF A NECESSARY DIMENSION IS NOT SHOWN CONTRACTOR SHALL NOTIFY THE <br />LANDSCAPE ARCHITECT AND REQUEST THE INFORMATION PRIOR TO RELATED WORK. <br />9. <br />AT THE DISCRETION OF THE LANDSCAPE ARCHITECT, ELECTRONIC FILES OR <br />COORDINATES WILL BE PROVIDED TO THE CONTRACTOR FOR SITE LAYOUT/STAKING. <br />10. <br />FIELD VERIFY ALL MEASUREMENTS AND NOTIFY LANDSCAPE ARCHITECT OF ANY <br />DISCREPANCIES WITH SITE CONDITIONS. <br />11. <br />CONTRACTOR SHALL IMMEDIATELY NOTIFY THE LANDSCAPE ARCHITECT OF ANY LAYOUT <br />DISCREPANCIES. <br />Lyngblomsten <br />Senior Communities <br />Hodgson Road, <br />Lino Lakes, MN 55014 <br />Lyngblomsten <br />1415 Almond Ave W, St Paul, MN <br />55108 <br />WOLD ARCHITECTS <br />AND ENGINEERS <br />332 Minnesota Street, Suite W2000 <br />Saint Paul, MN 55101 <br />woldae.com 1 651 227 7773 <br />C 0 L B E R G I T E W S <br />landscape architecture <br />3101 East Franklin Avenue I Minneapolis MN 55406 <br />colbergtews.com <br />NOT FOR <br />CONSTRUCTION <br />CAD FILE, DIGITAL, AND PRINTED <br />DOCUMENT USAGE CONDITIONS <br />CAD files, digital, and printed documents prepared by the <br />Consultant for this project are instruments of the Consultant's <br />professional services for use solely with respect to this project. <br />These files and documents shall not be used on other projects, for <br />additions to this project, or for completion of this project by others <br />without written approval by the Consultant. With the Consultant's <br />approval, others may be permitted to obtain copies of the CAD <br />drawing files for information and reference only. All intentional or <br />unintentional revisions, additions, or deletions to these CAD files, <br />digital, or printed documents shall be made at the full risk of that <br />party making such revisions, additions or deletions and that party <br />shall hold harmless and indemnify the Consultant from any & all <br />responsibilities, claims, and liabilities. <br />I hereby certify that this plan, specification or report was prepared by <br />me or under my direct supervision and that I am a duly Licensed <br />LANDSCAPE ARCHITECT <br />under the laws of the State of Minnesota <br />License Garrett A. Tews <br />Number: 48408 Date 5/11/2020 <br />Revisions <br />Description <br />Date <br />Num <br />PUD Submittal <br />10/08/2018 <br />PUD Resubmittal <br />01/14/2019 <br />PUD Resubmittal <br />03/11/2019 <br />DID SET <br />06/28/2019 <br />CD CHECK SET <br />08/30/2019 <br />CD QAQC CHECK SET <br />09/22/2019 <br />CD SET <br />10/04/2019 <br />PUD DEV STAGE RESUB <br />05/11/2020 <br />Comm: 186024 <br />Date: 05/11 /2020 <br />Drawn: <br />Check: North <br />Town Center <br />Courtyard Layout <br />Plan <br />(::2 GAS FIREPIT WITH ELECTRONIC IGNITION <br />1 -1-0 <br />3 COURTYARD SEAT WALL <br />1 -1-0 <br />Scale: 1/8" - 1'-0" <br />L1.4 <br />