Laserfiche WebLink
• <br />1 Water St West, Suite 110, St Paul, <br />ELECTRO <br />WATCHMAN, INC. <br />FIRE & SECURITY SYSTEMS • SINCE 1921 <br />Minnesota 55107 <br />QUOTE <br />J S K RQ 2424-01 <br />Created: 08/25/20 <br />Expires: 10/10/20 <br />T. 651-227-8461 F. 651-310-1296 <br />Prepared For: <br />City of Lino Lakes <br />600 Town Center Parkway <br />Lino Lakes MN 55014 <br />Justin Williams <br />(651) 982-2452 <br />JWilliams@linolakes.us <br />Prepared By: <br />John Jantzer <br />VP/Account Representative <br />651-310-1257 <br />jjantzer@electrowatchman.com <br />Project Scope: <br />Electro Watchman to provide and install upgrades to City of Lino Lakes access control system as part of a touchless <br />entry door upgrade provided by others. Work includes upgrades to existing door locations to integrate newly <br />installed automatic door operator systems for touchless doors as well as installation of new access control door <br />locations with touchless/auto operators. <br />For new access control door locations, Electro Watchman will provide cabling to door, card readers with installation, <br />and auto door operator relay to control auto operator. Electra Watchman will provide sufficient low voltage power <br />supplies for standard electric locking hardware and auto operator relay units. <br />Door installer to provide all electric locking hardware, including installation for the project. Door installer will pull <br />access control cables through door frames on replacement door installations and will cut in electric locking <br />hardware on existing doors. Door installer will provide and install auto operator and touchless buttons on all door <br />locations. <br />Reuse existing card readers and electric locking hardware on existing doors. Additional cabling and logic relay <br />must be added at each auto operator to control door function properly. <br />Facilities without existing access control systems will have a new network controller node unit installed for all door <br />connections. Facilities with existing access control will expand existing controllers to meet new reader capacity. <br />8/25/20 DOCUMENT REVISION - Removed childcare wing doors on tenant access control system. Added L104 <br />door to election storage room. <br />Qty Description <br />Unit Price Ext. Price <br />1 City Hall & Police Department - S2 Systems Access Control <br />Expansion to Integrate Auto Door Operators and Expand Access <br />Control Locations Throughout the Facility: <br />• (5) ACCESS CONTROL APPLICATION EXTENSION BLADE WITH <br />SUPPORT FOR 2 OSDP OR 2 WIEGAND READERS, 4 INPUTS AND 4 <br />OUTPUTS. <br />• (3) POWER SUPPLY - 12/24VDC 6A, 6 OUT <br />• (6) BATTERY, 12V, 7AH„5.94"L X 2.56"W X 3.70"H <br />• (21) ADVANCED LOGIC RELAY <br />• (8) RECESSED DOOR CONTACTS <br />• (9) CARD READER - MULTICLASS, SINGLE GANG, BLACK, PIGTAIL <br />• (2) READER, RP15, MULTICLASS, MULLION, 32 BIT, BLACK <br />• (5100) CABLE - 22/6 OAS CMP <br />• (1800) CABLE - 18/2 CMP <br />$27,589.75 <br />Created on 08/25/20 16:10:11 by jjantzer <br />Page 1 of 4 <br />