Laserfiche WebLink
3 x3 / 5 x HEIGHT18"B <br />AB B AMINIMUM TREE SPADE SIZE REQUIREMENTSOAK TREE,CALIPERDECIDUOUS/ORNAMENTALTREE,CALIPERCONIFEROUSTREE, HEIGHT42"1" to 1.5"2" to 3"5' to 7'60"1.5" to 2.5"3" to 4"7' to 9'78"2.5" to 3.5"4" to 6"9' to 14'85"3.5" to 5"6" to 8"14' to 18'(C) SPADEDIAMETERSIZEBALLED & BURLAPPED STOCK1.SCARIFY SIDES AND BOTTOM OF HOLE.2.PROCEED WITH CORRECTIVE PRUNING.3.SET PLANT ON UNDISTURBED NATIVE SOIL OR THOROUGHLYCOMPACTED PLANTING SOIL. INSTALL PLANT SO THE ROOTFLARE IS AT OR UP TO 2" ABOVE THE FINISHED GRADEWITH BURLAP AND WIRE BASKET, (IF USED), INTACT.4.SLIT REMAINING TREATED BURLAP AT 6" INTERVALS.5.BACKFILL TO WITHIN APPROXIMATELY 12" OF THE TOP OFTHE ROOTBALL, THEN WATER PLANT.6.REMOVE THE TOP 1/3 OF THE BASKET OR THE TOP TWOHORIZONTAL RINGS WHICHEVER IS GREATER. REMOVE ALLBURLAP AND NAILS FROM THE TOP 1/3 OF THE BALL.REMOVE ALL TWINE. REMOVE OR CORRECT STEM GIRDLINGROOTS.7.PLUMB AND BACKFILL WITH PLANTING SOIL.8.WATER THOROUGHLY WITHIN 2 HOURS TO SETTLE PLANTSAND FILL VOIDS.9.BACK FILL VOIDS AND WATER A SECOND TIME.10.PLACE MULCH WITHIN 48 HOURS OF THE SECOND WATERINGUNLESS SOIL MOISTURE IS EXCESSIVE.1.SOAK ROOTS IN WATER FOR AT LEAST ONE HOUR BUTNOT MORE THAN 24 HOURS PRIOR TO PLANTING.2.SCARIFY SIDES AND BOTTOM OF HOLE.3.PROCEED WITH CORRECTIVE PRUNING OF THE TOP ANDROOTS.4.TRANSFER PLANT DIRECTLY FROM WATER TO HOLE. SETPLANT SO THE ROOT FLARE IS AT THE FINISHED SOILELEVATION. SPREAD ROOTS OUT EVENLY. PLUMB ANDIMMEDIATELY BACKFILL WITH PLANTING SOIL.5.WATER THOROUGHLY WITHIN 2 HOURS TO SETTLEPLANTS AND FILL VOIDS.6.BACK FILL VOIDS AND WATER A SECOND TIME.7.PLACE MULCH WITHIN 48 HOURS OF THE SECONDWATERING UNLESS SOIL MOISTURE IS EXCESSIVE.BARE ROOT STOCK1.SCARIFY SIDES AND BOTTOM OF HOLE.2.PROCEED WITH CORRECTIVE PRUNING OF TOP AND ROOT.3.REMOVE CONTAINER AND SCORE OUTSIDE OF SOIL MASSTO REDIRECT AND PREVENT CIRCLING FIBROUS ROOTS.REMOVE OR CORRECT STEM GIRDLING ROOTS.4.SET PLANT ON UNDISTURBED NATIVE SOIL ORTHOROUGHLY COMPACTED PLANTING SOIL. INSTALLPLANT SO THE TOP OF THE ROOT FLARE IS AT OR UPTO 2" ABOVE THE FINISHED GRADE.5.PLUMB AND BACKFILL WITH PLANTING SOIL.6.WATER THOROUGHLY WITHIN 2 HOURS TO SETTLE PLANTAND FILL VOIDS.7.BACK FILL VOIDS AND WATER A SECOND TIME.8.PLACE MULCH WITHIN 48 HOURS OF THE SECONDWATERING UNLESS SOIL MOISTURE IS EXCESSIVE.CONTAINER STOCKMACHINE MOVED STOCK1.SCARIFY SIDES AND BOTTOM OF HOLE.2.PROCEED WITH CORRECTIVE PRUNING.3.SET PLANT ON NATIVE SOIL AT SAME DEPTH AS IT WASPREVIOUSLY GROWN.4.PLUMB AND BACKFILL WITH PLANTING SOIL.5.AFTER PLANTING, LOOSEN THE SOIL IMMEDIATELYADJACENT TO THE ROOT BALL TO A MINIMUM DISTANCEOF 18" AND A MINIMUM DEPTH OF 12".6.WATER THOROUGHLY WITHIN 2 HOURS TO SETTLE PLANTAND FILL VOIDS.7.BACK FILL VOIDS AND WATER A SECOND TIME.8.PLACE MULCH WITHIN 48 HOURS OF THE SECONDWATERING UNLESS SOIL MOISTURE IS EXCESSIVE.FOR PLANTING SOILDETAIL SEE STANDARDPLANTING DETAILS (A)FOR PLANTING SOILDETAIL SEE STANDARDPLANTING DETAILS (A)FOR PLANTING SOILDETAIL SEE STANDARDPLANTING DETAILS (A)LOOSENEDSOILFOR PLANTING SOILDETAIL SEE STANDARDPLANTING DETAILS (A)FOR MULCH DETAILSEE STANDARDPLANTING DETAIL (B)FOR MULCH DETAILSEE STANDARDPLANTING DETAIL (B)(MnDOT 2571.3F)PLANTING HOLE DIMENSIONSHOLE DEPTH FOR B&B AND CONTAINER PLANTS SHALL NOT EXCEED MEASUREMENT FROM ROOTFLAIR TO BOTTOM OF SOIL BALL.PLANT TYPEPLANT SIZE UP TOAND INCLUDING(A) MINIMUM HOLEWIDTH(B) APPROXIMATEHOLE DEPTHDECIDUOUS &ORNAMENTALTREES3' B.R.46"13"4' B.R46"14"5' B.R.48"14"6' B.R.54"15"7' B.R60"16"8' B.R.66"19"0.75" B.R.48'12"1" B.R.54"14"1.25" B.R.60"14"1.5 B.R.66"15"1.75" B.R72"16"2" B.R.84"19"4' B.B.42"11"5' B.B.48"12"6' B.B.52"14"8' B.B.66"16"10' B.B.66"16"12' B.B.48"16"1" B.B.54"14"1.25" B.B.56"15"1.5" B.B.61"15"1.75" B.B.66"16"2" B.B.72"16"2.5" B.B.84"19"3" B.B.96"20"3.5" B.B.114"23"4" B.B.126"25"DECIDUOUSSHRUBS, ROSESAND PERENNIALS12" B.R.24"7"15" B.R.28"8"18" B.R.30"8"2' B.R.33"9"3' B.R.42"11"4' B.B.48"12"PERENNIAL HOLEDEPTH AND WIDTHSHALL BE BASEDUPON ON-CENTERSPACING IN ACONTINUOUS TRENCH.5' B.R.54"14"6' B.R.60"14"18" B.B.27"7"2' B.B.30"8"3' B.B.36"9"4' B.B.42"11"5' B.B.48"12"6' B.B.54"14"(MnDOT 2571.3H)MIN. 2'-0"MIN. 2'-0"PLANTING HOLE DIMENSIONSHOLE DEPTH FOR B&B AND CONTAINER PLANTS SHALL NOT EXCEED MEASUREMENT FROM ROOTFLAIR TO BOTTOM OF SOIL BALL.PLANT TYPEPLANT SIZE UP TOAND INCLUDING(A) MINIMUM HOLEWIDTH(B) APPROXIMATEHOLE DEPTHCONIFEROUSTREES2' B.B36"10"3' B.B42"11"4' B.B51"13"AT LEAST 2/3 OF ALLCONIFER BRANCHESWILL CONTAINTERMINAL BUDS5' B.B60"13"6' B.B66"15"7' B.B72"16"8' B.B81"18"9' B.B90"20"10' B.B102"21"12' B.B114"24"CONIFEROUSSHRUBS18" B.B.24"7"3' B.B.48"12"(UPRIGHT)CONIFEROUSSHRUBS18" SPR B.B.30"8"2' SPR B.B.36"9"(SPREADING)CONTAINERGROWN PLANTSCELLPACKS / PLUGS6"2.5"2.25" CONT.7"3"3.5" CONT.10"3"4" CONT.11"4"4.5" CONT.13"4"6"/1 QT CONT.15"5.5"1# CONT.18"6"2# CONT.23"7.5"3# CONT.29"8.5"5# CONT.30"11"7# CONT.37"11"15# CONT.44"14"10# CONT.45"15"20# CONT.60"16"25# CONT.72"17"SEEDLINGS6" SEEDLING15"14"9" SEEDLING18"14"12" SEEDLING23"16"18" SEEDLING30"16"2' SEEDLING36"18"VINES1 YR. MED B.R.15"11"1 YR. NO. 1 B.R.17"14'2 YR. MED. B.R.33"12"2 YR. NO. 1 B.R.42"15"INSTALLATION OF PLANTSMULCH PLACEMENTINSTALLATION OF VINESCHAIN-LINK FENCEINPLACE WALL1" x 36" WOOD LATHDRIVEN 12" INTO SOILAT AN ANGLE SO THETOP RESTS SNUGLEYAGAINST THE WALLOR FENCEMULCH CONTINUOUSLYBETWEEN VINES AND5' BEYOND TERMINALVINEFASTEN LOOSELY TOLATH WITHBIODEGRADABLE STRINGFOR PLANTING SOILDETAIL SEE STANDARDPLANTING DETAILS (A)MIN.TYPE OF PLANTSQ. FT. PER PLANTCONIFEROUS TREES2DECIDUOUS ANDORNAMENTAL TREESCONIFEROUS ANDDECIDUOUS SHRUBS,ROSE BUSHS,PERENNIALS,ORNAMENTAL GRASSSPACING x SPACINGVINESSPACING x 22MULCH AREA CALCULATOR = 3.14166" <br />MAX <br />+3XSPADE DIAMETER+1XMACHINE-MOVEDTREES OR SHRUBS1.PULL MULCH BACK NOLESS THAN 3" ANDNO MORE THAN 6"FROM TREES ANDSHRUBS AT THETRUNK OR MAIN STEM.2.SUBSIDING ORDETERIORATING MULCHIS ACCEPTABLETHROUGHOUT THEESTABLISHED PERIOD IFTHE MULCH DEPTH ISMAINTAINED AT AMINIMUM 3" DEPTH.3.ADD MULCH WHENBELOW THE 3"MINIMUM DEPTH, DONOT EXCEED THE 6"MAXIMUM DEPTH.4.MULCH CONTAMINATEDWITH SOIL MUST BEREMOVED ANDREPLACED.CONIFEROUS ANDDECIDUOUS SHRUB (3'min.)CONIFEROUS TREE (RADIUS+3' min.)WALL INSTALLATIONFENCE INSTALLATION15 8 <br />4341 <br />222438412A12"'NOTE: PLANT ACCORDING TO APPLICABLE ROOT STOCK DETAILS TO RIGHTHEIGHT 114DECIDUOUS TREE (3' min.)TRANSPLANT (RADIUS+2' min.)SPACING FROM TRUNKK:\016591-000\Cad\Proposed\016591-000_L-SITE-PLANTING PLAN.dwg 9/1/2020 4:42:22 PM <br />TOTSHEET OFSHEETSANOKA COUNTY, MINNESOTACSAH 34 (Birch Street) ImprovementsAnoka County Highway DepartmentS.A.P. 002-634-003 & S.A.P. 210-020-010XTOTL1.4