Laserfiche WebLink
1. The building shall be constructed in such a way that the exterior to interior sound <br />level attenuation is at least 30 dB(A). <br />2. All housing units shall provide year-round climate control. <br />3. STC 30 windows shall be used for all windows. <br />4. Per page 8 of the Traffic Noise Assessment, exterior wall construction shall <br />consist of: <br />a. APA rated sheathing located on the exterior side of the exterior wall. <br />i. This material will be 7/16" thick and a wood fiber material. <br />b. Exterior wall shall be 2x6 studs with R-21 batt insulation. <br />c. The inside finish shall be 5/8" gypsum board. <br />d. Lap siding shall have a thickness of .354" and be of a wood fibrous <br />material. <br />e. Trim around the windows shall have a thickness of .970" and be of a wood <br />fibrous material. <br />Additional City and Government Agency Review Comments <br />MNDOT <br />MNDOT is reviewing the final plat and will provide comment. <br />Public Safety Comments <br />The Fire Division reviewed the plans and notes the following: <br />1. An emergency vehicle access shall be provided to the north side of the building. <br />a. The developer could potentially upgrade the existing trail to provide <br />emergency vehicle access. <br />2. An addition fire hydrant along the emergency vehicle access shall be added. <br />3. The elevator cars shall be large enough to accommodate ambulance stretchers. <br />The Police Division reviewed the plans and did not identify any public safety concerns <br />that should be addressed. <br />Environmental Board <br />The Environmental Board reviewed the development proposal at their January 4, 2022 <br />meeting. The Board recommended approval with minor revisions required. <br />City Attorney <br />The City Attorney is reviewing the title commitment and final plat. Any comments shall <br />be addressed prior to Council approval of the final plat. <br />Agreements <br />17 <br />