My WebLink
|
Help
|
About
|
Sign Out
Home
Search
06-13-2022 City Council Packet
LinoLakes
>
City Council
>
City Council Meeting Packets
>
2022
>
Searchable Packets
>
06-13-2022 City Council Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2022 6:03:02 PM
Creation date
6/13/2022 3:50:56 PM
Metadata
Fields
Template:
City Council
Council Document Type
Council Packet
Meeting Date
06/13/2022
Council Meeting Type
Regular
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
326
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UP <br />A6.00 <br />1 <br />A6.00 <br />3 <br />A6.01 <br />1 <br />A6.01 <br />2 <br />RESTROOM <br />103 <br />EXAM <br />107 <br />SURGERY <br />116 <br />XRAY <br />119 <br />TREATMENT <br />115 <br />DOG <br />WAITING <br />140 <br />CAT WAITING <br />102 <br />RECEPTION <br />101 <br />EXAM <br />106 <br />EXAM <br />108 <br />CAT WARD <br />118 ISOLATION <br />120 <br />STORAGE <br />117 <br />EXAM <br />104 <br />EXAM <br />105 <br />VESTIBULE <br />100 <br />COMFORT <br />109 <br />LAB <br />114 <br />MECH <br />122 <br />BOARDING <br />RECEPTION <br />110 <br />CORRIDOR <br />111 <br />CORRIDOR <br />113 <br />CLOSET <br />112 <br />A6.10 <br />3 <br />A6.10 <br />4 <br />A6.105 <br />6 <br />1 <br />A7.00 <br />1 <br />A7.00 <br />2 <br />A7.00 <br />2 <br />A7.00 <br />A6.11 <br />1 <br />A6.114 <br />5 <br />6 <br />A6.11 <br />7 <br />1 <br />A7.10 <br />2 <br />A7.10 <br />3 <br />A7.10 <br />1 <br />A7.11 <br />2 <br />A7.11 <br />A6.00 <br />2 <br />A6.00 <br />4 <br />3 <br />A7.11 <br />A5.10 <br />1 <br />W5 <br />A6.118 <br />10 <br />W5 W5 W5 <br />W6 <br />2 <br />A5.12 <br />3 <br />A5.12 <br />A5.11 <br />1 <br />A5.112 <br />3 <br />1 2 3 4 <br />E <br />D <br />C <br />1.1 <br />D.9 <br />3.9 <br />B <br />B.1 <br />0 <br />QQ <br />RR <br />59' - 0 3/4" <br />8 <br />A8.00 <br />4 <br />A7.11 <br />W5 <br />W5 <br />W5 <br />W6 <br />A8.00 <br />9 <br />RE-PACK EXTG BATT INSUL. (R-20 MIN) <br />PROVIDE 3/4" TREATED PLYWOOD SHEATHING AT <br />LOCATIONS WHERE STEEL SIDING HAS <br />BEEN REMOVED - SEE DEMO PLAN. TYPICAL <br />PROTECT EXTG SIDING <br />EXAM <br />139 <br />NOTE: <br />PROVIDE ACRYLIC SEALANT AT <br />ALL SLAB CONTROL JOINTS . SEE <br />STRUCT FOR LOCATIONS. <br />D 1' - 10"A6a <br />B6a <br />A6a <br />LOCATE TREATMENT <br />TOWER AROUND <br />COLUMN. <br />D <br />W <br />BREAK <br />123WAITING <br />124 <br />GROOMING <br />125 <br />CONSULTATION <br />126 <br />KENNELS <br />127 <br />CORRIDOR <br />128 <br />VESTIBULE <br />129 <br />NIC <br />NIC <br />NIC <br />NIC <br />NIC <br />NIC <br />NIC NIC <br />NIC <br />NIC <br />NIC <br />NIC <br />MILLWORK TO REMAIN <br />MODIFY AS REQ'D <br />C1 <br />C2 <br />C2 <br />C2 <br />C2 <br />C2 <br />C2 <br />C4 <br />C2 <br />C2 <br />C2 <br />C3 <br />C3 <br />C3 C3 <br />C2 <br />C5 <br />C5 <br />C3C1 <br />C6 <br />C6 <br />C6 <br />C6 <br />C7 <br />C9 <br />C9C9C9 <br />C10 <br />C11 <br />C12 <br />C13 <br />C16 <br />C16 <br />C16 <br />C18 <br />C27 <br />C27 <br />C41 <br />6' HIGH WOOD SCREENING <br />FENCE. TIE INTO EXISTING <br />SEE 7 & 8 / A8.01 <br />EXAM <br />130 <br />STORAGE <br />134 <br />NIC <br />NIC <br />GROOMING <br />131 <br />CORRIDOR <br />136 <br />CORRIDOR <br />137 <br />NICNIC <br />NIC <br />NIC <br />B3a <br />B6a <br />C1 <br />C17 <br />C15 <br />C3 <br />C3 <br />C3 <br />W1 <br />W2 <br />W3 <br />W2 <br />EX <br />EX <br />EX <br />EX <br />EX EX EX EX <br />C41 <br />C20 <br />C20 <br />C20 <br />CAT ROOM <br />135 <br />C23 <br />C24 <br />C17 <br />C21 <br />C22 <br />C25 <br />C5 <br />A6.00B <br />1 <br />A6.00B <br />2 <br />CONCRETE MECHANICAL PAD <br />GENERAL NOTES - CONSTRUCTION <br />1. THE BUILDING IS OCCUPIED WITH TENANTS. ALL WORK MUST BE DONE IN <br />AN ORDERLY FASHION SO AS NOT TO INCONVENIENCE THE TENANTS IN <br />ANY WAY. LOUD MUSIC, PROFANITY, AND SMOKING IS PROHIBITED ON THE <br />JOB SITE AND IN THE BUILDINGS. SMOKING AREAS WILL BE DESIGNATED <br />BY THE OWNER. <br />2. ACCESS TO ALL ENTRIES AND EXITS MUST BE MAINTAINED IN AN ORDERLY <br />AND SAFE MANNER. <br />3. ALL NEW PARTITIONS TO BE TYPE A3a UNLESS OTHERWISE NOTED. <br />4. PROVIDE IN-WALL BLOCKING FOR INSTALLATION OF FURNITURE AND <br />EQUIPMENT AS REQUIRED, REFER TO FURNITURE PLAN TO REFERENCE <br />LOCATIONS, COORDINATE FINAL LOCATIONS WITH FURNITURE VENDOR. <br />5. PROVIDE EXHAUST FAN AND FLOOR DRAIN AT ALL NEW RESTROOMS. <br />6. NEW PARTITIONS TO ALIGHN WITH EDGE OF EXISTING WINDOW <br />FRAME/SILL OR EXISTING WALLS/COLUMNS UNLESS OTHERWISE <br />DIMENSIONED. <br />7. PLUMBING CONTRACTOR TO PROVIDE DESIGNER WITH CUT SHEETS FOR <br />FINAL APPROVAL OF ALL FIXTURES PRIOR TO ORDERING. <br />8. ANY EXPOSED SINK PIPES SHALL BE WRAPPED TO MEET ACCESSIBILITY <br />REQUIREMENTS. <br />9. ALL NEW WATER SUPPLY PIPING TO BE TYPE 'L' WATER PIPING. <br />10. MECHANICAL CONTRACTOR TO REVIEW ALL THERMOSTAT LOCATIONS <br />WITH DESIGNER PRIOR TO INSTALLATION. <br />11. REUSE EXISTING BLINDS AT ALL EXTERIOR WINDOWS. PULL UP BLINDS <br />AND WRAP PRIOR TO CONSTRUCTION. REPAIR OR REPLACE ANY BLINDS <br />NOT IN PROPER WORKING ORDER. NEW BLINDS MANUAL BLINDS BY <br />OWNER. <br />12. ALL EXISTING EXTERIOR DOORS TO BE RE-KEYED. REMOVE ALL DEAD <br />BOLTS AND LATCHES. ANY EXISTING KNOBS TO BE CHANGED TO ADA - <br />COMPLIANT LEVER HARDWARE. ENSURE THAT EXISTING HARDWARE IS IN <br />GOOD WORKING CONDITION, REPAIR AND REPLACE AS NECESSARY. <br />3/16" = 1'-0" <br />CONSTRUCTION PLAN - LEVEL 011 <br />Ryan Schroeder <br />NO. Print History Date <br />#50047 <br />Signature : <br />Name : <br />Registration : <br />Project <br />Checked <br />Drawn <br />Project Contact : <br />Phone Number :952-541-9969 <br />I hereby certify that this plan was prepared <br />by me or under my direct supervision and <br />that I am a duly licensed architect under the <br />laws of the State of Minnesota. <br />Ryan Schroeder <br />21303 <br />LAM <br />RAS <br />OTTER LAKE ANIMAL <br />CARE CENTER <br />CONSTRUCTION PLAN <br />- LEVEL 01 <br />A1.11 <br />OTTER LAKE <br />ANIMAL CARE <br />CENTER <br />6848 OTTER LAKE RD, <br />HUGO, MN 55038 <br />LEGEND - CONSTRUCTION <br />EXISTING CONSTRUCTION TO REMAIN <br />EXISTING PARTIAL HEIGHT CONSTRUCTION TO REMAIN <br />NEW FULL HEIGHT CONSTRUCTION - REFER TO PARTITION TYPE <br />NEW PARTIAL HEIGHT CONSTRUCTION - REFER TO PARTITION TYPE <br />NEW CONSTRUCTION - REFER TO PARTITION TYPE <br />NEW RATED CONSTRUCTION TO STUCTURE - REFER TO PARTITION TYPE <br />NEW INSULATED CONSTRUCTION - REFER TO PARTITION TYPE <br />PLAN NOTES <br />NO.DESCRIPTION <br />C1 PROVIDE FLOOR DRAIN, LOCATION APPROXIMATE, TO BE COORDINATED IN FIELD <br />WITH DESIGN/BUILD PLUMBING CONTRACTOR. SLOPE SLAB AS REQUIRED. <br />C2 NEW MILLWORK BY OWNER, PROVIDE BLOCKING AS REQUIRED. SEE ELEVATIONS <br />& SECTIONS FOR DETAILED ELEVATIONS. <br />C3 NEW MANUALLY OPERATED ROLLER SHADES BY OWNER <br />C4 NEW FRONT DESK. SEE DETAILS ON SHEET A6.10 <br />C5 PROVIDE WAITING AREA BENCHING, DESIGN TO BE DETERMINED WITH OWNER, <br />DETAILS TO FOLLOW. <br />C6 INSTALL OWNER PROVIDED NEW FOLD DOWN EXAM TABLES IN EXAM ROOMS. <br />PROVIDE (QTY 2) 2X10'S STACK ON END, IN WALL, FOR SUPPORT BLOCKING. <br />COORDINATION LOCATION OF BLOCKING WITH TABLE. <br />C7 STEEL COLUMN - SEE STRUCTURAL PLANS FOR DETAILS. PROVIDE 1 LAYER OF <br />5/8" TYPE 'X' GYP BD <br />C9 PATCH AND REPAIR NEW OPENING, PROVIDE 5/8" GYP BD ON FRAMING W/ EXP <br />JOINT @ NEW JAMB OPENINGS AS REQUIRED. <br />C10 INFILL EXISTING WINDOW OPENING, SET TO BE DEMOLISHED, TO MATCH EXISTING <br />ADJACENT WALL CONDITION. PATCH AND REPAIR WALL AS REQUIRED. <br />C11 RECOVERY KENNELS BY OWNER <br />C12 SCALE BY OWNER, PROVIDE POWER & DATA PER REQUIREMENTS BY SCALE <br />MANUFACTURER. <br />C13 FURNISH AND INSTALL JANITORIAL MOP SINK & FAUCET W/ HOSE OCNNECTIONS. <br />C15 NEW CORNER GAS FIREPLACE <br />C16 SINK BY DESIGN/BUILD PLUMBING CONTRACTOR - VERIFY SPECIFICATION & USE <br />W/ OWNER <br />C17 NEW PASS-THROUGH WINDOW WITH GLASS SHELVING <br />C18 PROVIDE WATER COOLER, SEE "GENERAL RESTROOM NOTES" FOR DESIGN <br />INTENT SPEC. <br />C20 NEW FOOTING, COLUMN AND FLOOR SURFACE FLUSH WIH EXISTING CONCRETE <br />SUBSTRATE. SEE STRUTURAL. PATCH EXISTING WALLS AS REQUIRED. <br />C21 NEW CONCRETE FLOOR FLUSH WITH EXISTING. PATCH VAPOR BARRIER AS <br />REQUIRED <br />C22 RELOCATE X-RAY MACHINE BY OWNERS CONSULTANT. GC TO RELOCATE <br />UTILITIES AS REQUIRED. VERIFY WITH LAKE SUPERIOR X-RAY <br />C23 INFILL EXISTING DOOR OPENING FLUSH WITH ADJACENT FINISHES. <br />C24 GC TO PROVIDE IN-WALL WASHER AND DRYER BOXES/UTILITIES. RELOCATE <br />WASHER AND DRYER <br />C25 PATCH WALL AND BASE. <br />C27 PROVIDE STAINLESS STEEL SINK W/ HIGH NECK FAUCET. PROVIDE BRADLEY <br />819-2009 FAUCET MOUNTED EYE WASH STATION. <br />C41 PROVIDE 1" ISOLATION JOINT AT NEW WALL CONNECTION TO EXISTING <br />STRUCTURE <br />NO. Description Date <br />N <br />SITE PLAN REVIEW 03-24-22 <br />SITE PLAN REVIEW - UPDATE 04-11-22
The URL can be used to link to this page
Your browser does not support the video tag.