Laserfiche WebLink
Services (MCES). <br />City Water (CWAC) $1,473.00 Per SAC Unit. <br />C. Surface Water Management Area Charges <br />The City established a trunk area charge to uniformly distribute the costs <br />of public trunk surface water infrastructure and water quality <br />improvements. The Surface Water Management Charge shall be based on <br />developable acreage. <br />1. <br />Sanitary Sewer Trunk Unit Fee ($1,630/unit; 2.92 units/Acre) <br />Acres* <br />6.49 <br />$30,888.50 <br />2. <br />City Sewer Availability Fee ($1,525/SAC Unit) <br />TBD** <br />3. <br />Water Trunk Unit Fee ($2,34 1 /unit; 2.92 units/Acre) <br />6.49 <br />$44,361.95 <br />4. <br />City Water Availability Fee ($1,473/SAC Unit) <br />TBD** <br />5. <br />City Surface Water Management Fee ($11,073/ Acre) <br />6.49 <br />$71,863.77 <br />Total Estimated (Budget) Developer Fees <br />$147,114.22 <br />*Acrea <br />a used for calculations is the total site area (14 18 acres) reduced <br />b the <br />g y <br />conservation easement area (7.26 acres) and the permanent trail easement area <br />(0.43 acres) <br />**Paid at the time of Building Permit based on MCES unit determination <br />D. Metropolitan Council Environmental Services (MCES) Sewer Availability <br />Charges (SAC) are in addition to the fees referenced above and shall be <br />determined by MCES, and shall be paid with the Building Permit. <br />IV. RECORD DRAWINGS. <br />a. Upon project completion, Developer shall submit record drawings, in <br />electronic format, of all public and private infrastructure improvements, <br />including grading, sanitary sewer, water main, storm sewer facilities, and roads, <br />constructed by Developer. The as -built survey must include, but is not limited <br />to, proposed and final contours with adequate elevation shots to show <br />conformance, property irons (to be exposed in field), low floor and low <br />opening elevations, and the 100-Year High Water Level (HWL) of all ponds, <br />lakes, and wetland areas. The files shall be drawn in Anoka County NAD 83 <br />Coordinate system and provided in both AutoCAD .dwg and Adobe .pdf file <br />formats. The plans shall include accurate locations, dimensions, elevations, <br />grades, slopes and all other pertinent information concerning the complete work. <br />The Developer shall also submit certified compaction testing results for the <br />site grading operations. <br />Kwik Trip Site Performance Agreement page 4 of 11 <br />