ELECTRICAL DRAWING INDEXE001ELECTRICAL SYMBOLS LEGENDE101 EXISTING TENNIS COURT AREA / NEW PARKING LOT - ELECTRICALE102 EXISTING EAST PARKING LOT / NEW TENNIS COURTS - ELECTRICALE103 NEW PARKING LOT AND TENNIS COURTS - PHOTOMETRICSUNDERGROUND ELECTRICAL CONDUITELECTRICAL SYMBOLS LEGENDJUNCTION BOXPOLE LIGHT, ARM MOUNTEDLIGHTINGPOWERPOLE LIGHT, TOP MOUNTEDDESCRIPTIONSYMBOLANNOTATIONSEE LIGHT FIXTURE SCHEDULEUPPER CASE LETTER INDICATES FIXTURE TYPELOWER CASE LETTER INDICATES CONTROLNUMBER INDICATES CIRCUITSHEET NOTESCALESHEET#TITLEDETAIL VIEWPORT TITLE#SHEET___SECTION CUTREVISION INDICATORCU COPPERKVA KILOVOLT-AMPEREKW KILOWATTLTS LIGHTSHEIGHTHTH HOTHD HEAVY DUTYGROUND FAULTGFIG GROUNDFUSEFE EMERGENCYELECTRICAL CONTRACTORECINTERRUPTING CURRENTCBIC CIRCUIT BREAKERCB CIRCUIT BREAKERCONDUITCAMPERE INTERRUPTING CURRENTABOVE FINISHED FLOORAVAILABLE FAULT CURRENTAMPERESAICAFFAFCANF NON-FUSEDMAIN SWITCHBOARDMSBWP WEATHERPROOFWIREWVA VOLT-AMPSV VOLTUNO UNLESS NOTED OTHERWISEUG UNDERGROUNDSES SERVICE ENTRANCE SECTIONP POLEPHASEPH, ØN3R NEMA 3RN1 NEMA 1N NEUTRALMOUNTINGMTGMFR MANUFACTURERMLO MAIN LUG ONLYMCB MAIN CIRCUIT BREAKEREX EXISTINGAL ALUMINUM EMT ELECTRICAL METALLIC TUBINGENT ELECTRICAL NON-METALLICCIRCUIT INTERRUPTERGFCIORRMC RIDGID METAL CONDUITABBREVIATIONS FOR ELECTRICALTUBINGAHJ AUTHORITY HAVING JURISDICTIONCD CANDELAAMP-FUSEAFNO.ABOVE COUNTERACWIRE GUARDWGHOMERUN - TEXT DESIGNATES PANEL AND CIRCUITNUMBERS. NUMBERS SEPARATED BY COMMAS INDICATESEPARATE BREAKERS. NUMBERS SEPARATED BY HYPHENINDICATE MULTI-POLE BREAKERS. CONDUCTORS SHALL BE#12 AWG IN A 3/4" CONDUIT UNLESS NOTED OTHERWISE.LONG HASH MARKS INDICATE NEUTRAL CONDUCTORS,SHORT HASH MARKS INDICATE NUMBER OF PHASECONDUCTORS. NO HASH MARKS INDICATE 3#12 IN A 3/4" C.PROVIDE A CODE-SIZED GROUND IN EACH CONDUIT.NOTES:LIGHT FIXTURE SCHEDULETYPEDESCRIPTIONMANUFACTURERCATALOG NUMBERVOLT/WLAMPSMOUNTING LOCATIONNOTES1.QTYTYPE1,2LITHONIA.DSX2 LED P2 40K T2S MVOLT SPA DDBXDMVOLT 185WPOLESITE..2. MCGRAW-EDISON GALLEON SERIES AND BEACON VIPER SERIES EQUIVALENT PRODUCTS ARE APPROVED FOR BIDDING.PROVIDE 5-INCH SQUARE, 25-FT STRAIGHT STEEL POLE RATED FOR 110 MPH WIND LOAD. PROVIDE VIBRATION DAMPENERS, ANCHOR BOLTS, AND BASE COVER. COLOR TO MATCH FIXTURE.SINGLE HEAD PARKING AREA POLELUMINAIRE, TYPE 2 DISTRIBUTIONDARK BRONZEAA224,127L LED4000K1,2LITHONIA.DSX2 LED P3 40K T5W MVOLT SPA DDBXDMVOLT 217WPOLESITE..SINGLE HEAD PARKING AREA POLELUMINAIRE, TYPE 5 DISTRIBUTIONDARK BRONZEAA529,144L LED4000KELECTRICAL SPECIFICATIONS260000 - GENERAL ELECTRICAL REQUIREMENTSA. General and supplementary conditions and Division 1 shall apply to all work specified herein.B. Scope of work: Complete all electrical work shown on these drawings and specified herein. Provide all equipment necessary to completethe work.C. The work indicated on these drawings and specifications consists of providing all labor, supervision, equipment, and materials necessaryfor and incidental to the installation of the complete electrical systems required by these drawings.D. Obtain and pay for all licenses and permits.E. The entire installation of the electrical systems shall be made in accordance with all ordinances, laws, regulations, and codes applicable tothe work involved. If, in any instance, the plans conflict with such codes, the code shall take preference. This does not relieve theContractor from complying with any requirements of the drawings that may be in excess of codes and not contrary to same. Applicablecodes include, but are not limited to, the following :1. National Electrical Code.2. Local codes with amendments.3. National Fire Protection Association (NFPA).4. International Building Code (IBC).5. International Fire Code (IFC).6. Life Safety Code NFPA 101.7. OSHA.F. The Contractor shall visit the site prior to submitting a bid to become familiar with the job conditions. No extra payment will be allowed foritems that could have been anticipated from a site visit.G. Jobsite Safety: This Contractor shall be solely responsible for the safety of their employees, personnel, and equipment throughoutconstruction and for both normal working hours and after hours. It is the responsibility of the Contractor to implement adequate safetymeasures and to enforce those measures.H. All material shall be new, free of defects, of the quality specified, and conform to NFPA, NEMA, UL, and ANSI standards in every casewhere such a standard has been established for the particular type of material.1. Equipment shall be listed by UL, ETL, or as approved by the Authority Having Jurisdiction.2. Equipment shall be seismic rated as required for the installation.I. Where the term "Provide" is used it shall mean to furnish and install complete ready for use.J. Shop drawing data shall include, but not be limited to: manufacturer, catalog number, and trade name; electrical characteristics andperformance data; dimensions; descriptive material; and other items as specified herein. Provide shop drawings as required by GeneralContractor.1. 260533: In-Ground Pullboxes.2. 265000: Light Fixtures and PolesK. This Contractor shall make provisions for delivery and safe storage of materials during all phases of construction. Equipment shall bestored in the same type of environment it is rated for.L. All work shall be neat, follow industry standards (NECA), and complete in both effectiveness and appearance. All work shall be executedby persons licensed and skilled in the trade.M. This Contractor shall guarantee all equipment, material, and workmanship for a period of one year from date of final certificate. Anydefects in electrical equipment, workmanship, or material that may appear to cause trouble of any kind shall be remedied at no cost to theOwner during guarantee period.N. The drawings indicate the extent and general layout of the electrical systems and are intended to be as accurate as planning candetermine at the scale shown for estimating purposes only. Field verification of dimensions, locations, and construction details is required.Review appropriate drawings, make field measurements and adjust work to suit the conditions encountered. Electrical drawings arediagrammatic but shall be followed closely as actual construction of other trades will permit.O. Coordinate work with building elements and other trades. Refer to Architectural, Structural, and Mechanical Drawings.P. This Contractor shall maintain one set of drawings at the job site to be used as a master copy for record drawings. All changes anddeviations shall be clearly marked and noted by colored pencil. These drawings shall be submitted to the Architect upon projectcompletion.Q. Cutting, fitting, and repairing which may be required for this work shall be done by skilled personnel. When cutting is required it shall bedone in a manner as to not weaken walls or floors. Concrete and masonry shall be cut with a diamond core-drill or concrete saw. Whenpatching is required, it shall be completed to match existing finishes.R. This Contractor shall be responsible for trenching, excavating, and backfilling as required for electrical work included in this project.Excavation shall be backfilled with appropriate material and thoroughly tamped. Provide all shoring and bracing necessary to performwork and as required for safety.S. This Contractor shall be responsible for replacing and/or repairing items damaged (i.e. streets, sidewalks, existing floors, finished areas,etc.) coincidental to work being performed.T. Seal all penetrations through walls and floors with appropriate sealant. Fire rated sealant shall be used to seal penetrations throughfire-rated walls/floors.U. Provide proper installation as required to comply with seismic zone and local requirements.V. Test all equipment installed for proper operation. Provide written verification of test results of various systems as required by inspectingauthorities and as specified herein.260519 - WIRE AND CABLEA. Conductors shall be annealed copper having a conductivity of not less than 98% of pure copper and shall be properly insulated for 600volt service. Insulation shall be type THHN/THWN or XHHW/XHHW-2.B. Conductors No. 10 AWG and smaller shall be solid. Conductors No. 8 AWG and larger shall be stranded.C. The minimum conductor size shall be No. 12 AWG, unless noted otherwise on drawings. Larger sizes shall be used as indicated ondrawings or as required by the NEC.D. Connectors shall be solderless, screw-on, pressure cable type, 600-volt, 105 degree C, with integral insulation skirt to completely coverthe wire strips.E. Installation: Pull all cables in a single conduit together. Splices and terminations shall be mechanically and electrically secure. Makesplices in outlet boxes or junction boxes only.260526 - GROUNDINGA. Provide a ground conductor in each raceway. Ground conductors shall be insulated copper with the same insulation type as otherconductors contained within the raceway. Provide ground bushing/clamps as required by Code .B. Ground systems in accordance with the NEC. Install a code-sized insulated grounding conductor in all raceways for power circuits .260533 - RACEWAYS AND BOXESA. EMT shall be galvanized on the outside and coated on the inside with a protective lubricant and interconnected with water-tightcompression ring type steel fittings. Set-screw fittings are acceptable indoors where not susceptible to water.B. Rigid Steel: Hot dipped galvanized and interconnected with watertight compression fittings.C. PVC Conduit: Schedule 40 heavy wall type, 90 degree C wire rated for exposed, encased, and underground applications. Interconnectwith solvent welded fittings.D. Liquid-tight flexible conduit: Galvanized with a PVC jacket with rain-tight compression ring type steel fitting. Use for motor connections.E. Application: Use appropriate raceway for the application and as required and/or allowed by Code. Use flexible conduit for final connectionto motors and equipment where equipment vibration is present.F. Install and support raceways in accordance with manufacturer's requirements and the NEC.G. Boxes: 4-inch square, 14 gauge galvanized steel with knockouts except for exterior locations. Exterior shall be weatherproof type,suitable for the application with or as shown on the drawings.H. Junction and pull boxes shall be code-gauge (or heavier if required for the application) galvanized sheet steel with screw type covers.Covers for flush junction boxes shall match surrounding device covers. Pull boxes installed in finished spaces shall be the flush-mounttype with trim, hinged door, and flush latch and lock. weather proof covers. Boxes shall be sized per Code.I. Equipment enclosures shall be sized appropriately for equipment it encloses and to comply with the NEC. Enclosures shall be asmanufactured by Hoffman or equivalent.265000 - LIGHT FIXTURESA. Fixtures indicated on fixture schedule indicate the type and quality of fixtures to be provided. Equivalent products by other manufacturersand fixture substitutions is only permitted based on Engineer approval.B. Electrical Contractor shall receive and install light fixtures indicated to be provided by Owner.C. Fixtures shall be installed per manufacturers recommendations and in compliance with applicable codes. Provide all necessaryaccessories including j-boxes, mounting screws, extra supports, etc. for a complete system.D. Provide poles as specified on the drawings. Poles shall be manufactured and installed to withstand wind loads for the area in whichinstalled or greater if noted on the Light Fixture Schedule.1. Poles shall be equipped with a handhole and ground lug.2. Provide anchor bolts and base covers for outdoor and site lighting. Anchor bolts shall be concealed and not visible after installation.E. Store and protect poles from damage. Inspect poles prior to installation for damage, flaws in paint, etc. Provide factory touch-up paint torepair scratches, etc. to original condition.F. Provide all equipment necessary to properly install light pole bases, light poles, and fixtures.K. If required be local jurisdiction of project, Contractor/Manufacturer shall provide pole base designed by a professional structural engineerlicensed in the state of project location. Pole base design shall be applicable to project location and comply with state and localrequirements.L. Clean all fixtures prior to final acceptance. Test all fixtures for proper operation. Replace defective fixtures.SKID RESISTANTSURFACE4 3/4" (121 mm) X4- 5/8" (117 mm)KNOCKOUTS (6)3/8-16 UNCSTAINLESS STEELHEX HEAD BOLTW/WASHER (2)PROVIDE BOX EXTENSIONAS REQUIREDCOVER1/2" X 4"PULL SLOTMOUSEHOLES(4) (102 mm) X 4" (102 mm)ELEC23 1/4"13 3/4"23 3/4"14 1/4"D11 3/4"21 1/4"25"15 1/2"A11 3/4"21 1/4"NOTE:BOX IS QUAZITE PG1324BBOR APPROVED EQUIVALENTCONTRACTORSET BY ELECTRICALFURNISHED ANDANCHOR BOLTSPVC CONDUITCONCRETE BASE24" ROUND24" MIN7'-0"PVC CONDUITELECTRICAL CONTRACTOR3/4" CHAMFER BYGRADE24"REINFORCEMENT BARS4#5 VERTICAL AND#4 HORIZONTAL 12" ONCENTER FOR ENTIRELENGTH OF BASEPROVIDE BASE COVERIN POSTGROUND LUGPOST LIGHT ANDBASE BY ECHANDHOLE25'-0"27'-0"5/8" x 10-FT COPPERGROUND RODLED FIXTUREFULLY CUTOFFNOTE:MATCH EXISTING BASEHEIGHT ABOVE GRADE ANDCHAMFERED EDGESDRAWING NUMBERCPROJECT # 2023-02DRAWN BYDATE 02-07-2023DRAWING TITLEDateRevision DescriptionDRAWINGSCONSTRUCTIONRO/JBMADISON, WIMILWAUKEE, WIMAPLE GROVE, MNTHIS DRAWING IS PROPERTY OFNEXUS SOLUTIONS, LLC. USE OR REPRODUCTIONWITHOUT WRITTEN PERMISSION IS PROHIBITED.Nexus Solutions, LLCJeffrey A. BlakeI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, ORREPORT WAS PREPARED BY ME OR UNDER MY DIRECTSUPERVISION AND THAT I AM A DULY LICENSEDPROFESSIONAL ENGINEER UNDER THE LAWS OF THESTATE OF MINNESOTA.PRINTED NAME:SIGNATURE:DATE: REG. NO.41083CHECKED BYJABCENTENNIAL MIDDLE SCHOOL ISD #12
<br />TENNIS COURT RELOCATION
<br />AND PARKING LOT ADDITION
<br />399 ELM STREET
<br />LINO LAKES, MN 5501402/07/2023Design, P.C.ElectricalElectrical Consulting Engineers6885 Sycamore Ln N, Suite 210Maple Grove, MN 55369763.486.0965jeff@jbelectricaldesign.comJBED Proj. No. 2023-02c 2023 by JB Electrical Design, PCE001ELECTRICALSYMBOLS LEGENDNO SCALEE0011IN-GROUND PULLBOX DETAILNO SCALEE0012POLE BASE DETAIL
|