My WebLink
|
Help
|
About
|
Sign Out
Home
Search
06-12-2023 City Council Packet
LinoLakes
>
City Council
>
City Council Meeting Packets
>
2023
>
Searchable Packets
>
06-12-2023 City Council Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2023 8:30:27 AM
Creation date
6/9/2023 8:17:02 AM
Metadata
Fields
Template:
City Council
Council Document Type
Council Packet
Meeting Date
06/12/2023
Council Meeting Type
Regular
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
336
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6 <br />Manufactured Stone Veneer Montana Jasper (dark dray) <br />Fiberglass Shingles Charcoal (black) <br />Standing Seam Roof Metallic Silver (gray) <br />The exterior materials, colors, and percentages are compliant with performance <br />standards. <br />The building height is 33’ 8” to the top roof peak which is less than that maximum 45 ft <br />allowed. <br />A 150sf trash enclosure/storage area is proposed on the north side of the building. <br />Construction details provided on Sheet A5.3 indicate painted smooth face CMU and <br />painted rock face CMU to compliment the principal building. The swing gate is <br />composite decking pickets that has at a minimum opaqueness of at least 80%. The trash <br />enclosure is 6’ 2” in height and has a standing seam metal roof. The trash enclosure <br />meets performance standards. <br />Per Sheet A3.3, the rooftop mechanical equipment is screened by 3’4” high parapets. <br />Per Sheet A0.2, an automatic sprinkler system shall be provided throughout the building <br />for fire suppression. <br />Outdoor Lighting <br />Per City Code Section 1007.043(6)(d), no light source shall exceed 1.0 foot candle onto <br />right of way or 0.4 foot candle onto adjacent property. Per Page M, Photometric Plan, no <br />light sources exceed 1.0 foot candle along Apollo Drive and Lilac Street and are <br />compliant. No light sources exceed 0.4fc along the east lot line. Light sources do max at <br />4.4 foot candle within the shared parking lot because a light pole is located in the island <br />on the lot line which is acceptable for safety purposes. <br />The parking lot light poles are 20ft tall on 3ft bases for a total height of 23 ft which is less <br />the 45ft maximum allowed. The parking lot light fixtures are down lit and cutoff as <br />required by city code. Decorative downlit wall mounted lights are provided on the <br />exteriors of the building. <br />The outdoor lighting meets performance standards. <br />Off-Street Parking Requirements <br />Per City Code Section 1007.044(6), day care facilities require one (1) space for each <br />300sf of floor area. Floor area is 10% of the gross area. Parking calculations will be based <br />on the first floor gross area because the second floor is only being used for storage.
The URL can be used to link to this page
Your browser does not support the video tag.