Laserfiche WebLink
FIRST FLOOR <br />100' - 0" <br />L AN <br />WAREHOUSE <br />100 <br />1/4" / 12" <br />FJ <br />T.O. ROOF (LOW) <br />123' - 9" <br />T.O. ROOF (HIGH) <br />126' - 2" <br />MIXING <br />101 <br />A4.1 <br />6 <br />SIM. <br />FIRST FLOOR <br />100' - 0" <br />T.O. EXIST. CMU <br />124' - 0" <br />146 <br />WAREHOUSE <br />100 <br />A4.1 <br />3 <br />4 <br />A4.1 <br />5 3 24.15.9 1.1 <br />FIRST FLOOR <br />100' - 0" <br />T.O. EXIST. CMU <br />124' - 0" <br />6 5.9 <br />EXISTING ROOF AND <br />EXTERIOR WALL <br />BUTLER ROOF TRIM TO <br />EXISTING PARAPET <br />CONNECTION DETAILS <br />BY MFR., TYP. CUT <br />DOWN EXIST. PARAPET <br />AS REQUIRED. <br />METAL BUILDING COLUMN, <br />SIZE AND SPACING VARIES. <br />SEE STRUCT. AND MFR. PLANS <br />METAL ROOF ASSEMBLY: <br />STANDING SEAM METAL <br />PANEL W/ THERMAL BLOCKS <br />BATT INSULATION, R-34 MIN. <br />VAPOR BARRIER LINER <br />NEW HEADER - SEE STRUCT. <br />EXISTING SLAB AND <br />FOUNDATION WALL <br />NEW COILING DOOR - SEE <br />PLANS <br />CONCRETE SLAB - <br />SEE STRUCTURAL <br />FIRST FLOOR <br />100' - 0" <br />L <br />A4.1 <br />5 <br />LOADING DOCK SEAL - <br />VERIFY MODEL W/ OWNER <br />LOADING DOCK BUMPER - <br />VERIFY MODEL W/ OWNER <br />LOADING DOCK LEVELER - <br />VERIFY MODEL W/ OWNER <br />OVERHEAD DOOR <br />PRE-ENGINEERED METAL <br />BUILDING WALL ASSEMBLY: <br />BUTLER TEXTUREWALL <br />INSULATED METAL PANEL, <br />R-19 MIN. <br />METAL GIRTS AS REQ'D. BY <br />MFR. <br />INSULATION AT GIRTS <br />SHOWN PER MFR. SPEC. SEE <br />MFR. DRAWINGS <br />METAL ROOF ASSEMBLY: <br />STANDING SEAM METAL <br />PANEL W/ THERMAL BLOCKS <br />BATT INSULATION, R-34 MIN. <br />VAPOR BARRIER LINER <br />PREFINISHED BUTLER <br />GUTTER / DOWNSPOUT <br />DRAINAGE SYSTEM <br />1/4" / 12" <br />M <br />METAL BUILDING COLUMN, <br />SIZE AND SPACING VARIES. <br />SEE STRUCT. AND MFR. PLANS <br />GRADE - SEE CIVIL <br />SEE STRUCTURAL <br />BOLLARD - SEE PLANS <br />FIRST FLOOR <br />100' - 0" <br />VERIFY W/ DOCK LEVELER MFR. LEVELER MFR.VERIFY W/ DOCKFOUNDATION WALL - <br />SEE STRUCT. <br />STEEL ANGLE - SEE <br />STRUCT. <br />DOCK BUMPER - <br />VERIFY MODEL W/ <br />OWNER <br />POURED CONC. PIT <br />FLOOR AND WALLS - <br />SEE STRUCT. <br />DOCK LEVELER - <br />VERIFY MODEL W/ <br />OWNER <br />STEEL ANGLE <br />BEYOND <br />STEEL ANGLE - SEE <br />STRUCT. <br />POURED CONC. FLOOR <br />SLAB - SEE STRUCT. <br />RIGID INSULATION <br />RIGID INSULATION, EXTEND <br />4' HORIZONTALLY <br />FIRST FLOOR <br />100' - 0" <br />BUTLER WALL SYSTEM TO <br />FLOOR SLAB CONNECTION <br />DETAILS BY MFR., TYP. <br />2" RIGID INSULATION, R-10 MIN. <br />CONC. FOUNDATION WALL AND <br />FOOTINGS - SEE STRUCT. <br />GRADE <br />GRANULAR FILL - SEE STRUCT. <br />COLUMN PIER AND <br />FOUNDATION BEYOND - <br />SEE STRUCT. <br />PROJECT NO. <br />© 2023 Copyright Studio EA, LLC. All rights reserved. <br />STUDIO EA <br />76 Coulee Road <br />Hudson, WI 54016 <br />715.386.8303 <br />WeAreStudioEA.com <br />PERMIT SET <br />A4.1 <br />SECTIONS AND <br />DETAILS 424 APOLLO DRIVELINO LAKES, MN 55014RICE INDUSTRIES23-5000 <br />1/8" = 1'-0"1 BUILDING SECTION <br />1/8" = 1'-0"2 BUILDING SECTION <br />1/2" = 1'-0"3 W ALL SECTION @ EXISTING <br />1/2" = 1'-0"4 WALL SECTION @ DOCK DOOR <br />1" = 1'-0"5 DETAIL @ DOCK LEVELER <br />1" = 1'-0"6 TYP. FOUNDATION <br />RELEASE DATE <br />PERMIT SET 2023-09-29 <br />CERTIFICATION <br />I HEREBY CERTIFY THAT THIS PLAN <br />SPECIFICATION, OR REPORT WAS PREPARED BY <br />ME OR UNDER MY DIRECT SUPERVISIONS AND <br />THAT I AM A DULY REGISTERED ARCHITECT <br />UNDER THE LAWS OF THE STATE OF MINNESOTA <br />DATE <br />NAME <br />SIGNATURE <br />NUMBER: 46295 <br />Nathan W Burt <br />2023-09-29 <br />21