Laserfiche WebLink
(C .S .A .H N O . 2 3 )PARK COURTLAK <br />E <br /> <br /> <br /> <br />D <br />R <br />I <br />V <br />E DECIDUOUS TREEPLANTING(TYP)D1L-501CONIFEROUS TREEPLANTING(TYP)A1L-501SHRUBPLANTING(TYP)D3L-501EDGING ATPLANTINGBED (TYP)A3L-501MAINTENANCE STRIP(TYP)E3L-501EXISTING FENCE4' HIGH BERM4' HIGH BERMSPADEEDGE(TYP)A5L-501TREE REPLACEMENTSEE SHEET L-010 TREEPRESERVATION PLAN FORSUMMARY (TYP)TREE REPLACEMENTSEE SHEET L-010 TREEPRESERVATION PLANFOR SUMMARYEXISTING TREES REPLACED SHRUBSSNOWSTORAGESNOWSTORAGETREE REPLACEMENTSEE SHEET L-010 TREE PRESERVATIONPLAN FOR SUMMARYMODULAR BLOCKRETAINING WALLB4L-5018' CHAIN LINKSECURITY FENCE(TYP)B4L-501ROCK STRIP BETWEEN CURBAND RETAINING WALLSNOW STORAGE IF PROOFOF PARKING IS BUILTPRIMARY SNOW STORAGESPADED TREESFROM EXISTINGVEHICULARHARDSCAPE(TYP)SPADED TREESFROM BUFFER &SCREEN (TYP)REPLACEDSHRUBS(TYP)FILL STUMP GRILDING AREASWITH SOIL AS NEEDED.APPLY TOPSOIL & RESEED.BERM RE-ESTABLISHMENTSPOT TREATMENT ALL NOXIOUS WEEDSUSING APPROVED BOARDLEAF HERBICIDE.DO NOT DISPOSE NOXIOUS WEEDS.REPAIR & OVERSEED BERM WITH NO MOWLAWN SEEDING4' CHAIN LINKSECURITY FENCE(TYP)XX <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />XXXXXXXXXXXXXXXXXXXX <br />9030SCALE IN FEET Know what's below. Call before you dig. RA1LANDSCAPE PLAN1" = 30'L-102LANDSCAPE PLANAMC23004PROJECT NO.SHEETCERTIFICATIOND E S I G NCIVIL ENGINEERING | LANDSCAPE ARCHITECTURE310 4TH AVE SOUTH, SUITE 1006MINNEAPOLIS, MN 55415www.elanlab.comp 612.260.7980f 612.260.7990123456EDCBA <br />NOT FORCONSTRUCTION I hereby certify that this plan was prepared by me, orunder my direct supervision, and that I am a dulyLicensed Landscape Architect under the laws of thestate of MINNESOTA.Pilarsinee SaraithongREGISTRATION NO.01/25/2024DATE45059RESPONSE TO CITYCOMMENTS01/25/2024LINO LAKESINDUSTRIAL ANDSTORAGE CENTERLINO LAKES, MINNESOTAISSUEDATESHEET INDEXPROJECTAMCON6121 BAKER RD, SUITE 101MINNETONKA, MINNESOTA 55345651-379-9090LARIAT COMPANIES INC.8345 Crystal View Rd. #200Eden Prairie, Minnesota, 55344OWNERLEGENDSOD 3,975 SF.NO MOW LAWN SEEDING 27,435 SF.NATIVE SEEDING 7,925 SF.LANDSCAPE NOTES1.LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR FINISHED GRADING ANDPOSITIVE SURFACE DRAINAGE IN ALL LANDSCAPE AREAS. LANDSCAPECONTRACTOR MUST ENSURE THAT THE FINAL GRADES ARE MET ASSHOWN ON GRADING PLAN. IF ANY DISCREPANCIES ARE FOUND,IMMEDIATELY NOTIFY LANDSCAPE ARCHITECT FOR RESOLUTION.2.ALL PLANT MATERIALS ARE TO CONFORM WITH STATE & LOCALCONSTRUCTION STANDARDS AND THE CURRENT ADDITION OF THEAMERICAN ASSOCIATION OF NURSERYMEN STANDARDS. ALL PLANTMATERIALS ARE TO BE HEALTHY, HARDY STOCK, AND FREE FROM ANYDISEASES, DAMAGE, AND DISFIGURATION.3.QUANTITIES OF PLANTS LISTED ON THE PLAN ARE TO GOVERN ANYDISCREPANCY BETWEEN THE QUANTITIES SHOWN ON THE PLANTSCHEDULE AND PLAN. PLACE PLANTS IN PROPER SPACING FOLLOWINGLAYOUT FIGURES.4.TOPSOIL TO BE MNDOT 3877.2B LOAM TOPSOIL BORROW FORLANDSCAPED AREAS AND PLANTING BEDS. PROVIDE ROOTING TOPSOILBORROW MNDOT 3877.2E FOR PLANT RESTORATION, WATER QUALITY, ANDFILTRATION PLANTING.5.PLANTING SOIL TO BE CONSISTED OF 50% SELECT TOPSOIL BORROW(MNDOT 3877) AND 50% GRADE 2 COMPOST (MNDOT 3890). PLANTING SOILTO HAVE A PH BETWEEN 6.5-7.5, BE FREE OF CHEMICAL CONTAMINANTS,DEBRIS, LARGE ROCKS GREATER THAN 1/ 2" DIAMETER, AND FRAGMENTSOF WOOD. SUBSOIL SHALL BE SCARIFIED TO A DEPTH OF 4" BEFOREPLANTING SOIL IS SPREAD.6.SPREAD PLANTING SOIL AT MINIMUM EIGHTEEN (18) INCH DEEP IN ALLPLANTING BEDS PRIOR TO PLANTING. THOROUGHLY WATER TWICE TOFACILITATE CONSOLIDATION PRIOR TO PLANTING. DO NOT OVERLYCOMPACT SOIL.7.MULCH TO BE SHREDDED HARDWOOD BARK MULCH (MNDOT 3882 TYPE 6),CONSISTED OF RAW WOOD MATERIAL FROM TIMBER AND BE A PRODUCTOF A MECHANICAL CHIPPER, HAMMER MILL, OR TUB GRINDER. THEMATERIAL SHALL BE SUBSTANTIALLY FREE OF MOLD, DIRT, SAWDUST, ANDFOREIGN MATERIAL AND SHALL NOT BE IN AN ADVANCED STATE OFDECOMPOSITION. THE MATERIAL SHALL NOT CONTAIN CHIPPED UPMANUFACTURED BOARDS OR CHEMICALLY TREATED WOOD, INCLUDING,BUT NOT LIMITED TO, WATER BOARD, PARTICLE BOARD, AND CHROMATEDCOPPER ARSENATE (CCA) OR PENTA TREATED WOOD. THE MATERIALSHALL BE TWICE-GROUND/ SHREDDED, SUCH THAT; NO INDIVIDUAL PIECESHALL EXCEED 2 INCHES IN ANY DIMENSION.8.APPLY FOUR (4) INCH DEPTH OF SHREDDED HARDWOOD BARK MULCH INFOUR (4) FOOT DIAMETER RING AROUND ALL TREES.9.EDGE ALL SHRUB BEDS WITH 3/16" X 5.5" MILL FINISHED ALUMINUM EDGINGWITH STAKES. ALL EDGING TO BE COMMERCIAL GRADE.10.APPLY FOUR (4) INCH DEPTH OF SHREDDED HARDWOOD BARK MULCH INALL SHRUB AREAS. PRIOR TO MULCHING, APPLY PRE-EMERGENTHERBICIDE TO ALL PLANTING BEDS.11.APPLY PRE-EMERGENT TO MULCH IN PLANTING AREAS TO PROHIBIT WEEDGROWTH. APPLICATION RATE TO BE PER MANUFACTURER'SRECOMMENDATIONS. IF WEEDS APPEAR IN TREATED AREAS DURING THEFIRST YEAR, LANDSCAPE CONTRACTOR TO REMOVE ALL WEEDS AT NOADDITIONAL COST.12.APPLY THREE (3) INCH DEPTH OF 2-3 INCH TRAP ROCK MULCH OVER WEEDBARRIER FABRIC IN MAINTENANCE AREAS INDICATED ON PLAN.13.WEED BARRIER FABRIC TO BE BLACK POLYPROPYLENE SHEET 5 OZ/SQ.YD.TENSILE STRENGTH PER ASTM D-4632, PRODUCT BY DEWITT COMPANY ORAPPROVED EQUAL.14.SOD SHOWN ON LANDSCAPE PLAN TO BE INSTALLED BY LANDSCAPECONTRACTOR. SOD TO BE MNDOT 3878.2A, DENSE, AND OF UNIFORMTEXTURE, FREE OF WEEDS AND DISEASE. APPLY MINIMUM SIX (6) INCHESOF SELECT TOPSOIL BORROW AND THOROUGHLY APPLY FERTILIZER TOTOP TWO (2) INCHES BEFORE LAYING SOD. LANDSCAPE CONTRACTOR TOMAINTAIN SODDED AREAS IN HEALTHY CONDITION UNTIL FIRMLY ROOTED.15.LANDSCAPE AREAS IN FRONT OF BUILDINGS AND BOULEVARD AREASSHALL BE IRRIGATED WITH AN UNDERGROUND IRRIGATION SYSTEM. NOWATER IS ALLOWED ON ANY PAVEMENT, PARKING, WALKWAY, ANDBUILDING. THE IRRIGATION CONTRACTOR IS TO DESIGN AND SUBMIT SHOPDRAWING OF IRRIGATION DESIGN AND CALCULATIONS TO LANDSCAPEARCHITECT FOR REVIEW 5 DAYS PRIOR TO PURCHASING ANDINSTALLATION. IRRIGATION DESIGN IS TO MEET ALL CITY AND STATEPLUMBING CODES AND REQUIREMENTS.16.FOLLOW LANDSCAPE DETAILS FOR ALL INSTALLATION, UNLESSOTHERWISE NOTED.17.LANDSCAPE CONTRACTOR SHALL MAINTAIN PLANTS IN HEALTHYCONDITION THROUGHOUT WARRANTY PERIOD. THE WARRANTY PERIOD ISTWO FULL YEARS FROM DATE OF PROVISIONAL ACCEPTANCE UNTIL FINALACCEPTANCE. WARRANTY PERIOD FOR PLANT MATERIAL INSTALLEDAFTER JUNE 1ST SHALL COMMENCE THE FOLLOWING YEAR.STORMWATER SEEDING 4,185 SF.SEE SHEET C-203 FOR SEEDING NOTESSEE SHEET L-101 FOR PLANT SCHEDULETURF AT PROOF OF PARKING 6,280 SF.WATERSHED / CITY COMMENTS 03/08/2024122WATERSHED / CITY COMMENTS 03/08/202411CITY COMMENTS 03/26/20242112