Laserfiche WebLink
UP <br />UP <br />A-31 <br />2 <br />A-301A-30 <br />A-31 <br />2 <br />11 <br />1 <br />R R <br />3 <br />A-40 <br />ELECTRICAL <br />ROOM <br />105 CONFERENCE <br />ROOM <br />103 <br />1 <br />A-42 <br />1 <br />A-41 <br />LAB/ BREAK <br />ROOM <br />108 <br />CONTROL ROOM <br />110 <br />RESTROOM <br />104 <br />STORAGE ROOM <br />106 <br />PERMANGANATE <br />ROOM <br />113 <br />HALLWAY <br />112 <br />MECHANICAL <br />ROOM <br />114 <br />PHOSPHATE <br />ROOM <br />115FLUORIDE ROOM <br />116 <br />P P <br />B B <br />E <br />E <br />4 <br />4 <br />K K <br />6 <br />6 <br />10 <br />10 <br />11 <br />11 <br />12 <br />12 <br />13 <br />13 <br />15 <br />15 <br />HALLWAY <br />102 <br />VESTIBULE <br />101 <br />2 <br />2 <br />5 <br />5 <br />2 <br />A-42 <br />4 <br />A-41 <br />3 <br />A-42 <br />2 <br />A-41 <br />2 <br />A-40 <br />115116 <br />114113108A112A 101A101B110108B <br />22' - 0"13' - 6"17' - 1"16' - 4"16' - 4" <br />1' - 11" <br />14' - 6 3/4"1' - 6 1/4"18' - 3"47' - 8"18' - 4"21' - 5" <br />9"2' - 10" <br />8' - 8"84' - 0"7' - 3"16' - 0"22' - 0"6' - 0"6' - 4" <br />1' - 0" <br />7' - 0"17' - 4"1' - 6"21' - 4"2' - 6"16' - 8"1' - 9 1/4"6' - 0"1' - 6 3/4"6' - 8"23' - 4"4"7' - 8"16' - 0"2' - 0"16' - 0"4' - 0"86' - 5"36' - 3"66' - 0"22' - 2"11' - 6" <br />5' - 0"6' - 0" <br />CHLORINE <br />STORAGE <br />ROOM <br />111 <br />CHLORINE FEED <br />ROOM <br />109 <br />14 <br />14 <br />GARAGE <br />117 <br />PUMP GALLERY <br />119 <br />3 <br />A-41 <br />1 <br />A-40 <br />A A <br />C <br />C <br />D <br />D <br />F <br />F <br />G <br />G <br />H <br />H <br />J J <br />L L <br />M M <br />N N <br />Q Q <br />3 <br />3 <br />3.2 <br />3.2 <br />7 <br />7 <br />8 <br />8 <br />9 <br />9 <br />109111A13' - 7 3/4"15' - 9 1/4"12' - 7"12' - 7"28' - 1"1' - 4"52' - 0"45' - 8"111B <br />6' - 0"STORAGE <br />118 <br />1 <br />A-43 <br />A-17 <br />21' - 8"1 <br />A-52 <br />112B106A118105104103106B3 <br />A-52 <br />A-82 <br />2 <br />A-821 <br />47' - 8" <br />- <br />- <br />117E <br />TW3 <br />10' - 4"12' - 0" <br />8' - 8"5' - 6"1' - 1"909' - 0" <br />T.O. WALL <br />FFE <br />905' - 6" <br />FFE <br />909' - 6" <br />FFE <br />A-32 <br />1 <br />A-325 <br />5.03 <br />48038THOMAS R. STROMSODTWSB PROJECT NO.: <br />SHEETWATER TREATMENT PLANTCITY OF LINO LAKES,MINNESOTA021336-000 <br />SCALE: <br />PLAN BY: <br />DESIGN BY: <br />CHECK BY:REVISIONSNO. DATEDESCRIPTIONSHOWN <br />I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA. LIC. NO:DATE:03/29/2024PERMIT SETAutodesk Docs://021336-000/2323_Lino Lakes WTP_ARCH_v22.rvt4/4/2024 11:42:47 AMMAIN FLOOR <br />PLAN <br />A-13 <br />Designer Checker <br />Designer <br />NORTH3/32" = 1'-0"1 MAIN FLOOR PLAN 3/29/202425