My WebLink
|
Help
|
About
|
Sign Out
Home
Search
09/11/2024 PZ Combined Packet
LinoLakes
>
Advisory Boards & Commissions
>
Planning & Zoning Board
>
Packets
>
2024
>
09/11/2024 PZ Combined Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/6/2024 3:13:12 PM
Creation date
9/6/2024 3:01:11 PM
Metadata
Fields
Template:
P&Z
P&Z Document Type
P&Z Packet
Meeting Date
09/11/2024
P&Z Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
14 <br />RECOMMENDATION <br />Staff recommends approval of the preliminary plat for Slater Addition with the following <br />conditions: <br />1.The new houses on proposed Lots 1 and 2, Block 1, Slater Addition shall connect <br />to municipal watermain and municipal sanitary sewer main. <br />The following items shall be addressed in conjunction with the final plat submittal: <br />1.Comments from City Engineer Memo dated September 4, 2024. <br />2.Comments from Environmental Memo dated August 29, 2024. <br />3.The Site Drainage Narrative and Calculations shall note the name and company <br />that prepared the document. <br />4.All plan sheets shall be signed by a professional. <br />5.Sheet S1, Certificate of Survey: <br />a.Under Area: <br />i.Shouldn’t the lot area be 1.41 acres? <br />ii.This shall be corrected on all applicable plan sheets. <br />b.Water connection to existing house shall be shown. <br />i.This shall be shown on all applicable plan sheets. <br />6.Sheet S2, Preliminary Plat: <br />a.Under Area: <br />i.The lot area shall be corrected. <br />ii.The gross density and net density shall be corrected. <br />b.Water connection to existing house shall be shown. <br />The following items shall be addressed prior to release of the final plat mylars: <br />1.The existing pavers shall be removed. <br />2.The existing fence proposed Lot 2, Block 1, Slater Addition shall be removed. <br />The following items shall be addressed prior to issuing building permits for with Lot 1 or <br />Lot 2, Block 1, Slater Addition: <br />1.Sheet C1.2, Removals Plan, notes the existing septic and existing well to be <br />removed per local and state regulations. <br />a.The developer shall submit to the City the MPCA SSTA Abandonment <br />Reporting Form as proof that the private septic system has been properly <br />removed. <br />b.The developer shall submit to the City the MDH Well and Boring Sealing <br />Record as proof that the private well has been properly capped.
The URL can be used to link to this page
Your browser does not support the video tag.