Laserfiche WebLink
NOTES: <br />1. EXISTING CONDITIONS & TOPOGRAPHIC INFORMATION PROVIDED BY. <br />DESIGN TREE ENGINEERING & LAND SURVEYING <br />120 17TH AVENUE W <br />ALEXANDRIA, MN 56308 <br />2. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING DIMENSIONS AND <br />j D REMOVAL LIMITS PRIOR TO ANY CONSTRUCTION. <br />oP <br />3. THE LOCATIONS AND ELEVATIONS OF THE EXISTING UTILITIES SHOWN <br />HEREIN ARE APPROXIMATE. THEY HAVE BEEN PLOTTED FROM <br />AVAILABLE SURVEYS AND/ OR RECORDS. THE CONTRACTOR IS <br />z <br />OrPC)// / RESPONSIBLE FOR FIELD VERIFYING LOCATION AND ELEVATION TO <br />FRTY�\�/i — \ / / / ENSURE THAT ANY EXISTING UTILITIES (SHOWN OR NOT SHOWN) ARE <br />NOT DAMAGED DURING CONSTRUCTION. <br />4. GOPHER STATE ONE CALL DAMAGE PREVENTION SYSTEM FOR BURIED <br />UTILITIES. 1-800-252-1166. CONTRACTOR SHALL HIRE A PRIVATE <br />UTILITY LOCATOR TO ASSIST WITH PRIVATE UTILITY LOCATES. <br />LEGEND <br />/°) / HYDRANT <br />SANITARY MANHOLE <br />0) <br />��// /'/ / /�� // / <' O GATE VALVE <br />�j)/ POWER POLE <br />o <br />LIGHT POLE <br />46� / o� / CATCH BASIN <br />c// /�/ / / /_—`a <br />SIGN <br />A" <br />DECIDUOUS TREE <br />06-908-- <br />/ CONIFEROUS TREE <br />SANITARY MANHOLE <br />/ SANITARY MANHOLE — — — RIM: 910.86 _ _ SHRUB <br />RIM:908.39 INV W:886.83 <br />/ INV: 889.28 INV NE: 886.83�Q� <br />INV SE: 886.78 Jg/ OH <br />— — <br />-OHE OHE OHE OH H OH � F - - - OH OH�. -0HC 9O OH O H OH€ OH /. Ems.. OHE�-OOHS-�O� �-UJ... L / / PEDESTAL <br />OH <br />y _ <br />---��_--- J —�� C� ;- GUY WIRE <br />BOLLARD <br />77 POWER BOX <br />909— 1 // .� Lza��Jl���lae,.-Nv, O ELECTRIC METER <br />� MONITORING WELL <br />o SANITARY SEWER CLEANOUT <br />— WOOD FENCE <br />CHAINLINK FENCE <br />WIRE FENCE <br />N /� /� / C TCH BASIN X <br />� / // RIM: 911.08 STORM SEWER LINE <br />• / / / INV N: 906.12 <br />� / �/ � INV SW:906.15 <br />SANITARY SEWER LINE <br />WATERMAIN <br />OHS OVERHEAD ELECTRIC <br />_J 1 <br />ua, UNDERGROUND TELEPHONE <br />FO- <br />UNDERGROUND FIBER <br />/ V13 <br />/ Uo= UNDERGROUND ELECTRIC <br />�Alt / GAS UNDERGROUND GAS LINE <br />CONCRETE PAVEMENT <br />V C. JI BITUMINOUS PAVEMENT <br />CATCH BASIN _ <br />RIM: 912.19 AGGREGATE SURFACING <br />INV NE:906.34 �° <br />LANDSCAPING <br />BUILDING <br />\� \� <br />01 <br />/ cz� <br />°� � � <br />� / <br />i / 1 <br />/ I <br />I � <br />I � <br />/ <br />EXISTING <br />BUILDING i <br />z <br />v <br />\ /4. <br />0' 40' 80' <br />DESIGN*TREE <br />engineering + land surveying <br />Corporate Office: <br />120 17th Ave W Alexandria, MN 56308 <br />888-216-1916 <br />AVA <br />P R O P E R T I E S <br />879 Scheffer Avenue <br />St. Paul, MN 55102 <br />Phone: 952-403-9595 <br />I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, <br />OR REPORT WAS PREPARED BY ME OR UNDER MY <br />DIRECT SUPERVISION AND THAT I AM A DULY <br />LICENSED PROFESSIONAL ENGINEER UNDER THE <br />LAWS OF THE STATE OF MINNESOTA. <br />PRINTED NAME: MICHAEL J. GERBER <br />DATE: 09/04/2024 LICENSE #: 56653 <br />LINO LAKES 2.0 <br />LINO LAKES, MN <br />THIS DRAWING AND THE INFORMATION THEREIN IS <br />THE PROPERTY OF DESIGN TREE ENGINEERING INC. <br />USE BY THE HOLDER OR DISCLOSURE TO OTHERS <br />WITHOUT THE PERMISSION OF DESIGN TREE <br />ENGINEERING INC. IS PROHIBITED. IT CONTAINS <br />PROPRIETARY AND CONFIDENTIAL INFORMATION OF <br />DESIGN TREE ENGINEERING INC. REPRODUCTION OF <br />THE MATERIAL HEREIN WITHOUT WRITTEN <br />ERMISSION OF DESIGN TREE ENGINEERING INC. <br />VIOLATES THE COPYRIGHT LAWS OF THE UNITED <br />STATES AND WILL SUBJECT THE VIOLATORS TO <br />LEGAL PROSECUTION. <br />COPYRIGHT @ 2024 BY DESIGN TREE ENGINEERING <br />DRAWN BY: RJK <br />CHECKED BY: JEA <br />PROJECT NO.: 10923008 <br />NO. DATE DESCRIPTION <br />EXISTING <br />CONDITIONS <br />DRAWING NO. <br />C101 <br />