01/08/2025 PZ Combined Packet
LinoLakes
>
Advisory Boards & Commissions
>
Planning & Zoning Board
>
Packets
>
2025
>
01/08/2025 PZ Combined Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2025 2:42:20 PM
Creation date
1/3/2025 2:40:37 PM
Metadata
Fields
Template:
P&Z
P&Z Document Type
P&Z Packet
Meeting Date
01/08/2025
P&Z Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5 <br />Per City Code Section 1007.052(6): <br /> <br />• Auto repair requires 4 spaces plus 2 spaces per service bay. <br />o Three (3) service bays are proposed which requires 10 parking spaces <br /> 4 + (2x3) = 10 <br />• Office space requires 1 space for each 200 square feet of floor area. <br />o The site plan indicates 1,720sf of office which requires 9 parking spaces <br /> 1720/200 = 8.6 = 9 <br />• Total number of required parking spaces is 19. <br /> <br />The site plan provides 7 parking stalls with 1 being ADA compliant as well as 12 proof of parking <br />spaces within the outdoor storage area for a total of 19. Per City Code Section 1007.052(7)(b): <br />In no case shall the amount of off-street parking provided be less than one-half of the amount <br />of parking required by ordinance. Per City Code Section 1007.141(9)(h): The storage area does <br />not take up parking space or loading space as required for conformity to this chapter and is not <br />located in the front yard. <br /> <br />Parking requirements are not met. Parking requirements shall be met without the need for <br />deferred parking and cannot be located within outdoor storage area. <br /> <br />Grading Plan and Stormwater Management <br /> <br />Per City Engineer Memo dated December 20, 2024, stormwater management for the 416 Lilac <br />Street site consists of constructing a new sedimentation basin on the northwest corner of the <br />site. <br /> <br />Pre- and Post- Development Discharge Rates (cfs) <br />Condition 2-Year 10-Year 100-Year 10-Day <br />Snowmelt <br />Existing 3.96 6.14 10.23 Not required <br />Proposed 3.14 5.12 9.56 Not required <br /> <br />The stormwater management plan does not meet City requirements and shall be revised. <br /> <br />Public Utilities <br /> <br />The existing building is municipally served by a 12” DIP watermain and a 8” PVC sanitary sewer <br />located along Lilac Street. <br /> <br />Screening, Landscaping, Buffer Yards and Tree Preservation <br />