My WebLink
|
Help
|
About
|
Sign Out
Home
Search
10/08/2025 PZ Combined Packet
LinoLakes
>
Advisory Boards & Commissions
>
Planning & Zoning Board
>
Packets
>
2025
>
10/08/2025 PZ Combined Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/3/2025 10:11:49 AM
Creation date
10/3/2025 10:11:45 AM
Metadata
Fields
Template:
P&Z
P&Z Document Type
P&Z Packet
Meeting Date
10/08/2025
P&Z Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The building height is 22ft which is less than that maximum 45 ft allowed. <br />An interior mechanical room is proposed. Any exterior mechanical equipment shall be <br />screened per ordinance. <br />Grading Plan and Stormwater Management <br />Per the City Engineer Memo dated October 1, 2025: <br /> <br />Stormwater management for 7920 Lake Drive site consists of constructing infiltration <br />basins on the east and west sides of the site. <br /> <br />Pre- and Post- Development Discharge Rates (cfs) <br />Condition2-Year 10-Year 100-Year 10-Day Snowmelt <br />Existing* 0.84 1.81 5.21 Not required <br />Proposed 0.78 1.55 5.43 Not required <br />Additional comments/revisions are noted in the attached City Engineer memo. <br />Public Utilities <br />The commercial buildingwill be municipally served by an 8” sanitary sewer main and <br />12” watermain along Kelly Street. <br />Tree Preservation, Mitigation Standards and Landscaping <br />Per the September 24, 2025 Environmental Board staff report: <br />A tree preservation plan was required for this project. There are 17 existing onsite trees, <br />as part of the project 4 will be removed. The 4 trees to be removed are within the Basic <br />Use Area and do not require replacement. <br />Foundation landscaping requirement are 2 large trees + 4 large shrubs per 100lf of <br />building facing public roads. The site has 403 lf of foundation frontage requiring 8 trees <br />and 24 shrubs. <br />The plans show 25 shrubs meeting the requirements but only 2 large trees (4 medium <br />trees) being proposed. Based on the design of the building with office frontage and <br />doors to the sidewalk, additional tree planting is not feasible. City Code section <br />1007.049 4(d) states the city may allow flexible planting locations where service areas or <br />5 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.