Laserfiche WebLink
d) provision of economic benefits to the City that would not occur without the <br />project <br />Development in areas guided Mixed Use must comply with the following <br />performance standards: <br />1. The land use and site design must be sensitive to the surrounding land uses <br />in the area, including but not limited to building height, exterior composition, <br />landscaping, and site access. <br />2. The road network within new development shall promote the safe and <br />convenient traffic movement. The project design must incorporate access <br />management design elements for access to arterial and collector roadways. <br />3. Municipal water and sanitary sewer service must be available. <br />4. All development shall address environmental concerns with regard to site <br />planning, landscaping, impervious surfacing, open space, and storm water <br />management. Stormwater management must incorporate methods to protect <br />and improve water quality such as infiltration, buffering of water bodies, and <br />other natural methods whenever feasible. <br />5. Commercial site designs shall emphasize pedestrian accessibility, <br />connections to residential neighborhoods, shared parking, and green space <br />to create a customer friendly environment and promote a high level of <br />interaction among local businesses and between businesses and residents. <br />6. Architectural and site standards shall be applied to establish aesthetically <br />pleasing, high quality buildings and streetscapes. <br />Village of Hardwood Creek <br />The Village of Hardwood Creek development area is located 1/4 mile north of <br />Main St., between I -35E and CSAH 21 (20th Ave.). This 360 -acre development <br />site is to be developed with commercial and residential uses. The concept plan <br />for the development includes 500,000 to 600,000 square feet of commercial <br />space on 55 to 70 acres of the site. A variety of single family and multi - family <br />residential development will include approximately 1200 to 1250 dwelling units. <br />The net residential density is to be approximately 4.5 units per acre, when <br />including all and not within the commercial area. While these are the <br />approximate use parameters, the specifics of the development are to be part of a <br />master plan using a planned unit development approach. <br />In the northeast corner of the site, a triangle is formed by I -35E, a pipeline, and <br />the property boundary. This area could be designed to accommodate an office <br />campus type use, which could be a suitable land use along the freeway. This <br />would reduce the amount of residential land noted above. Such flexibility is <br />appropriate for the area. <br />