My WebLink
|
Help
|
About
|
Sign Out
Home
Search
02/12/2014 P&Z Packet
LinoLakes
>
Advisory Boards & Commissions
>
Planning & Zoning Board
>
Packets
>
2014
>
02/12/2014 P&Z Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2022 12:16:35 PM
Creation date
2/7/2014 2:57:11 PM
Metadata
Fields
Template:
P&Z
P&Z Document Type
P&Z Packet
Meeting Date
02/12/2014
P&Z Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ramA <br />iiY SB <br />� Assac� engineering • planning • environmental • construction <br />Memorandum <br />To: Katie Larsen, City Planner <br />From: Jason C. Wedel, P.E. <br />Date: February 3, 2014 <br />Re: Talan Ridge Preliminary Plat Review <br />WSB Project No. 2029-690 <br />701 Xenia Avenue South <br />Suite 300 <br />Minneapolis, MN 55416 <br />Tel: 763-541-4800 <br />Fax: 763-541-1700 <br />The Talan Ridge Preliminary Plat documents received on January 13, 2014 included the <br />following: <br />1. Certificate of Survey <br />2. Resources Inventory <br />3. Preliminary Plat <br />4. Preliminary Grading, Drainage & Erosion Control Plan <br />5. Preliminary Utility Plan <br />6. Landscape Plan <br />7. Tree Preservation & Mitigation Plan <br />8. Drainage Calculation (dated 1/7/14) <br />General Comments: <br />i. Mr. Mattke needs to revise his signature block on the plans to include PE and not LS as <br />currently shown. <br />2. Since there isn't any in place storm water treatment for this area, the Developer will need to <br />create an infiltration depression capable of storing and infiltrating the additional runoff from <br />a 100-year storm event. The storage amount is the difference between the existing conditions <br />and the proposed condition which per the drainage calculations provided is .06 acre feet of <br />storage. I would recommend grading the infiltration depression adjacent to the existing <br />wetland on the south end of the property. A drainage and utility easement over this area will <br />be required. <br />3. Additional information will need to be provided to confirm the ground water elevation for <br />this area. This information is needed to verify that the low floor elevations meet City <br />requirements and that there is enough separation between the infiltration basin and the <br />existing ground water. <br />4. The grading plans need to be revised so that none of the drainage is being directed onto the <br />adjacent properties to the east or west. This will require side yard swales to be graded along <br />the lot lines. Likewise, the interior side lot lines also need to include drainage swales <br />directing runoff to the north or south. <br />St. Cloud • Minneapolis • St. Paul <br />Equal Opportunity Employer <br />wsbeng.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.