Laserfiche WebLink
NEW FACILITY FOR: <br />MIDSTATES TIRE AND TOOL, INC. <br />LINO LAKES <br />SHEET INDEX <br />SHEET SHEET TITLE <br />COVER <br />C1.0 GRADING /DRAINAGE /EROSION CONTROL PLAN <br />C1.1 UTILITY PLAN <br />C2.0 DETAILS <br />S1.0 FOUNDATION PLAN (UPPER) <br />S1.1 FOUNDATION PLAN (LOWER) AND PIER DETAILS <br />S2.0 PIER DETAILS AND FOUNDATION DETAILS <br />S2.1 FOUNDATION DETAILS <br />A1.0 FIRST FLOOR PLAN (UPPER) <br />A1.1 FIRST FLOOR PLAN (LOWER), MEZZANINE PLAN, AND REFLECTED CEILING PLANS <br />A2.0 ELEVATIONS <br />A3.0 SECTIONS <br />A3.1 SECTIONS <br />A3.2 SECTIONS <br />A4.0 SCHEDULES AND DETAILS <br />A4.1 DETAILS <br />C51 FORMAT DRAWING KEY <br />SHEET TYPE <br />SERIES <br />PLANS <br />ELEVATIONS <br />SECTIONS <br />DETAILS /SCHEDULES <br />2 <br />4 <br />SYMBOLS & KEYS <br />Ci - - - -- COLUMN GRID <br />DETAIL <br />SCALE: W — 7' —o <br />�XXXX <br />ELEV: 003 —XX <br />IECTICO1 .001 <br />BUILDING SECTION <br />REFERENCE <br />SECTION MIL DE FOUND <br />CCM 1.1101 <br />DETAIL IDENTFICATON <br />FOUND SKET SUN. <br />DUAL 1.001 <br />SKr NM. ON 10101 <br />SEUL IV <br />PLAN DETAIL <br />REFERENCE <br />111 DET/11. <br />ELEVATION MARKER <br />REVISION <br />DOOR IDENTIFICATION <br />WINDOW IDENTIFICATION <br />ROOM IDENTIFICATION <br />KEY NOTE IDENTIFICATION <br />NEW MASONRY WALL <br />NEW STUD WALL <br />EXISTING WALL TO BE <br />REMOVED <br />EXISTING WALL TO <br />RE/MIN <br />PROJECT INFORMATION <br />MINNESOTA <br />BUILDING CODE: IBC 2000 <br />BUILDING SIZE <br />FIRST FLOOR AREA (50. R.1: <br />MEZZANINE AREA (55. FT.): <br />NUMBER OF STORIES'. <br />EAVE HEIGHT. <br />MAXIMUM OVERALL HEIGHT: <br />CONSTRUCTION CLASSIFICATION <br />30,870 <br />1,840 <br />15, -0' <br />22' -0' <br />TYPE 118 <br />OCCUPANCY <br />5 -I <br />LOCATION MAP <br />DESIGN LOADS, PER IBC 2000, CHAPTER 16 <br />Pg = <br />BASIC WIND SPEED - <br />WIND EXPOSURE = <br />SEISMIC CATEGORY <br />SOIL BEARING PRESSURE _ <br />50 PSF <br />90 MPH <br />A <br />2000 PSF PRESUMED <br />FIRE PROTECTION SYSTEMS <br />AUTOMATIC FIRE SPRINKLER SYSTEM - REQUIRED <br />STANDPIPE SYSTEMS - NOT REQUIRED SEE IBC 905 <br />FIRE ALARM SYSTEM - NOT REQUIRED SEE IBC 907 <br />SMOKE DETECTORS - INSTALL PER APPLICABLE CODES <br />EXIT SONS - PROVIDE EXIT SIGNS PER IBC 1003.2,10 <br />FIRE EXTINGUISHERS - INSTALL PER WC AND APPLICABLE LOCAL CODES <br />APOLLO BUSINESS PAR <br />UNO LAKES. MN <br />GENERAL NOTES <br />THESE PLANS ARE PRESENTED TO LEAD A HIGH DUALITY DESIGN /BUILD TEAM, <br />EACH CONTRACTOR AND SUBCONTRACTOR 15 RESPONSIBLE TO PROVIDE EXCELLENT <br />BUILDING MATERIALS AND CRAFTSMANSHIP WHICH WE CAN ALL BE PROUD OF. WE <br />ENCOURAGE YOU TO PROVIDE EXPERTISE IN YOUR CHOSEN FIELD AND TO BRING <br />IDEAS AND CONCERNS TO THE ATTENTI05 OF THE GENERAL CONTRACTOR. <br />THESE DRAWINGS COVER STRUCTURAL AND GENERAL CONSTRUCTION ONLY. ALL <br />WORK SHALL CONFORM TO STANDARD PRACTICES AND APPUCABLE LAWS, <br />WHETHER THEY ARE SPECIFICALLY STATED IN THESE PLANS OR NOT. <br />EACH CONTRACTOR SHALL: <br />— VISR THE SITE TO VERIFY EXISTING CONDITIONS. ACCESS, ETC. PRIOR TO <br />BIDDING <br />— MAINTAIN A CLEAN J08 SITE AT ALL nuts. <br />— OBTAIN AND PAY FOR PERMITS, LICENSES, FEES, ETC. AS MAY BE REQUIRED <br />FOR COMPLETION OF HIS OWN PORTION OF THE PROJECT. <br />— FIELD VERIFY DIMENSIONS. <br />— REPORT ANY DISCREPANCY NOTED BETWEEN THESE PLANS AND APPLICABLE <br />CODES TO THE GENERAL CONTRACTOR <br />— PROVIDE All BARRIERS. FENCES. SAFETY EQUIPMENT AND PRECAUTIONS <br />REQUIRED BY APPLICABLE LAWS AND STANDARD PRACTICES. <br />ALL MATERIALS SHALL BE INSTALLED PER MANUFACTURERS REQUIREMENTS AND <br />RECOMMENDATIONS. <br />ANY HAZARDOUS MATERIALS ENCOUNTERED DURING DEMOLITION, REMODELING, OR <br />EXCAVATION 51uL1 BE REMOVED AND /0R CONTAINED IN ACCORDANCE WITH <br />GOVERNING LOCAL, STATE, AND FEDERAL REGULATIONS. <br />THIS DESIGN, THESE DRAWING, AND INCLUDED DETAILS ARE THE COPYRIGHTED <br />PROPERTY OF INTEGRITY ENGINEERING & DESIGN, LLC. NO PART SHALL BE <br />COPIED. DISTRIBUTED, OR MADE AVAILABLE TO ANYONE WITHOUT THE EXPRESS <br />WRITTEN CONSENT OF INTEGRITY ENGINEERING & DESIGN, LLC. <br />QUICK SPEC <br />TO MAKE THIS PLAN MORE CONTRACTOR FRIENDLY, WE HAVE PREPARED IT 31111 <br />OUR TACK SPEQ SYSTEM. <br />THE WRITTEN SPEC 15 GENERAL AND DOES NOT GO INTO DEPTH TO REITERATE <br />STANDARD PRACTICES OR APPUCABIE LAWS. IT IS WRITTEN IN AN EASY TO READ <br />FORMAT. THE SPECIFICATIONS SPLIT INTO APPROPRIATE SECTIONS AND LISTED <br />ON THE PLAN WHERE IT 15 NEEDED. YOU WILL FIND THESE SECTIONS QUICKLY BY <br />THE SHADOW BOX AROUND IT (SIMILAR TO THIS ONE). <br />SPECIFIC CASES THAT CANNOT BE DESCRIBED IN A GENERAL SPEC ARE NOTED <br />ON THE PLANS. IF THERE IS A DISCREPANCY BETWEEN THE PLAN AN0 THE <br />GENERAL SPEC. THE PLAN NOTES WILL SUPERSEDE THE GENERAL SPEC. <br />CALL 3 WORK DAYS <br />BEFORE YOU DIG <br />DIGGERS ® HOTLIn <br />(800) 242-8511 <br />FAX ( 3B &3800 <br />WEBSITE.1ww.ramerraTotlioe.com <br />A DESIGN / BUILD PROJECT BY: <br />Keller <br />TM PLANNERS I ARCHITECTS I BUILDERS <br />DESIGN / BUILD <br />GENERAL CONTRACTORS <br />920 - 766 -5795 WATS:1- 800 - 236 -2534 <br />P.O. BOX 620 N216 STATE ROAD "55" <br />KAUKAUNA, WISCONSIN 54130 -0620 <br />Keller <br />PLANNERS 1 ARCHITECTS !BUILDERS <br />MOM <br />• <br />1.011E mums>. <br />rAY 2111.47.17.110 <br />Z <br />• <br />"COPYRIGHT NOTICE" <br />11 .O.W.. comp one <br />FeP.NN.a PeP."Y ., I¢uEN. INC <br />="...‘ """ •KN. <br />"NOT FOR CONSTRUCTION" <br />Inlonno. about 0. own mow. <br />%ran a <br />nw.1 w "D1R1wt�""h owe <br />• <br />O <br />0 <br />■ <br />z <br />W <br />H <br />a <br />6-0 <br />MINNESOTA <br />LINO LAKES, <br />REVISIONS <br />. <br />PROJECT MANAGER: <br />ARCHITECT: <br />DRAWN BY: <br />EXPEDITOR: <br />M. CA5HMAN <br />5. KLESSIG <br />G. HOHN <br />SUPERVISOR: <br />PRELIMINARY N0: <br />CONTRACT N0: <br />LED. / <br />05056 <br />ISSUED FOR CONSTRUCTION: <br />01/05/06 <br />SHEET: <br />