Laserfiche WebLink
• <br />• <br />• <br />Main Street Village <br />Drainage Review <br />City of Lino Lakes, Minnesota <br />Page 3 January 2, 2008 <br />17. Include a detail of the Enekamat overflow for biofiltration basin 9 on the plan. <br />18. It is highly recommended that the curb cut openings be a minimum of five feet. Past experience has <br />shown that water flowing in the curb line may bypass a curb cut opening that is less than five feet. <br />19. Include a note on the plan stating that the sod filter strip at each curb cut needs to be lower than the <br />back of the curb cut. <br />Additional Comments (01/02/08) <br />20. Stormwater management areas within the AUAR are required have side slopes that are less <br />than or equal to 6:1. Revise the side slopes on the plan and section view of the wetland <br />mitigation area on Sheet 10 to a maximum of 6:1. <br />21. The AUAR indicates that drain tile exists in the vicinity of the site. Confirm that drain tile <br />does not exist at the proposed project location. <br />