My WebLink
|
Help
|
About
|
Sign Out
Home
Search
04/11/2001 P&Z Packet
LinoLakes
>
Advisory Boards & Commissions
>
Planning & Zoning Board
>
Packets
>
2001
>
04/11/2001 P&Z Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/18/2014 4:48:26 PM
Creation date
5/30/2014 1:25:03 PM
Metadata
Fields
Template:
P&Z
P&Z Document Type
P&Z Packet
Meeting Date
04/11/2001
P&Z Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TKDA <br />• ENGINEERS • ARCHITECTS • PLANNERS <br />• <br />TOLTZ, KING, DUVALL, ANDERSON <br />AND ASSOCIATES, INCORPORATED <br />MEMORANDUM <br />To: <br />John Powell Reference: Spirit Hills <br />1500 PIPER JAFFRAY PLAZA <br />444 CEDAR STREET <br />SAINT PAUL, MINNESOTA 55101 -2140 <br />PHONE: 651 /292 -4400 FAX: 651/292 -0083 <br />Copies To: Lino Lakes, Minnesota <br />From: Jason Wedel <br />Date: April 4, 2001 <br />Commission No. 11985 -012 <br />I have reviewed the preliminary plat and plans for Spirit Hills received on March 13, 2001. I <br />have the following comments: <br />Plat <br />1. The drainage and utility easement between Lots 2 & 3, Lots 16 & 17, and Lots 24 & 25, <br />Block 1, must be 10 feet on either side of the property line to accommodate the proposed <br />storm sewer. <br />Grading Plan <br />1. The existing contours do not tie into the proposed contours around the basin at the north <br />end of the project. <br />2. The emergency overflow locations and elevations must be labeled. <br />3. The normal water elevations and high water elevations must be shown for all of the <br />basins. <br />4. Soil borings must be submitted for the site. <br />Utility Plan <br />1. The second townhouse unit south of Sioux Lane, on the east edge of the proposed <br />subdivision, has inadequate fire protection. <br />2. A hydrant must be added at the end of the watermain stub, located south of Sioux Lane, <br />for flushing purposes. This will also correct the previous comment. <br />• 3. The 10 -inch PVC sanitary sewer is not justified by the proposed flows. The sanitary <br />sewer should be 8 inch. <br />An Equal Opportunity Employer <br />
The URL can be used to link to this page
Your browser does not support the video tag.