Laserfiche WebLink
Adequate capacity exists in the sanitary sewer system to service the proposed <br />development. In addition, the Black Duck Lift Station, which services the area, is <br />scheduled for replacement in 2003. <br />Drainage and Utility Easements. Drainage and Utility easements are proposed being five <br />feet in width at adjoining lot lines, and 10 feet in width at adjoining street lines and rear <br />lot lines as required. Drainage and Utility easements covering the 100 year High Water <br />Level and those covering underground storm sewers are subject to review and approval <br />by the City Engineer. Easements should be provided to access all pond and wetland <br />areas. Specifically, easements should be provided to access Outlot F and cover the <br />emergency overflow on Lots 6, 9, and 10, Block 8. <br />Parkland Dedication. The Park Board discussed the proposed subdivision at its February <br />4, 2002 meeting. The board is recommending 100% cash payment in lieu of parkland <br />dedication. As explained in the Public Services Director's February 5, 2002 memo <br />(attached), the proposed development lies outside the planning limits of the <br />Comprehensive Park and Trail System Plan. The Park Board looked at several <br />alternatives and recommended the payment in lieu as the preferred option. <br />Floodplain. Portions of the site lie within a Flood Plain Zone A. Zone A represents areas <br />of 100 year flood where base flood elevations have not been determined. The City's <br />Floodplain Management Ordinance requires that principal structures be located no lower <br />than one foot above the regulatory flood protection elevation. The City's Subdivision <br />Ordinance requires that proposed basements be four (4) feet above the water table <br />(normal water level) and two (2) feet above the design flood levels of ponding areas. <br />The submitted grading plan identifies proposed 100 year High Water Level elevations. <br />Conformance to the requirements cannot be determined for Lots 23 through 27, Block 8 <br />due to lack of documentation on the normal and high water levels of wetlands No. 12 and <br />No. 13. The applicant should submit this documentation. All other lots are in <br />conformance. <br />The proposal is subject to the review and approval of the City Engineer and Rice Creek <br />Watershed District. If the proposed subdivision is approved, the Developer will be <br />required to make application to FEMA for a Letter of Map Amendment (LOMA) or <br />Letter of Map Revision (LOMR) to revise the existing Flood Plain maps consistent with <br />the proposed grading. <br />Wetlands. The project site contains 19.39 acres of wetland. 2.06 acres of wetland are <br />proposed to be impacted by the site development. The wetland mitigation will take place <br />on -site, by creating two new wetlands and three water quality ponds, which will have a <br />total area of 2.51 acres and 3.27 acres, respectively. A portion (.20 acres) -of one of the <br />existing wetland areas will be converted from a Type 2 wet meadow to a Type 3 s allow <br />marsh wetland to help facilitate site drainage. <br />Stoneybrook Page 5 <br />