Laserfiche WebLink
Lake Main Motor Fuel CUP <br /> Page 6 <br /> The City should consider potential impacts of the bright lighting below <br /> a canopy and the proximity to residential properties. Submitted <br /> information states that the store business hours will be 5:00 a.m. to <br /> 11:00 p.m. Outside of these hours, the fuel pumps will operate but <br /> canopy lighting will be reduced to a night level which will be about 10% <br /> of illumination. This will provide enough light to dispense fuel. <br /> (Note: A compact disc with electronic copies of the submittals includes <br /> a different lighting fixture: A Lithonia KACM surface mount model. It is <br /> not clear what this is intended for, but a surface mounted fixture is not <br /> acceptable.) <br /> 5) The architectural design, colors, and character of the canopy shall be consistent with <br /> the principal building on the site. <br /> • We received a new elevation for a canopy. The canopy material is <br /> yellow metal. The supporting columns will be stucco with brick bases. <br /> The color and the brick will be consistent with the principal building. <br /> 6) Signage may be allowed on a detached canopy in lieu of wall signage on the <br /> principal structure, provided that: <br /> a) The individual canopy sign does not exceed more than twenty(20)percent of the <br /> canopy facade facing a public right-of-way. <br /> • There currently is no signage on the convenience store part of the <br /> building because the store space has been vacant. Canopy signage <br /> must be included in the total amount of wall signage allowed. The <br /> canopy design includes only a logo of approximately 6 sf on each face. <br /> Future signage will be reviewed through sign permits. <br /> 7) Canopy posts/sign posts shall not obstruct traffic or the safe operation of the gas <br /> pumps. <br /> • The canopy posts are not problems, the canopy location overall is an <br /> issue. <br /> d. Pump Islands. Pump islands shall comply with the following performance standards: <br /> 1) Pump islands shall be elevated six (6) inches above the traveled surface of the site. <br /> 2) All pump islands shall be set at least thirty(30) feet back from any property line. <br /> Additionally, the setback between the pump islands curb face must be at least <br /> twenty-four(24) feet. <br /> • The pump islands are properly elevated and set back both from each <br /> other and from property lines. <br /> e. Dust Control and Drainage. The entire site other than taken up by a building, <br /> structure, or plantings shall be surfaced with asphalt, concrete, cobblestone, or paving <br /> brick. Plans for surfacing and drainage shall be subject to approval of the City Engineer. <br /> Drainage from all fueling areas shall be directed to an oil/grit separator. Minimum design <br /> standards for the oil/grit separator shall include the following: <br />