Laserfiche WebLink
• Recommend removal of infiltration pond rock bottoms <br /> • <br /> • Recommend changing the clay lined pretreatment ponds to a storm chamber type of oil <br /> grit separator large enough to accommodate the water volumes generated on the site and <br /> include the 800 gal oil capture capacity as required by city code. <br /> • Recommend soli borings to verify that all infiltration areas including swales are not in the <br /> SoA soil type. <br /> • Recommend that the site meet the .5 inch infiltration requirement to the extent possible, <br /> and a variance given from RCWD to the project for remainder of this requirement not <br /> attainable. <br /> • Recommend that as a part of their MS4 requirements that maintenance plan and yearly <br /> inspection submittal to the city be submitted for all storm water features on the site. <br /> • Recommend that the second well shown registered to the original owner in the county <br /> well point index be located and sealed if it can be located. This well point is located on <br /> the eastern property line. <br />