Laserfiche WebLink
SADDLE CLUB P.U.D. <br />TITLE SHEET, NOTES & LEGEND <br />LINO LAKES, MN <br />CURB & BITUMINOUS NOTES <br />REMOVAL AND DISPOSAL OF EXISTING STREET MATERIALS AS REQUIRED FOR <br />CONSTRUCTION IS CONSIDERED INCIDENTAL. <br />SAW -CUT EXISTING BITUMINOUS AND CONCRETE CURB TO PROVIDE BUTT -JOINT. <br />RESTORE DISTURBED STREET TO EXISTING OR BETTER SECTION. <br />BACKFILLING OF CURB IS INCIDENTAL TO CURB INSTALLATION. <br />FOUR INCHES OF CLASS 5 UNDER CURB IS INCIDENTAL TO CURB INSTALLATION. <br />CURB ENDS SHALL TERMINATE IN A THREE-FOOT BEAVER TAIL. <br />STORM SEWER NOTES <br />FIELD VERIFY SIZE, ELEVATION, AND LOCATION OF EXISTING STORM SEWER AND <br />NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO ANY INSTALLATIONS. <br />WHEN CALLED OUT AS PIPE, STORM SEWER SHALL BE REINFORCED CONCRETE <br />PIPE (RCP) ANSI C76 WITH R-4 GASKETS OR, IF ALLOWED BY CITY, HDPE PIPE <br />MAY BE USED. (SEE PLAN FOR LOCATIONS WHERE RCP IS REQUIRED.) HDPE <br />PIPE SHALL MEET THE REQUIREMENTS OF AASHTO M294, TYPE S WITH <br />WATERTIGHT CONNECTIONS. USE SAND/GRANULAR MATERIAL FOR BACKFILLING <br />AND COMPACTION OF HDPE/PVC PIPE IN ACCORDANCE WITH THE <br />REQUIREMENTS OF ASTM 2321. <br />STORM SEWER LENGTHS INCLUDE THE LAYING LENGTH OF THE FLARED -END <br />SECTION. LAYING LENGTH OF APRON TO BE DEDUCTED FROM PAYMENT LENGTH <br />OF PIPE. <br />STORM SEWER PIPES TO BE JOINED TO THE CATCH BASIN MANHOLES W/ <br />APPROVED RESILIENT RUBBER JOINTS TO MAKE THEM GASTIGHT OR <br />WATERTIGHT. CEMENT MORTAR JOINTS ARE PERMITTED ONLY FOR REPAIRS <br />AND CONNECTIONS OF EXISTING LINES CONSTRUCTED WITH SUCH JOINTS. <br />SHEET INDEX <br />CO <br />C1-1 <br />C1-2 <br />C2 <br />C3.1 <br />C3.2 <br />C3.3 <br />C4-1 <br />C4-2 <br />TITLE SHEET, NOTES & LEGEND <br />GRADING, DRAINAGE & EROSION CONTROL PLAN <br />GRADING, DRAINAGE & EROSION CONTROL PLAN <br />PHASING PLAN <br />DETAILS <br />DETAILS <br />DETAILS <br />STORMWATER POLLUTION PREVENTION PLAN <br />STORMWATER POLLUTION PREVENTION PLAN <br />STREET & STORM SEWER PLAN/PROFILE <br />C5.1 <br />C5.2 <br />C5.3 <br />C5.4 <br />PHEASANT RUN S - STA 0+00 TO 8+50 <br />PHEASANT RUN S - STA 8+50 TO 17+32.96 <br />FOX ROAD - STA 0+00 TO 11+56.62 <br />SADDLE CLUB COURT - STA 0+00 TO 2+7.70 <br />BLACK BERRY COURT - STA 0+00 TO 5+4.55 <br />SANITARY SEWER & WATER PLAN/PROFILES <br />C6.1 BIRCH ST & OLD BIRCH ST - STA -15+01 TO -6+00 <br />C6.2 OLD BIRCH ST - STA -6+00 TO 0+00 <br />C6.3 PHEASANT RUN S - STA 0+00 TO 9+00 <br />C6.4 PHEASANT RUN S - STA 9+00 TO 17+32.96 <br />C6.5 FOX ROAD - STA 0+00 TO 11+56.62 <br />C6.6 SADDLE CLUB COURT - STA 0+00 TO 2+7.70 <br />BLACK BERRY COURT - STA 0+00 TO 5+4.55 <br />.. <br />• <br />erzcy4 STREET <br />GENERAL NOTES <br />THE INFORMATION SHOWN ON THESE DRAWINGS CONCERNING TYPE AND <br />LOCATION OF EXISTING UTILITIES IS NOT GUARANTEED TO BE ACCURATE OR ALL <br />INCLUSIVE. THE CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN <br />DETERMINATION AS TO TYPE AND LOCATION OF UTILITIES AS NECESSARY TO <br />AVOID DAMAGE TO THESE UTILITIES. <br />CALL "811" FOR EXISTING UTILITIES LOCATIONS PRIOR TO ANY EXCAVATIONS. <br />INSTALLATIONS SHALL CONFORM TO THE CITY STANDARD SPECIFICATIONS AND <br />DETAIL PLATES. <br />THE CONTRACTOR SHALL NOTIFY CITY PUBLIC WORKS DEPARTMENT A MINIMUM <br />OF 24 HOURS PRIOR TO THE INTERRUPTION OF ANY SEWER OR WATER <br />SERVICES TO EXISTING HOMES OR BUSINESSES. <br />STORAGE OF MATERIALS OR EQUIPMENT SHALL NOT BE ALLOWED ON PUBLIC <br />STREETS OR WITHIN PUBLIC RIGHT-OF-WAY. <br />NOTIFY CITY A MINIMUM OF 48 HOURS PRIOR TO THE COMMENCEMENT OF <br />CONSTRUCTION. <br />VICINITY MAP <br />© Country <br />5 Lakes Park <br />3 <br />vows 4, <br />CN" <br />Reshatrou Lake <br />347 <br />'Birch Lc <br />/wood in <br />Birch 5t ad 8irrh SI <br />g <br />n Ln <br />Birch S <br />S <br />White Od <br />Way Or <br />I.T.S. <br />LEGEND <br />OH W <br />TEL <br />CBL <br />4 <br />3Yo <br />930 <br />928 <br />x 920.99 <br />cC <br />x <br />wet <br />TH#2 <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />OVERHEAD ELECTRIC <br />UNDERGROUND TELEPHONE <br />UNDERGROUND CABLE <br />TELEPHONE PEDESTAL <br />ELECTRICAL PEDESTAL <br />CABLE PEDESTAL <br />UTILITY POLE <br />LIGHT POLE <br />STORM SEWER <br />WATER MAIN <br />SANITARY SEWER <br />EXISTING STORM MANHOLE <br />EXISTING FLARED -END SECTION <br />EXISTING GATE VALVE <br />EXISTING HYDRANT <br />EXISTING SANITARY SEWER MANHOLE <br />EXISTING CONTOUR <br />EXISTING SPOT ELEVATION <br />NAVD88 DATUM <br />EXISTING FENCE <br />DELINEATED WETLAND EDGE <br />DELINEATION BY "EARTH SCIENCE <br />ASSOCIATES, INC." ON 10-29-12 <br />TEST PITS/BORINGS <br />PERFORMED BY "NORTHERN <br />TECHNOLOGIES, INC." <br />EXISTING WELL AND SEPTIC SYSTEM TO BE FIELD <br />LOCATED. WELL TO BE CAPPED PER ALL LOCAL AND <br />STATE REQUIREMENTS. SEPTIC SYSTEM TO BE <br />REMOVED PER ALL LOCAL AND STATE REQUIREMENTS. <br />-(«<- 0 <br />A <br />-928- <br />-930- <br />X 920.60 <br />s <br />• ss • <br />♦•••••♦ <br />t <br />+ t + <br />ttttt <br />0 <br />PROPOSED WATER PIPE <br />PROPOSED SANITARY SEWER PIPE <br />PROPOSED STORM SEWER PIPE <br />PROPOSED DRAINTILE AND CLEAN-OUT <br />PROPOSED STORM MANHOLE <br />PROPOSED CATCH BASIN <br />PROPOSED FLARED -END SECTION <br />PROPOSED GATE VALVE <br />PROPOSED HYDRANT <br />PROPOSED SANITARY SEWER MANHOLE <br />PROPOSED CONTOUR <br />PROPOSED SPOT ELEVATION <br />NAVD88 DATUM <br />(GUTTERLINE, BITUMINOUS SURFACE, <br />OR GROUND SURFACE UNLESS <br />OTHERWISE INDICATED) <br />PROPOSED SILT FENCE <br />PROPOSED DIRECTION OF DRAINAGE <br />PROPOSED RIP -RAP <br />WETLAND FILL <br />(SEE WETLAND REPLACEMENT PLAN <br />FOR QUANTIFICATION OF FILL AREAS) <br />WETLAND RESTORATION AREA <br />(SEE WETLAND REPLACEMENT PLAN <br />FOR DETAILS) <br />WETLAND CREATION AREA <br />(SEE WETLAND REPLACEMENT PLAN <br />FOR DETAILS) <br />PROPOSED INLET PROTECTION <br />PROPOSED WETLAND BUFFER SIGNAGE <br />-- - - - <br />- <br />/ <br />I <br />/ <br />CI <br />WATER MAIN NOTES <br />EXISTING WATER MAIN LOCATION AND SIZE SHALL BE VERIFIED IN THE FIELD <br />PRIOR TO CONSTRUCTION. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO <br />ANY INSTALLATIONS. <br />PROVIDE PIPE INSULATION WHERE SEWER (SANITARY OR STORM) CROSSES <br />WITHIN 18" OF WATER MAIN. <br />PROPOSED WATER MAIN SHALL BE PVC (PRESSURE CLASS AWWA C900 WITH <br />DR RATING OF 18). PROPOSED WATER SERVICE PIPE SHALL BE 1" COPPER <br />TYPE K. <br />TRACER WIRE WILL BE LAID WITH ALL PVC WATER MAINS, VALVE BOXES, AND <br />HYDRANTS. <br />MAINTAIN MINIMUM 7.5 -FT COVER TO TOP OF ALL WATER MAIN PIPE. <br />Zoned R-1 <br />28-31-22-31-0011 <br />Owner. Gary & Sharia Foster <br />SANITARY SEWER NOTES <br />EXISTING SANITARY SEWER LOCATION, SIZE, AND ELEVATION SHALL BE VERIFIED <br />IN THE FIELD PRIOR TO CONSTRUCTION. NOTIFY ENGINEER OF ANY <br />DISCREPANCIES PRIOR TO ANY INSTALLATIONS. <br />PROPOSED SANITARY SEWER MAIN SHALL BE PVC SDR 35 AND SDR 26. <br />PROPOSED SANITARY SEWER SERVICES SHALL BE 4" PVC SDR 26. <br />Zoned R-1 <br />28-31-22-31-0028 <br />Owner. Jess & Rebecca Roering <br />992 Aspen Lane <br />1 I1-_ <br />1 <br />1'Y;I <br />I;• I I L; <br />._1 1 <br />Zoned R-1 <br />A <br />•-I 28-31-22-31-0028 i <br />Owner. Susan M. Schmitz Revocable Trust <br />998 Aspen Lane <br />1 1 <br />Know what's below. <br />Call before you dig. <br />8-4 r- r. <br />Li L.1%I•`N •iII <br />1\11 <br />iiiiLi Li Li i . <br />Zoned R-1 <br />J <br />sig <br />u <br />25 <br />25 <br />!Y_ <br />12 / <br />BLOCK 4 <br />+ f•YA*sl.++ + <br />LA <br />1 <br />J <br />i <br />it <br />K '5 <br />--R <br />\ <br />G <br />Osvo N <br />SOUTHWEST CORNER OF THE <br />iE 1/4 OF THE SW 1/4 --- <br />SECTION 28, TVA.. 31, RGE. 22 <br />A <br />Zoned PUD (Ord. 26-04) <br />/ <br />2 <br />BLO <br />1: J <br />u <br />1 <br />3 <br />L <br />P,POpOSF��r`O%' <br />COQ <br />SF <br />RV4T1O <br />N,y,p <br />Fry <br />\ _ <br />i \ F- `I,Y F4 <br />NQ -• . c v <br />IOU , , \ 1 <br />\\ \ <br />\ \N <br />N N <br />N N <br />OUTLOT E3 <br />Zoned PUD (Ord. 28-04) <br />564 ttp P° <br />Zoned Rural <br />0 <br />WITNESS CORNER, SECTION 33, ' <br />TWP. 31, RGE 22 <br />TITLE SHEET, NOTES & LEGEND <br />SADDLE CLUB P.U.D. <br />DRAWN BY: <br />C.M. <br />DESIGN BY: <br />C.W.P. <br />CHCKD BY: <br />C.W.P. <br />PROJ. NO. <br />13-1414 <br />ORIGINAL DATE: <br />OCTOBER 14, 2013 <br />REVISION DESCRIPTION <br />0 <br />w <br />0 <br />0 <br />J <br />J <br />0 <br />0 <br />z <br />0 <br />w <br />0 <br />z <br />w <br />J <br />J <br />Ll <br />0 <br />z <br />J <br />1- <br />RCWD RE -SUBMITTAL <br />0 <br />N <br />CD <br />L.11 <br />1- <br />1 - <br />UJ <br />J <br />1- <br />z <br />w <br />2 <br />2 <br />0 <br />0 <br />0 <br />0 <br />FINAL PLAT SUBMITTAL <br />w <br />1- <br />0 <br />M <br />M <br />M <br />N <br />N <br />sr <br />N <br />N <br />sr <br />N <br />LC) <br />CI) <br />E <br />�E� <br />as L <br />CO <br />ami AaAr� <br />L "0 <br />C c <br />CO <br />CO c C <br />.2 w <br />cn <br />c• <br />c <br />-m 0 <br />U � U <br />O <br />co a) <br />>* CD <br />E c <br />>•.. D •U <br />C <br />0) >, <br />N s_ 5 <br />-c <br />cd <br />0 <br />to <br />0) <br />c <br />c <br />0 <br />a) <br />co <br />0) <br />4) <br />E) <br />to <br />(0 <br />05.21.2014 <br />w <br />0 <br />SADDLE CLUB P.U.D. <br />E <br />cog <br />r <br />TITLE SHEET, NOTES & LEGEND <br />PREPARED FOR: <br />DUPONT <br />HOLDINGS, LLC <br />1101)0 <br />SITE PLANNING <br />& ENGINEERING <br />PLOWE <br />ENGINEERING, INC. <br />6776 LAKE DRIVE <br />SUITE 110 <br />LINO LAKES, MN 55014 <br />PHONE: (651) 361-8210 <br />FAX: (651) 361-8701 <br />NORTH <br />1► <br />0 50 100 <br />1 INCH =100 FEET <br />CO <br />