Laserfiche WebLink
7300 WEST 147TH STREET SUITE 504 APPLE VALLEY, MN 55124-7580 (952) 431-4433 <br />MEMORANDUM: <br />PROJECT: <br />CNH NO: <br />DATE: <br />TO: <br />SUBJECT: <br />Lino Lakes Fire Station <br />14045 <br />February 24, 2015 <br />City of Lino Lakes - Mayor and City Council <br />Alternate #5 Background Information <br />027 <br />The following is a summary of the information related to review of Alternate #5 High Speed Coiling <br />Doors instead of Four -Fold Doors for City Council consideration for the Lino Lakes Fire Station <br />project. CNH Architects has provided additional review and information for use by the City Council <br />in considering this item. <br />Alternate #5 is a deduct to provide high speed coiling doors at the apparatus bays instead of four -fold <br />doors indicated in the base bid. The four -fold door system was designed originally as the only <br />approach for this project but the high-speed coiling doors were added as requested during the bidding <br />process as an alternate for consideration by Council. <br />Operation: <br />Both doors systems provide the operational benefits that are important for a fire station, quick <br />opening and closing allowing for faster response time and less risk of fire apparatus hitting the door <br />in the urgency of leaving the building on a call. Slower opening sectional overhead doors are much <br />more likely to be hit damaging the door and apparatus. While four -fold doors are easier to operate <br />manually in the case of a power failure than high speed coiling, this is not an issue for this facility <br />since the doors will be connected to the emergency backup generator. <br />Maintenance: <br />In our opinion, the maintenance on both door types should be very low. We have installed five four- <br />fold doors at the Roseville Fire Station and they have been very pleased with their operation for the <br />past 18 months of operation. We have also installed high-speed coiling doors at an auto dealership (a <br />common use of this door type) and the record for low -maintenance operation is very good as well. <br />CNH Architects is also aware of concerns that the Eagan Fire Department has had with the four -fold <br />doors that were installed at their Fire Safety Center where they have had a lot of adjustments and <br />several maintenance issues. It is hard to determine how representative the Eagan project is as the <br />doors were specified incorrectly by that projects design firm, disassembled totally twice for factory <br />painting, reassembled each time and then reinstalled. There are over 20 fire stations in the Twin <br />Cities that have four -fold door installations while high-speed coiling doors have not been installed <br />locally in any fire stations. They have however been installed in dozens of other uses locally include <br />many auto dealerships as noted earlier as well as fire stations in other parts of the country. <br />Energy Efficiency: <br />The four -fold door and high-speed coiling doors have been compared for their thermal values. Four- <br />fold doors have a typical U -value of 0.45 for a door based on an insulated door panel and 1" <br />P:\PROJECTS\2014\14045\4 - BIDDING\ALTERNATE #5 RECOMMENDATIONS.DOCX <br />