My WebLink
|
Help
|
About
|
Sign Out
Home
Search
07-27-2015 Council Packet
LinoLakes
>
City Council
>
City Council Meeting Packets
>
1982-2020
>
2015
>
07-27-2015 Council Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/8/2015 1:11:18 PM
Creation date
8/21/2015 10:16:38 AM
Metadata
Fields
Template:
City Council
Council Document Type
Council Packet
Meeting Date
07/27/2015
Council Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OE <br />C.S.A.H. NO. 21) <br />CENTERVILLE ROAD <br />3, 10 <br />520 LF 4" PERF. <br />DRAINTILE _ <br />INV: 906.50 <br />Property Line <br />c <br />Proposed Property Line (s.0' ROW) <br />UTILITY NOTES <br />1. It is the responsibility of the contractor to perform or coordinate all necessary utility connections and <br />relocations from existing utility locations to the proposed building, as well as to all onsite amenities. <br />These connections include but are not limited to water, sanitary sewer, cable TV, telephone, gas, <br />electric, site lighting, etc. <br />2. All service connections shall be performed in accordance with state and local standard <br />specifications for construction. Utility connections (sanitary sewer, watermain, and storm sewer) <br />may require a permit from the City. <br />3. The contractor shall verify the elevations at proposed connections to existing utilities prior to any <br />demolition or excavation. <br />4. The contractor shall notify all appropriate engineering departments and utility companies 72 hours <br />prior to construction. All necessary precautions shall be made to avoid damage to existing utilities. <br />5. Storm sewer requires testing in accordance with Minnesota plumbing code 4715.2820 where <br />located within 10 feet of waterlines or the building. <br />6. All RCP pipe shown on the plans shall be MN/DOT class 5. <br />SAN MH1 <br />(BY CITY) <br />RIM=912.30* <br />INV=904.00* <br />OE <br />- CB -1 <br />RI M=912.52 <br />INV=910.00 <br />SUMP=907.00 <br /><S. <br />FES <br />I NV=908.55 <br />CONNECT TO WYE <br />PROVIDED BY CITY <br />INV=904.47* <br />/ <br />/ <br />/ <br />/ <br />NEW SANITARY <br />43 LF 6" PVC (D <br />SERVIC <br />CB -2 <br />RI M=912.47 <br />INV=908.45 <br />SUMP=905.45 <br />65 LF 12" <br />RCP @ 0.7% <br />FES <br />UTILITY NOTES <br />7. Maintain a minimum of 7'/2 of cover over all water lines and sanitary sewer lines. Install water <br />lines 18" above sanitary sewers, where the sanitary sewer crosses over the water line, install <br />sewer piping of materials equal to watermain standards for 9 feet on both sides and maintain 18" <br />of separation. <br />8. Where 7''A' of cover is not provided over sanitary sewer and water lines, install 2" rigid <br />polystyrene insulation (MN/DOT 3760) with a thermal resistance of at least 5 and a compressive <br />strength of at least 25 psi. Insulation shall be 4' wide, centered over pipe with 6" sand cushion <br />between pipe and insulation. Where depth is less than 5', use 4" of insulation. <br />9. All watermain piping shall be class 52 ductile iron pipe unless noted otherwise. <br />10. See Project Specifications for bedding requirements. <br />11. Pressure test and disinfect all new watermains in accordance with state and local requirements. <br />12. Sanitary sewer piping shall be PVC, SDR -35 for depths less than 12', PVC SDR -26 for depths <br />between 12' and 26', and class 52 D.I.P. for depths of 26' or more. <br />13. All new manholes, catch basins, and catch basin / manhole structures shall be constructed <br />utilizing an external chimney seal that is capable of providing a sound seal from casting to <br />pre -cast section. Chimney seals shall be Infi-shield Uni-band or an approved equal. <br />14. Install water and fire service inside the building and terminated 12" above finished floor with a <br />blind flange. <br />_ _ - - S89°24'11 "E - 1254_95 <br />OE OE <br />- INV=908.00 - - <br />r <br />OE <br />o€ e <br />-- <br />- - NEW 24" CULVERT <br />(BY CITY) <br />FES (BY CITY) <br />INV=903.15* <br />LEGEND <br />O <br />0 <br />Ct <br />STORM MANHOLE <br />CATCH BASIN <br />CURB INLET <br />FLARED END <br />SANITARY MANHOLE <br />HYDRANT <br />GATE VALVE & BOX <br />® WATER SHUTOFF <br />: LIGHT POLE <br />REET <br />(C.S.A.H. NO. 34 <br />MITERED END GRATE <br />W/ 4'X4' SCOURSTOP <br />INV=903.80 <br />FES <br />INV=905.45 <br />C6 <br />COORD. W/MECH. <br />INV=909.50* <br />380 LF 4" PERF. <br />DRAINTILE <br />INV: 906.50 <br />1- <br />0 <br />DT <br />MITERED END GRATE <br />W/ 4'X4' SCOURSTOP <br />INV=906.50* <br />*COORDINATE OUTLET WITH <br />WETLAND MITIGATION BY OTHERS <br />9.6% <br />FES <br />INV=908.05 <br />15 LF 10"PVC @1.0% <br />STMH1 <br />INV=908.35 <br />COORD. W/MECH. <br />INV=908.50* <br />PROPOSED FIRE STATION <br />FFE = 914.50' <br />75 LF 12" PVC @ 0.40% <br />' « <br />H <br />1.- <br />o <br />U , >- <br />co <br />m z <br />I z 2 <br />>-w <br />5' (ARCH 100') <br />50 LF 4" PVC @ 0.20% <br />INV= 908.10', OUTLET= 908.00' <br />45 LF 4" PVC @ 0.89% <br />INV= 908.40', OUTLET= 908.00' <br />vqe'- CB -5 <br />RIM=911.03 <br />INV=908.23 <br />SUMP=905.23 <br />WE-(\ PND <br />wet <br />COORD. W/MECH. <br />(SEE NOTE 14) <br />4'X4' SCOURSTOP <br />MAT AT EACH OUTLET <br />160 LF 4" PERF. <br />DRAINTILE <br />INV: 903.80 <br />wet <br />15LF12" OE <br />RCP @ 0.5% <br />G <br />CTV <br />OE <br />UE <br />FO <br />G <br />T <br />T <br />I I <br />DT m <br />CABLE UNDERGROUND LINE <br />ELECTRIC OVERHEAD LINE <br />ELECTRIC UNDERGROUND LINE <br />FIBER OPTIC UNDERGROUND LINE <br />NATURAL GAS UNDERGROUND LINE <br />SANITARY SEWER PIPE <br />STORM SEWER PIPE <br />TELEPHONE UNDERGROUND LINE <br />WATERMAIN PIPE <br />DRAINTILE PIPE <br />- - - - PROPERTY LINE <br />SETBACK LINE <br />DELINEATED WETLAND (BY OTHERS) <br />FLOODPLAIN <br />BASE BID / BID ALTERNATE LIMITS <br />CB -9 <br />RI M=908.05 <br />- INV=905.52 - <br />SUMP=903.52 <br />30 LF 15"RCP @1.0% <br />\ <br />FES (BY CITY) <br />I NV=906.11 * <br />24" CULVERT <br />(BY CITY) <br />CB -3 <br />RIM=911.71 <br />INV=908.47 <br />SUMP=905.47 <br />SAN MH2 (BY CITY) <br />RIM=912.18* <br />INV=905.30* <br />NEW DOMESTIC <br />WATER SERVICE <br />80 LF 4" DIP <br />6" X 6" MJ TEE <br />6" GV W/BOX <br />NEW FIRE WATER SERVICE <br />80 LF 6" DIP <br />470 LF 4" PERF. <br />DRAINTILE <br />INV: 906.50 <br />1 DT <br />30 LF 15" RCP @ 0.5% 750 LF 4" <br />DRAINTILE <br />4 <br />C6 <br />INSTALL 20 LF 4" SOLID PVC <br />PIPE AT WATERMAIN CROSSING <br />CONNECT TO STUBS <br />PROVIDED BY CITY <br />P\N B� C\ -CN(/ <br />1/ <br />/ a� <br />' FES (BY CITY) <br />( <br />INV=906.00* <br />I <br />1 <br />▪ 1,111, <br />I <br />I <br />P:\Projects\ rojec <br />to0 <br />o <br />J <br />iv <br />a <br />0 <br />/ac 030 <br />61) <br />co <br />SANITARY SEWER AND <br />WATERMAIN STUBS BY CITY <br />CB -4 <br />RI M=911.71 <br />INV=908.71 <br />SUMP=905.71 <br />CONNECT DRAINTILE <br />TO CATCH BASIN <br />(TYP BOTH SIDES) <br />MITERED END GRATE <br />W/ 4'X4' SCOURSTOP <br />INV=906.00 <br />Cb <br />INSTALL 20 LF 4" SOLID PVC PIPE <br />AT WATERMAIN CROSSING <br />s - 2014\12146115- Lino Lakes Fire Station\C. Design\Drawing Files\12146115 C4.dwg <br />S89°24'11 "E 700.16 <br />CB -6 <br />RIM=911.03 <br />INV=908.38 <br />SUMP=905.38 <br />CONNECT DRAINTILE <br />TO CATCH BASIN <br />(TYP BOTH SIDES) <br />GPoSN <br />\ON O <br />FPF-� <br />��02Oo <br />l 5Cp� <br />lI <br />q2 <br />PckO-\ \,o <br />l0o5Ne11 <br />P- PP0 <br />111, .110 <br />IN <MD <br />CB -7 <br />RIM=910.34 <br />INV=906.70 <br />SUMP=903.70 <br />CB -8 <br />RIM=910.34 <br />INV=907.00 <br />SUMP=904.00 <br />II I <br />II I <br />By City <br />By General Contractor <br />CB -10 <br />RIM=908.05 -� <br />INV=905.72 <br />SUMP=903.72 <br />CONNECT DRAINTILE <br />TO CATCH BASIN <br />(TYP BOTH SIDES) <br />40 LF 12" .�►�� <br />RCP @0.5% % <br />/ <br />/ <br />/ <br />I/ <br />260 LF 4" <br />DRAINTILE <br />Iz <br />w <br />2 <br />Iw <br />Iw <br />0 <br />z <br />I.5 <br />J <br />Iw <br />III I <br />111 I <br />III <br />CONNECT DRAINTILE <br />TO CATCH BASIN <br />(TYP BOTH SIDES) <br />1/ <br />/// <br />%/ <br />// <br />/// <br />/// <br />/1/ <br />/// <br />/i// / <br />/1 <br />// <br />1! <br />ee, <br />VARIABLE <br />APPROXIMATE FLOODPLAIN <br />903.58 PER RCWD <br />as <br />5" <br />VARIABLE <br />4'-0" TYPICAL <br />O <br />OE OE <br />MANHOLE FRAME & COVER: <br />NEENAH R-2501, TYPE C GRATE <br />MIN OF 2, MAX OF 5 CONCRETE <br />ADJUSTMENT RINGS WITH FULL <br />BED OF MORTAR BETWEEN EACH AND <br />A 4" COLLAR ON THE OUTSIDE. NO SHIMS <br />OF ANY MATERIAL ALLOWED. <br />PLACE EXTERNAL CHIMNEY SEAL. <br />% 6" PRECAST REINFORCED <br />CONCRETE SLAB. <br />SEAL WITH 2 BEADS OF RAM-NEK. <br />ALL JOINTS IN MANHOLE TO HAVE <br />'0' RING RUBBER GASKETS. <br />MANHOLE STEPS, COPOLYMER <br />POLYPROPYLENE PLASTIC, <br />WITH 1/2" GRADE 60 STEEL <br />REINFORCEMENT OR EQUAL, 16" O.C. <br />PRECAST CONCRETE SECTION <br />PIPE SHALL BE CUT OUT FLUSH <br />WITH INSIDE FACE OF WALL. <br />WATERTIGHT CONNECTION <br />(BOOT, TYPICAL) <br />O <br />O <br />REINFORCE WITH #4 <br />REBAR @ 8" E.W. <br />SECTION <br />STORM SEWER JUNCTION <br />MANHOLE DETAIL <br />NOT TO SCALE <br />D <br />NORTH <br />0 20 40 80 <br />REVISIONS: <br />0 <br />0 <br />0) <br />a) <br />0 <br />U) <br />N <br />0) <br />0 <br />z <br />Lu <br />Eric G. Meyer, P.E. <br />DATE 01/19/15 <br />COMM: 12146115 <br />01/19/15 <br />Addendum No. 2 <br />LO <br />N <br />Watershed Submittal <br />LO <br />C) <br />CD <br />Watershed Comments <br />N <br />Watershed Revs <br />LO <br />Watershed Revs <br />M <br />0 <br />10 <br />N) <br />N <br />0, <br />rn <br />0 <br />00 <br />10 <br />4 <br />N <br />10 <br />10 <br />SUITE 504 APPLE VALLEY, MN <br />as <br />0 <br />\V <br />V J <br />0 <br />LL <br />Lino Lakes <br />1710 Birch Street <br />Lino Lakes, Minnesota <br />Utility Plan <br />0 <br />0 <br />ci <br />z <br />5 <br />x <br />(0)- <br />F F <br />O <br />
The URL can be used to link to this page
Your browser does not support the video tag.