Laserfiche WebLink
CORROSION CONTROL CONSULTANTS & LABS, INC. a GPI company <br />ANALYTICAL LABORATORY REPORT <br />Tuesday. May 20. 2014 <br />Page 3 of 3 <br />CUSTOMER.: KLM Engineering, Inc. <br />PO Box 897, 3394 Lake Elmo Ave N <br />Lake Elmo, MN 55042 <br />DATE RECEIVED: <br />PO/PROJECT #: <br />SUBMITTAL#: <br />Thursday, May 15, 2014 <br />MN 3192 <br />2014-05-15-008 <br />Unless otherwise noted, the condition of each sample was acceptable upon receipt, all laboratory quality control requirements <br />were met, and sample results have not been adjusted based on field blank or other analytical blank results- Individual sample <br />results relate only to the sample as received by the laboratory. <br />�,',A �Jason Kraai <br />Tests Reviewed By: Jason Kraai, Senior Analyst _ 2014.05.20 <br />CCC&L has obtained accreditation under the following programs: —17:08:5 / -0400' <br />• National Lead Laboratory Accreditation Program (NLLAP) <br />ELLAP: AIHA Laboratory ELLAP Accreditation Program Laboratory, 1D#101030 (www.aiha.oro) <br />OH: Ohio Department of Health Lead Poisoning Prevention Program, Approval #E10013 (www.odh.ohio.gov) <br />AIWA Laboratory IHLAP Accreditation Program (www.aiha.orq) <br />IHLAP; Laboratory ID#101030 <br />• National Environmental Laboratory Accreditation Program (NELAP) <br />NY: State of New York Department of Health, Laboratory ID#11609 (Serial # 50712, 50714-50716, 51157) (51 6-485-5570) <br />LA: State of Louisiana Department of Environmental Quality, Laboratory ID#180321 (Certificate 05036) ( www.deo.louisiana.Qov) <br />OK: Oklahoma Department of Environmental Quality, Laboratory ID#9993 (Certificate 2013-040) (www degstate_ok.us) <br />Testing which is performed by CCC&L according to test methods, or for elements which are not included in the table below fall outside of the <br />current scope of laboratory accreditation. Customers are encouraged to verify the current accreditation status with the individual accreditation <br />programs by calling or visiting the appropriate website for the applicable program. <br />Air and Emissions <br />Element/Test <br />Suspended Particulates: PM10 / TSP <br />Lead in Airborne Dust <br />Lead in Airborne Dust <br />Metals in Airborne Dust <br />Surface Coating- Density <br />Surface Coating: Percent Solids <br />Surface Coating: Percent Water <br />Surface Coating: Volatile Content <br />Solid Chemical Materials <br />Eleinent/Test <br />TCLP <br />Lead in Soil <br />Lead in Paint <br />Lead in Paint <br />Lead in Dust Wipes <br />Lead in Dust Wipes <br />Ignitability <br />SCOPE OF ACCREDITATION <br />Method <br />40 CFR 50 Appendix J / 40 GFR 50 Appendix B <br />NIOSH 7300 <br />EPA 600/R-93/200/ EPA 6010C <br />EPA 600/R-93/200/ NIOSH 7300/ EPA 6010C <br />ASTM D1475 <br />ASTM D2697 <br />EPA 24 <br />EPA 24 / ASTM 02369 <br />Method <br />EPA 1311(Sample Preparation Method) <br />EPA 3050B/ EPA 6010C <br />EPA 3050B/ EPA 6010C <br />ASTM D 3335-85A/ EPA 60100 <br />EPA3050B/ EPA6010C <br />EPA 600/R-93/200/ EPA 60100 <br />EPA 1010A <br />Non -Potable Water / Analysis by ICP <br />Element/Test Method Accreditation(s) <br />Arsenic EPA 6010C/ EPA 200.7 Rev 4.4 <br />Barium EPA 6010C/ EPA 200.7 Rev 4.4 <br />Cadmium EPA 6010C/ EPA 200.7 Rev 4.4 <br />Chromium EPA 6010C/ EPA 200.7 Rev 4.4 <br />Copper EPA 6010C/ EPA 200.7 Rev 4.4 <br />Lead EPA 6010C/ EPA 200.7 Rev 4.4 <br />Mercury EPA245.1 Rev.3/ EPA7470A <br />Nickel EPA 6010C/ EPA 200.7 Rev 4.4 <br />Selenium EPA 6010C/ EPA 200.7 Rev 4.4 <br />Silver EPA 6010C/ EPA 200.7 Rev 4.4 <br />Zinc EPA 6010C/ EPA 200.7 Rev 4.4 <br />Cobalt --- <br />Manganese <br />Acid Digestion EPA 3010A NY, LA <br />NY, LA, OK <br />NY, LA, OK <br />NY, LA, OK <br />NY, LA, OK <br />NY, LA, OK <br />NY, LA, OK <br />NY, LA, OK <br />NY, LA, OK <br />NY, LA, OK <br />NY, LA, OK <br />NY, LA, OK <br />Accreditation(s) <br />NY, LA <br />ELLAP, 01-1, NY, LA <br />ELLAP, OLI <br />IHLAP <br />NY <br />NY <br />NY <br />NY <br />Accreditation{sl <br />NY, LA, OK <br />ELLAP, OH, NY, LA, OK <br />ELLAP, OH, NY, LA <br />NY <br />NY, LA <br />ELLAP, OH <br />NY <br />Solid Chemical Materials <br />Method Accreditation(s) <br />NY <br />NY <br />NY <br />NY <br />NY <br />NY, LA, OK <br />NY <br />NY <br />NY <br />NY <br />NY <br />NY <br />NY <br />NY, LA <br />EPA 60100 <br />EPA 6010C <br />EPA 6010C <br />EPA 6010C <br />EPA 6010C <br />EPA 601OC <br />EPA 6010C <br />EPA 6010C <br />EPA 6010C <br />EPA 6010C <br />EPA6010C <br />EPA 6010C <br />EPA 601 OC <br />EPA 3050B <br />Tliis report shall not be reproduced except in full, without written approval of CCC&L. <br />4403 Danker CT SE Kentwood, MI 49512-4054 - (616) 940-3112 • www.ccclabs.cum . www_gpinet.com <br />